Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Viewing Real-time Pseudowire PMs

    Use this procedure to enable and view real-time PMs for pseudowire services on BTI800 Series network elements. The PMs are displayed in both textual and graphical formats.

    PSM supports the following PMs for the pseudowire service:

    T1 PMs

    E1 PMs

    SONET PMs

    SDH PMs

    SATOP PMs

    Code Violations - Line

    Errored Seconds

    Code Violations - Line

    Code Violations - Regenerator Section

    SATOP Transmitted Byte Count (Total)

    Errored Seconds - Line

    Severely Errored Seconds

    Errored Seconds - Line

    Errored Seconds - Regenerator Section

    SATOP Received Byte Count (Total)

    Severely Errored Seconds - Line

    Background Block Error count

    Severely Errored Seconds - Line

    Severely Errored Seconds - Regenerator Section

    SATOP Byte Loss (Total)

    Code Violations - Path

    Unavailable Seconds

    Unavailable Seconds - Line

    Unavailable Seconds - Regenerator Section

     

    Errored Seconds - Path

    Errored Second Ratio

    Code Violations - Path

    Code Violations - Multiplex Section

     

    Severely Errored Seconds - Path

    Severely Errored Second Ratio

    Errored Seconds - Path

    Errored Seconds - Multiplex Section

     

    Severely Errored Frame Seconds - Path

    Background Block Error Ratio

    Severely Errored Seconds - Path

    Severely Errored Seconds - Multiplex Section

     

    Unavailable Seconds - Path

     

    Unavailable Seconds - Path

    Unavailable Seconds - Multiplex Section

     
      

    Code Violations - Section

    Code Violations - VC4 (AU4 mode only)

     
      

    Errored Seconds - Section

    Errored Seconds - VC4 (AU4 mode only)

     
      

    Severely Errored Seconds - Section

    Severely Errored Seconds - VC4 (AU4 mode only)

     
      

    Severely Errored Frame Seconds - Section

    Unavailable Seconds - VC4 (AU4 mode only)

     
      

    Code Violations - VT

    Code Violations - VC3 (AU3 mode only)

     
      

    Errored Seconds - VT

    Errored Seconds - VC3 (AU3 mode only)

     
      

    Severely Errored Seconds - VT

    Severely Errored Seconds - VC3 (AU3 mode only)

     
      

    Unavailable Seconds - VT

    Unavailable Seconds - VC3 (AU3 mode only)

     
      

    Protection Switch Count

    Code Violations - Path

     
       

    Errored Seconds - Path

     
       

    Severely Errored Seconds - Path

     
       

    Unavailable Seconds - Path

     
       

    Protection Switch Count

     
    1. To enable real-time PMs, right-click on a pseudowire service in the tree view or in the background of a pseudowire service topology view, and select Enable Realtime PMs >Pseudowire

      Real-time PM collection for the pseudowire service is started, and a PM data widget title bar is displayed for each PM collection point. Additionally, a graphical view displaying the PMs pops up on the screen.

    2. Click the PM data widget title bar to show or hide the PM data.

      Figure 1: Real-time PMs

      Real-time PMs
    3. To change the domain (horizontal) scale of the graphs, highlight the desired area by left-clicking and dragging the mouse to highlight the area of focus, and release.

      Repeat until the desired magnification is achieved.

      Note: You can also change the scale by right-clicking on a graph, and selecting Zoom In>Domain Axis or Zoom Out>Domain Axis. This changes the horizontal scale while keeping the center of the range as the area of focus.

    4. To turn off real-time PMs, right-click the background in the pseudowire services topology window and choose Disable Realtime PMs.