    redundancy-group

    Syntax

    redundancy-group group-name {description description;feb slot-number (backup | primary);no-auto-failover;}

    Hierarchy Level

    [edit chassis redundancy feb]

    Release Information

    Statement introduced in Junos OS Release 8.2.

    Description

    On M120 routers only, configure a Forwarding Engine Board (FEB) redundancy group.

    Options

    group-name is the unique name for the redundancy group. The maximum length is 39 alphanumeric characters.

    Other statements are explained separately.

    Required Privilege Level

    interface—To view this statement in the configuration.

    interface-control—To add this statement to the configuration.

     
     