Viewing Real-time Pseudowire PMs
Use this procedure to enable and view real-time PMs for pseudowire services on BTI800 Series network elements. The PMs are displayed in both textual and graphical formats.
PSM supports the following PMs for the pseudowire service:
T1 PMs | E1 PMs | SONET PMs | SDH PMs | SATOP PMs |
---|---|---|---|---|
Code Violations - Line | Errored Seconds | Code Violations - Line | Code Violations - Regenerator Section | SATOP Transmitted Byte Count (Total) |
Errored Seconds - Line | Severely Errored Seconds | Errored Seconds - Line | Errored Seconds - Regenerator Section | SATOP Received Byte Count (Total) |
Severely Errored Seconds - Line | Background Block Error count | Severely Errored Seconds - Line | Severely Errored Seconds - Regenerator Section | SATOP Byte Loss (Total) |
Code Violations - Path | Unavailable Seconds | Unavailable Seconds - Line | Unavailable Seconds - Regenerator Section | |
Errored Seconds - Path | Errored Second Ratio | Code Violations - Path | Code Violations - Multiplex Section | |
Severely Errored Seconds - Path | Severely Errored Second Ratio | Errored Seconds - Path | Errored Seconds - Multiplex Section | |
Severely Errored Frame Seconds - Path | Background Block Error Ratio | Severely Errored Seconds - Path | Severely Errored Seconds - Multiplex Section | |
Unavailable Seconds - Path | Unavailable Seconds - Path | Unavailable Seconds - Multiplex Section | ||
Code Violations - Section | Code Violations - VC4 (AU4 mode only) | |||
Errored Seconds - Section | Errored Seconds - VC4 (AU4 mode only) | |||
Severely Errored Seconds - Section | Severely Errored Seconds - VC4 (AU4 mode only) | |||
Severely Errored Frame Seconds - Section | Unavailable Seconds - VC4 (AU4 mode only) | |||
Code Violations - VT | Code Violations - VC3 (AU3 mode only) | |||
Errored Seconds - VT | Errored Seconds - VC3 (AU3 mode only) | |||
Severely Errored Seconds - VT | Severely Errored Seconds - VC3 (AU3 mode only) | |||
Unavailable Seconds - VT | Unavailable Seconds - VC3 (AU3 mode only) | |||
Protection Switch Count | Code Violations - Path | |||
Errored Seconds - Path | ||||
Severely Errored Seconds - Path | ||||
Unavailable Seconds - Path | ||||
Protection Switch Count |
- To enable real-time PMs, right-click on a pseudowire service
in the tree view or in the background of a pseudowire service topology
view, and select Enable Realtime PMs >Pseudowire
Real-time PM collection for the pseudowire service is started, and a PM data widget title bar is displayed for each PM collection point. Additionally, a graphical view displaying the PMs pops up on the screen.
- Click the PM data widget title bar to show or hide the
PM data.
Figure 1: Real-time PMs - To change the domain (horizontal) scale of the graphs,
highlight the desired area by left-clicking and dragging the mouse
to highlight the area of focus, and release.
Repeat until the desired magnification is achieved.
Note You can also change the scale by right-clicking on a graph, and selecting Zoom In>Domain Axis or Zoom Out>Domain Axis. This changes the horizontal scale while keeping the center of the range as the area of focus.
- To turn off real-time PMs, right-click the background in the pseudowire services topology window and choose Disable Realtime PMs.