This section lists the resolved issues in Junos Space Network Management Platform Release 18.2R1.

For the most complete and latest information about resolved defects, use the Juniper Networks online Junos Problem Report Search application.

  • Custom-created surveillance categories are refreshed during network rescan and Network Monitoring service restart, which results in the number of nodes rolling back to zero. [PR-1238995]

  • Multiple issues are resolved in Security Director Release 17.2R1 by updating third-party software included with Security Director and other applications. Refer to JSA10840 for more information. [PR 1290124]

  • The script /var/www/cgi-bin/parseUserCertificates used to force the parameter import from certificates does not work. The script fails when X.509 certificate parameters are not configured on Junos Space Platform. [PR 1324713]

  • Modifying the SNMP configuration for self-monitoring in Junos Space Platform deactivates the Node Management Agent (NMA) check on all nodes except for the VP node. [PR 1327249]

  • Junos Space nodes keep dropping out of the cluster after configuring multiple sites and activating eth3 interface, resulting in failure of jobs. This issue is caused by the blocking of ports 55201 and 55249. [PR 1332852]

  • Device discovery by using ww Junos OS adapter fails in the eth3 interface setup because the device is not reachable from Junos Space Platform through the eth0 interface. [PR 1333010]

  • Removal of a certificate revocation list (CRL) does not get updated on all application servers. [PR 1347696]

  • Fabric monitoring service does not get updated after reboot of a pure application node. [PR 1349687]

  • When Junos Space Platform is upgraded from Release 17.1 to Release 17.2, an unnecessary rpcbind service runs, and the process is blocked from external access by the Linux firewall. [PR 1354202]

  • If the result of an executed remote procedure call (RPC) exceeds 255 characters, then the RPC execution result is not stored in Junos Space Platform and the job associated with it fails. [PR 1358975]