Configuring the CTP Bundle Data Packet Protocol and OAM Port (CTP Menu)
To configure the CTP Bundle Data Packet Protocol using the CTP Menu:
- From the Main Menu, select 5) Node Operations.
- Select 3) Configure network settings.
- Select 6) CTP Bndl Data pkt protocol. The following warning message is displayed.
*** *** You are about to modify a system parameter that will require *** a system reboot when complete. *** *** If you decide to continue, the system will automatically *** reboot upon leaving these menus. *** *** Note: If these parameters are changed incorrectly, *** system may not be reachable via the network *** after the system reboots. *** Are you sure? y[n]:
- When prompted, specify a value for the protocol ID for data packets in the range 2-254. The default value is 46.
To configure a CTP Bndl OAM port (IPv6):
- From the Main Menu, select 5) Node Operations.
- Select 3) Configure network settings.
- Select 7) CTP Bndl OAM port (IPv6).
- When prompted, specify a port number for OAM packets in
the range 2 through 254.
The default value is 16.