    Configuring the Maximum Number of Bearers

    You configure the maximum bearers to specify an upper limit on the number of bearers allowed at the system level or access point name (APN) level.

    When the total number of active bearers at the system level or APN level reaches the maximum configured limit, the MobileNext Broadband Gateway rejects new bearer requests.

    • Configure the maximum number of active bearers allowed at the system level.
      [edit unified-edge gateways ggsn-pgw MBG1]user@host# set maximum-bearers 5000000
    • For each APN, configure the maximum number of active bearers allowed at the APN level.
      [edit unified-edge gateways ggsn-pgw MBG1 apn-services apns apn-1]user@host# set maximum-bearers 10000