Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation  Back up to About Overview 

To set BERTs on ports

Example injecting a BERT toward the IP network

Parameter expected

Parameter choices: Off ToNet ToIf

[ctp_cmd@nova_47 ~ 43]> cmd port se-1/0 diag bert_tx ToNet

Example receiving a BERT from the IP network

Parameter expected

Parameter choices: Off FromNet FromIf

[ctp_cmd@nova_47 ~ 43]> cmd port se-1/0 diag bert_rx FromNet

Example setting the BERT pattern

Parameter expected

Parameter choices: MARK ALT 511 2047 2^15-1 2^20-1 2^23-1 2^29-1 2^31-1 2^4-1

[ctp_cmd@nova_47 ~ 49]> cmd port se-1/0 diag bert_pat 2^15-1

Example injecting a single error into the BERT

[ctp_cmd@nova_47 ~ 50]> cmd port se-1/0 diag bert_inj