The following are the known issues in Connectivity Services Director Release 2.1R1. For each entry, the identifier in the PR Number column of Table 2 is the tracking number in the Juniper Networks problem report (PR) tracking system.

Table 2: Known Issues in Connectivity Services Director Release 2.1R1

PR Number

Problem Description

1241543

On the Create Service Definition page, the upper limit of MTU is limited to 9216.

Workaround: None at present.

1248119

While you are modifying a VPLS service, you cannot search on the Site Settings page for an endpoint that is not associated with the service.

Workaround: None at present.

1255682

An Ethernet interface, which is a part of an aggregated Ethernet, is listed as user-to-network interface (UNI).

Workaround: None at present.

1259449

For a modified RSVP LSP service, the View Configuration Change page displays only the modified configuration instead of the displaying the entire configuration.

Workaround: To view the entire configuration, you must force-deploy the RSVP LSP service.

1255005

If a service template has multiple MD5 key-value rows with different default values and if you attach this service template to a Layer 3 VPN service, the Template Configuration page displays the same default value for each MD5 key-value row.

Workaround: While you are creating a service you can modify the default values for each MD5 key-value row.

1282178

You cannot modify a service without modifying at least one endpoint.

Workaround: From the Service Settings tab, modify the comment and UNI description of any of the endpoint and deploy the service.

1257293

In VPLS Service, you cannot search service by its description. This is because the Connectivity Services Director application does not support searching a service by service description. This problem is planned to be fixed in a future release.

1287027

Service templates are not recovered if they do not contain the complete hierarchy for the attributes or statements that are configured.

Workaround: Recreate the templates by providing the complete hierarchy. The Connectivity Services Director application needs this information to recover and manage the templates.

1290708

Some interfaces are listed incorrectly under both NNI and UNI tabs. This problem is planned to be fixed in a future release.

1294235

Service Recovery process does not recover unmanaged device details such as loopback IP address and UNI Interface if one of the end points is configured as unmanaged.

1295268

When an IP address with a suffix less than 18 is allocated to a site in an L3VPN service, IP address allocation is not done properly.

For IP addresses to be assigned properly, you must allocate an IP address suffix that is greater than 18.

1298805

When nodes having the same route distinguisher (RD) value is deleted from a service, the route distinguisher value is not deleted from the service.

1299605

When a new node along with path is added during modification of an RSVP full mesh service definition that has custom pattern, an additional LSP configuration is added to the newly added device.

Workaround: Modify the RSVP full mesh service and add a new node without path information. Modify the service and add the path information.

1299976

vlan-list configuration is not pushed to devices that has VLAN normalization configured.

Workaround: Use templates to configure vlan-list instead of vlan-range.

1299969

ACX5000 Series routers do not support the vlan-id all configuration.

Modified: 2017-08-14