The following issues are resolved in Juniper Networks CSO Release 4.0.2.
In a CSO HA environment, ZTP for a tenant added after a virtual route reflector (VRR) recovery remains inconclusive.
Bug Tracking Number: CXU-27340.
In device redundancy mode, while creating a NAT pool, the Routing Instance field is not displayed.
Bug Tracking Number: CXU-25880
On a Dual CPE device, the deployment of the AllSite_AUTONAT_Policy policy fails.
Bug Tracking Number: CXU-25855
The ZTP of an NFX250 device fails.
Bug Tracking Number: CXU-25822.
For some sites, the Configure Site operation fails and the following error message is displayed:
Policy is out of sync between RE and PFE fpc0. Please resync before commit.
Bug Tracking Number: CXU-25808.
While upgrading CSO from Release 3.3.1 to Release 4.0.1, if link-interface or link-name mappings in Redis are lost, the link utilization graph is not displayed.
Bug Tracking Number: CXU-25728.
After you upgrade CSO to Release 4.0.1, you cannot delete tenants that are created in CSO Release 3.3.1.
Bug Tracking Number: CXU-25716.
In CSO Release 4.0.1, the site upgrade fails for sites with vSRX as a CPE device.
Bug Tracking Number: CXU-25713.
The operation to delete tenants fails and the following error is displayed:
PMTask Fail {"status_code": "409", "error_tag": "Refs Exist", "error_message": "Operation can not be completed since the resource is still being referred to. ", "error_app_message": "Delete when resource still referred: [u'/topology-service/termination-point/edea81b3-fc95-4d19-beea-e56ecfce3fb3', u'/topology-service/termination-point/1ba769cc-00d6-4ad3-914e-913cb4d707eb', u'/topology-service/termination-point/a74ff397-6993-437f-ba67-4ef0d57620bc', u'/topology-service/termination-point/b9a5dd21-3025-4cce-b8a9-7df6d32cf51f', u'/topology-service/termination-point/89c9f27d-4f68-4972-9c10-7ab68805d146', u'/topology-service/termination-point/6afba242-6905-4d3e-8295-4b7b5e791fdd', u'/topology-service/termination-point/e627802b-ec97-4343-8f5c-4c53415d3353']", "error_diag": "This error occurs when a resource is attempted for modification or deletion when there are child resources still referring to it. ", "error_code": "40006"}
Bug Tracking Number: CXU-25686.
On an MX Series device, after you apply the stage-2 configuration, the BGP route is hidden.
Bug Tracking Number: CXU-25665.
When you delete an SD-WAN policy, the custom application group associated with the SD-WAN is not deleted.
Workaround: Log in to the device, and delete the custom application group.
Bug Tracking Number: CXU-25657.
On a gateway router, the application identification license and the application signature that are installed are lost.
Bug Tracking Number: CXU-25641.
The activation of an NFX250 as an SD-WAN CPE device with an ADSL or VDSL WAN link fails if you set the global parameter USE_SINGLE_SSH of the device template to False.
Bug Tracking Number: CXU-25573.
After you upgrade CSO from Release 3.3.1 to Release 4.0.1, the widgets are not displayed in the Dashboard.
Bug Tracking Number: CXU-25405.
While you are editing a role, when you clear an object, the implied capabilities that are listed under the object are cleared.
Bug Tracking Number: CXU-25386.
For an Application Quality of Experience (AppQoE) tenant, an SLA profile with only the Throughput parameter is not supported.
Bug Tracking Number: CXU-25378.
The tenant name cannot be the same across different operating companies.
Bug Tracking Number: CXU-25225.
The POP location on the geographical map is incorrect if you do not validate the address while you are creating a POP.
Bug Tracking Number: CXU-25060.
On the Monitor Overview Page page, a green check mark appears even though the operational state of a device that is going through the RMA process is Down, Expected, or RMA.
Bug Tracking Number: CXU-24933.
The site upgrade for a dual CPE site fails because CSO does not support image upgrade.
Bug Tracking Number: CXU-24823.
When you generate reports for operating companies and their tenants, the customized logo is not displayed.
Bug Tracking Number: CXU-24729.
If all the infrastructure VMs are not up, reports cannot be generated.
Bug Tracking Number: CXU-24560.
The class-of-service scheduler configuration does not take effect on the CPE device.
Bug Tracking Number: CXU-20708
After you upgrade a site with an NFX250 device, the monitoring page does not display any data. This is because the telemetry agent is uninstalled during the site upgrade.
Bug Tracking Number: CXU-19455.
CSO might not come up after a power failure.
Bug Tracking Number: CXU-16530