The following are the known issues in Connectivity Services Director Release 2.1R1. For each entry, the identifier in the PR Number column of Table 2 is the tracking number in the Juniper Networks problem report (PR) tracking system.
Table 2: Known Issues in Connectivity Services Director Release 2.1R1
PR Number | Problem Description |
---|---|
1244763 | In the Topology view, the status of Layer 3 links are not dynamically updated. Workaround: To update the status of the Layer 3 links you must perform a Refresh Topology job manually. |
1258324 | In the Topology view, optical inline amplifiers (ILAs) are displayed on optical links only after a delay of 15 seconds. Workaround: None at present. |
1257863 | While modifying a Layer 3 VPN service if you select a device to associate a policy, the policy is listed only if you have associated the policy with a device at the time of policy creation. Workaround: None at present. |
1238027 | If the AS number is greater than 65535, you must append Route Target or Route Distinguisher values with “L”. Connectivity Services Director fails to recover a service with such Route Target or Route Distinguisher values. Workaround: None at present. |
1241543 | On the Create Service Definition page, the upper limit of MTU is limited to 9216. Workaround: None at present. |
1243315 | A device you deleted while modifying a Layer 3 VPN service appears in the Create Policy page. Workaround: None at present. |
1247227 | A generic error message is displayed if the deployment of a VPLS service with Traffic Type as Transport VLAN fails. The generic error message must be replaced with the following appropriate error message: Specify CVLAN start and CVLAN end values. Workaround: None at present. |
1248119 | While you are modifying a VPLS service, you cannot search on the Site Settings page for an endpoint that is not associated with the service. Workaround: None at present. |
1250579 | If you modify the ASN value on a device, the new ASN value is not updated in the Connectivity Services Director application. Workaround: None at present. |
1255682 | An Ethernet interface, which is a part of an aggregated Ethernet, is listed as user-to-network interface (UNI). Workaround: None at present. |
1259449 | For a modified RSVP LSP service, the View Configuration Change page displays only the modified configuration instead of the displaying the entire configuration. Workaround: To view the entire configuration, you must force-deploy the RSVP LSP service. |
1255005 | If a service template has multiple MD5 key-value rows with different default values and if you attach this service template to a Layer 3 VPN service, the Template Configuration page displays the same default value for each MD5 key-value row. Workaround: While you are creating a service you can modify the default values for each MD5 key-value row. |
1282178 | You cannot modify a service without modifying at least one endpoint. Workaround: From the Service Settings tab, modify the comment and UNI description of any of the endpoint and deploy the service. |
1257293 | In VPLS Service, you cannot search service by its description. This is because the Connectivity Services Director application does not support searching a service by service description. This problem is planned to be fixed in a future release. |