Viewing Real-time Pseudowire PMs

 

Use this procedure to enable and view real-time PMs for pseudowire services on BTI800 Series network elements. The PMs are displayed in both textual and graphical formats.

PSM supports the following PMs for the pseudowire service:

T1 PMs

E1 PMs

SONET PMs

SDH PMs

SATOP PMs

Code Violations - Line

Errored Seconds

Code Violations - Line

Code Violations - Regenerator Section

SATOP Transmitted Byte Count (Total)

Errored Seconds - Line

Severely Errored Seconds

Errored Seconds - Line

Errored Seconds - Regenerator Section

SATOP Received Byte Count (Total)

Severely Errored Seconds - Line

Background Block Error count

Severely Errored Seconds - Line

Severely Errored Seconds - Regenerator Section

SATOP Byte Loss (Total)

Code Violations - Path

Unavailable Seconds

Unavailable Seconds - Line

Unavailable Seconds - Regenerator Section

 

Errored Seconds - Path

Errored Second Ratio

Code Violations - Path

Code Violations - Multiplex Section

 

Severely Errored Seconds - Path

Severely Errored Second Ratio

Errored Seconds - Path

Errored Seconds - Multiplex Section

 

Severely Errored Frame Seconds - Path

Background Block Error Ratio

Severely Errored Seconds - Path

Severely Errored Seconds - Multiplex Section

 

Unavailable Seconds - Path

 

Unavailable Seconds - Path

Unavailable Seconds - Multiplex Section

 
  

Code Violations - Section

Code Violations - VC4 (AU4 mode only)

 
  

Errored Seconds - Section

Errored Seconds - VC4 (AU4 mode only)

 
  

Severely Errored Seconds - Section

Severely Errored Seconds - VC4 (AU4 mode only)

 
  

Severely Errored Frame Seconds - Section

Unavailable Seconds - VC4 (AU4 mode only)

 
  

Code Violations - VT

Code Violations - VC3 (AU3 mode only)

 
  

Errored Seconds - VT

Errored Seconds - VC3 (AU3 mode only)

 
  

Severely Errored Seconds - VT

Severely Errored Seconds - VC3 (AU3 mode only)

 
  

Unavailable Seconds - VT

Unavailable Seconds - VC3 (AU3 mode only)

 
  

Protection Switch Count

Code Violations - Path

 
   

Errored Seconds - Path

 
   

Severely Errored Seconds - Path

 
   

Unavailable Seconds - Path

 
   

Protection Switch Count

 
  1. To enable real-time PMs, right-click on a pseudowire service in the tree view or in the background of a pseudowire service topology view, and select Enable Realtime PMs >Pseudowire

    Real-time PM collection for the pseudowire service is started, and a PM data widget title bar is displayed for each PM collection point. Additionally, a graphical view displaying the PMs pops up on the screen.

  2. Click the PM data widget title bar to show or hide the PM data.
    Figure 1: Real-time PMs
    Real-time PMs
  3. To change the domain (horizontal) scale of the graphs, highlight the desired area by left-clicking and dragging the mouse to highlight the area of focus, and release.

    Repeat until the desired magnification is achieved.

    Note

    You can also change the scale by right-clicking on a graph, and selecting Zoom In>Domain Axis or Zoom Out>Domain Axis. This changes the horizontal scale while keeping the center of the range as the area of focus.

  4. To turn off real-time PMs, right-click the background in the pseudowire services topology window and choose Disable Realtime PMs.