Example: Integrated Photonic Line Card in a Metro Linear Packet Optical Configuration
This example shows how to configure Junos OS to support the integrated photonic line card (IPLC) base modules in a Metro linear packet optical configuration.
Requirements
This example uses the following hardware and software components:
Four IPLC base modules
Compatible 10-Gigabit or 100-Gigabit Ethernet OTN PICs. For a list of compatible optical interfaces that are compatible with the IPLC ports, see PTX Series IPLC Compatibility.
Three PTX3000 Packet Transport Routers running Junos OS 15.1F6
For complete information on all PTX Series Packet Transport Routers hardware components, see PTX Series Packet Transport Routers.
For complete information on all PTX Series Packet Transport Routers software features, see Junos OS for PTX Series Packet Transport Routers, Release 15.1.
Overview
This examples describes how to configure Junos OS to support
IPLC base modules in a metro linear packet optical deployment. The Add and Drop ports of the IPLC modules
are physically connected to interfaces housed in the same PTX3000
chassis.
Topology
Figure 1 shows the configuration of the IPLC modules and interfaces for this example.

This procedure describes how to configure Junos OS for the IPLC modules. This is not a complete configuration and does not include full instructions for configuring the router or the associated line cards. Before you start this procedure, complete the following hardware and software tasks on the PTX3000 router:
Install the IPLC modules, associated line cards, and PICs into the PTX3000 chassis so that the hardware configuration matches what is shown in Figure 1. If you need to make changes to the positions of the cards in the chassis, adjust the FPC numbers referenced in Figure 1 and configure them accordingly.
Best Practice We recommend that you place the two IPLC modules at Node B into the same FPC/PIC slot pair on the PTX3000 chassis. In this example the IPLCs at Node B are located in FPC slots 2 and 3.
Configure the associated wavelengths on the interfaces of the PTX3000 by using the following procedure:
Specify the interface to configure.
[edit]user@host# edit interfaces interface-name]For example:
[edit]user@host# edit interfaces et-6/0/0]Specify the wavelength value supported on the interface.
[edit interfaces et-6/0/0]user@host# set wavelength
Note Be sure to specify wavelength values on each interface as shown in Figure 1. If you must adjust the wavelength values, make sure that you enter a value supported on the IPLC. For information on the wavelengths supported by the IPLC, see Understanding the Integrated Photonic Line Card Architecture.
Make all connections to and from the PICs in the PTX3000 chassis to the
AddandDropports on front panel of each IPLC node as shown in Figure 1.Connect your fiber pairs to the
Line INandLine OUTports on the front panel of each IPLC node as shown in Figure 1.For simplicity, Figure 1 does not show the optical ILAs between the three IPLC nodes.
On Node B, connect the two IPLC modules together using the
PT INandPT OUTports on the front panel of the IPLC as shown in Figure 1.
Anytime you need to disconnect or connect the
fiber span from the Line IN and Line
OUT ports on the IPLC module, we recommend you disable
the optical supervisory channel and the erbium-doped fiber amplifiers
on the IPLC.
Always refer to the PTX3000 Packet Transport Router Hardware Guide when connecting or disconnecting cables on the IPLC modules. See PTX3000 Packet Transport Router Hardware Guide.
This example results in the following configuration:
Table 1: Example Configuration Summary
Wavelength | Node A | Node B | Node C | |||
|---|---|---|---|---|---|---|
Optical Interface Waveform is Switched to on PTX3000 Chassis | IPLC Slot: Port: Mode: | Optical Interface Waveform is Switched to on PTX3000 Chassis | IPLC Slot: Port: Mode: | Optical Interface Waveform is Switched to on PTX3000 Chassis | IPLC Slot: Port: Mode: | |
1554.54 | — | — | et-8/0/4 | Slot: 2 Port: 8 Mode: switch | et-10/0/2 | Slot: 8 Port: 8 Mode: switch |
1556.15 | et-12/0/3 | Slot: 1 Port: 6 Mode: switch | — | Slot: 2 Port: 6 Mode: wss-express-in(bypass) Slot: 3 Port: 6 Mode: wss-express-in(bypass) | et-10/0/3 | Slot: 8 Port: 6 Mode: switch |
1556.96 | et-12/0/2 | Slot: 1 Port: 5 Mode: switch | et-8/0/3 | Slot: 3 Port: 5 Mode: switch | — | — |
1560.20 | et-12/0/1 | Slot: 1 Port: 1 Mode: switch | et-6/0/2 et-8/0/2 | Slot: 2 Port: 1 Mode: switch Slot: 3 Port: 1 Mode: switch | et-10/0/1 | Slot: 8 Port: 1 Mode: switch |
1561.01 | et-12/0/0 | Slot: 1 Port: 0 Mode: switch | et-6/0/1 et-6/0/0 | Slot: 2 Port: 0 Mode: switch Slot: 3 Port: 0 Mode: switch | et-10/0/0 | Slot: 8 Port: 0 Mode: switch |
Configuration
The following example requires you to navigate various levels in the configuration hierarchy.
For information about navigating the CLI, see Using the CLI Editor in Configuration Mode.
Before you start this procedure, be sure to complete the tasks described in the Topology section of this example.
To configure the IPLC base modules in this example, perform these tasks:
CLI Quick Configuration
To quickly configure the IPLC modules in this example, copy the following commands into a text file, remove any line breaks, and then paste the commands into the CLI at the [edit] hierarchy level.
Configuring the IPLC Base Module at Node A
Step-by-Step Procedure
This procedure describes how to configure the IPLC base module in slot 1 of Node A in this example.
Before you start this procedure, be sure to complete the tasks described in the Topology section of this example.
To configure the IPLC base module in slot 1 of Node A:
- Specify the slot location of the IPLC base module in Node
A and access the IPLC configuration hierarchy.[edit]user@host# edit chassis fpc 1 optical-options
- Configure wavelength 1561.01 on port 0 of the IPLC base
module to be switched to optical interface et-12/0/0.[edit chassis fpc 1 optical-options]user@host# set wavelength 1561.01 switch et-12/0/0
- Configure wavelength 1560.20 on port 1 of the IPLC base
module to be switched to optical interface et-12/0/1. [edit chassis fpc 1 optical-options]user@host# set wavelength 1560.20 switch et-12/0/1
- Configure wavelength 1556.96 on port 5 of the IPLC base
module to be switched to optical interface et-12/0/2. [edit chassis fpc 1 optical-options]user@host# set wavelength 1556.96 switch et-12/0/2
- Configure wavelength 1556.15 on port 6 of the IPLC base
module to be switched to optical interface et-12/0/3.[edit chassis fpc 1 optical-options]user@host# set wavelength 1556.15 switch et-12/0/3
Results
Confirm the configuration of the IPLC modules for Node A. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration.
wavelength 1556.15 {
switch {
et-12/0/3;
}
}
wavelength 1556.96 {
switch {
et-12/0/2;
}
}
wavelength 1560.20 {
switch {
et-12/0/1;
}
}
wavelength 1561.01 {
switch {
et-12/0/0;
}
}
If you are done configuring the device, enter commit from configuration mode.
Configuring the Two IPLC Base Modules at Node B
Step-by-Step Procedure
This procedure describes how to configure the IPLC base module in slot 2 of Node B in this example.
Before you start this procedure, be sure to complete the tasks described in the Topology section of this example.
We recommend that you place the two IPLC modules in the same FPC/PIC slot pair on the PTX3000 chassis.
To configure the IPLC base module in slot 2 of Node B:
- Specify the slot location of the IPLC base module and
access the IPLC configuration hierarchy.[edit]user@host# edit chassis fpc 2 optical-options
- Create a logical connection between this IPLC base module
and the IPLC base module in slot 3.[edit chassis fpc 2 optical-options]user@host# set express-in fpc 3
- Configure wavelength 1561.01 on port 0 of the IPLC base
module in slot 2 to be switched to local optical interface et-6/0/1. [edit chassis fpc 2 optical-options]user@host# set wavelength 1561.01 switch et-6/0/1
- Configure wavelength 1560.20 on port 1 of the IPLC base
module in slot 2 to be switched to local optical interface et-6/0/2.[edit chassis fpc 2 optical-options]user@host# set wavelength 1560.20 switch et-6/0/2
- Configure wavelength 1554.54 on port 8 of the IPLC base
module in slot 2 to be switched to local optical interface et-8/0/4.[edit chassis fpc 2 optical-options]user@host# set wavelength 1554.54 switch et-8/0/4
- Configure wavelength 1556.15 on port 6 of the IPLC base
module in slot 2 to be bypassed: [edit chassis fpc 2 optical-options]user@host# set wavelength 1556.15 wss-express-in
Step-by-Step Procedure
This procedure describes how to configure the IPLC base module in slot 3 of Node B in this example.
Before you start this procedure, be sure to complete the tasks described in the Topology section of this example.
To configure the IPLC base module in slot 3 of Node B:
- Specify the slot location of the IPLC base module and
access the IPLC configuration hierarchy.[edit]user@host# edit chassis fpc 3 optical-options
- Create a logical connection between this IPLC base module
and the IPLC base module in slot 2.[edit chassis fpc 3 optical-options]user@host# set express-in fpc 2
- Configure wavelength 1561.01 on port 0 of the IPLC base
module to be switched to optical interface et-6/0/0. [edit chassis fpc 3 optical-options]user@host# set wavelength 1561.01 switch et-6/0/0
- Configure wavelength 1560.20 on port 1 of the IPLC base
module to be switched to optical interface et-8/0/2. [edit chassis fpc 3 optical-options]user@host# set wavelength 1560.20 switch et-8/0/02
- Configure wavelength 1556.96 on port 5 of the IPLC base
module to be switched to optical interface et-8/0/3.[edit chassis fpc 3 optical-options]user@host# set wavelength 1556.96 switch et-8/0/3
- Configure wavelength 1556.15 on port 6 of the IPLC base
module in slot 3 to be bypassed: [edit chassis fpc 3 optical-options]user@host# set wavelength 1556.15 wss-express-in
Results
Confirm the configuration of the IPLC module located in slot 2 of Node B. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration.
wavelength 1554.54 {
switch {
et-8/0/4;
}
}
wavelength 1556.15 {
wss-express-in;
}
wavelength 1560.20 {
switch {
et-6/0/2;
}
}
wavelength 1561.01 {
switch {
et-6/0/1;
}
}
express-in {
fpc {
3;
}
}
If you are done configuring the device, enter commit from configuration mode.
Confirm the configuration of the IPLC module located in slot 3 of Node B. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration.
wavelength 1556.15 {
wss-express-in;
}
wavelength 1556.96 {
switch {
et-8/0/3;
}
}
wavelength 1560.20 {
switch {
et-8/0/2;
}
}
wavelength 1561.01 {
switch {
et-6/0/0;
}
}
express-in {
fpc {
2;
}
}
If you are done configuring the device, enter commit from configuration mode.
Configuring the IPLC Base Module at Node C
Step-by-Step Procedure
This procedure describes how to configure the IPLC base module in slot 8 of Node C in this example.
Before you start this procedure, be sure to complete the tasks described in the Topology section of this example.
Step-by-Step Procedure
To configure the IPLC base module in slot 8 of Node C:
- Specify the slot location of the IPLC base module in Node
C and access the IPLC configuration hierarchy.[edit]user@host# edit chassis fpc 8 optical-options
- Configure wavelength 1561.01 on port 0 of the IPLC base
module to be switched to optical interface et-10/0/0.[edit chassis fpc 8 optical-options]user@host# set wavelength 1561.01 switch et-10/0/0
- Configure wavelength 1560.20 on port 1 of the IPLC base
module to be switched to optical interface et-10/0/1. [edit chassis fpc 8 optical-options]user@host# set wavelength 1560.20 switch et-10/0/1
- Configure wavelength 1554.54 on port 8 of the IPLC base
module to be switched to optical interface et-10/0/2. [edit chassis fpc 8 optical-options]user@host# set wavelength 1554.54 switch et-10/0/2
- Configure wavelength 1556.15 on port 6 of the IPLC base
module to be switched to optical interface et-10/0/3.[edit chassis fpc 8 optical-options]user@host# set wavelength 1556.15 switch et-10/0/3
Results
Confirm the configuration of the IPLC module located in slot 8 of Node C. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration.
wavelength 1554.54 {
switch {
et-10/0/2;
}
}
wavelength 1556.15 {
switch {
et-10/0/3;
}
}
wavelength 1560.20 {
switch {
et-10/0/1;
}
}
wavelength 1561.01 {
switch {
et-10/0/0;
}
}
If you are done configuring the device, enter commit from configuration mode.
Results
Verification
Confirm that the configuration is working properly.
Verifying the Topology of Each IPLC Node
Purpose
Verify the topology of each IPLC node.
Action
Run the show chassis fpc optical-properties topology command with the detail output level at each IPLC node and verify that the following fields match the values listed in Table 1.
Port/Wavelength—Verify that this field lists the proper wavelength values and IPLC port numbers for each node in this example.
State—Verify that the values for this field match what is listed in Table 1 for the mode value of each IPLC port for each node in this example.
Connected To—If the wavelength is being switched, verify that this field lists the correct interface the wavelength is being switched to.
Verify the topology of each IPLC node.
- For example, at IPLC Node A, enter the following. user@host>show chassis fpc optical-properties topology detail fpc-slot 1
IPLC Topology Information Wavelength(nm) / Port / Frequency(THz) State Connected To Express-in Port DOWN NA Expansion Port DOWN NA 1561.01 0 192.05 Switched et-12/0/0 1560.20 1 192.15 Switched et-12/0/1 1559.39 2 192.25 Blocked NA 1558.58 3 192.35 Blocked NA 1557.77 4 192.45 Blocked NA 1556.96 5 192.55 Switched et-12/0/2 1556.15 6 192.65 Switched et-12/0/3 1555.34 7 192.75 Blocked NA 1554.54 8 192.85 Blocked NA 1553.73 9 192.95 Blocked NA 1552.93 10 193.05 Blocked NA 1552.12 11 193.15 Blocked NA 1551.32 12 193.25 Blocked NA 1550.52 13 193.35 Blocked NA 1549.72 14 193.45 Blocked NA 1548.91 15 193.55 Blocked NA 1548.11 16 193.65 Blocked NA 1547.32 17 193.75 Blocked NA 1546.52 18 193.85 Blocked NA 1545.72 19 193.95 Blocked NA 1544.92 20 194.05 Blocked NA 1544.13 21 194.15 Blocked NA 1543.33 22 194.25 Blocked NA 1542.54 23 194.35 Blocked NA 1541.75 24 194.45 Blocked NA 1540.95 25 194.55 Blocked NA 1540.16 26 194.65 Blocked NA 1539.37 27 194.75 Blocked NA 1538.58 28 194.85 Blocked NA 1537.79 29 194.95 Blocked NA 1537.00 30 195.05 Blocked NA 1536.22 31 195.15 Blocked NA
- At Node B, enter the following:user@host> show chassis fpc optical-properties topology detail fpc-slot 2user@host> show chassis fpc optical-properties topology detail fpc-slot 3
- At Node C:user@host> show chassis fpc optical-properties topology detail fpc-slot 8
Meaning
For example, in Step 1for Node A, you can see that the IPLC module in slot 1 includes the following configuration:
Wavelength 1561.01 is switched to optical interface et-12/0/0
Wavelength 1560.20 is switched to optical interface et-12/0/1
Wavelength 1556.96 is switched to optical interface et-12/0/2
Wavelength 1556.16 is switched to optical interface et-12/0/3
This matches what is listed in Table 1 for Node A and confirms the configuration is operating correctly.