    Historical PM Counters for Optical Interfaces on MX Series and PTX Series Routers

    PSM supports the retrieval and display of historical PMs from optical interfaces on MX Series and PTX Series routers. The actual PMs supported depend on the configuration and the software running on the router, and may include some or all of the following:

    Table 1: Optics PMs

    Name (abbreviated)

    Description

    Units

    CD-Avg, CD-Min, CD-Max

    Residual chromatic dispersion, average/minimum/maximum

    ps/nm

    CFO-Avg, CFO-Min, CFO-Max

    Carrier frequency offset, average/minimum/maximum

    MHz

    DGD-Avg, DGD-Min, DGD-Max

    Differential group delay, average/minimum/maximum

    ps

    Pwr-Rx-Avg, Pwr-Rx-Min, Pwr-Rx-Max

    Optical power receive, average/minimum/maximum

    0.01 dBm

    Pwr-Tx-Avg, Pwr-Tx-Min, Pwr-Tx-Max

    Optical power transmit, average/minimum/maximum

    0.01 dBm

    Q-Avg, Q-Min, Q-Max

    Q factor, average/minimum/maximum

    0.1 dB

    SNR-Avg, SNR-Min, SNR-Max

    Signal-to-noise ratio, average/minimum/maximum

    0.1 dB

    Temp-Avg, Temp-Min, Temp-Max

    Transceiver temperature, average/minimum/maximum

    °C

    Table 2: OTU PMs

    Name (abbreviated)

    Description

    Units

    FEC-BER-Avg-NearEnd, FEC-BER-Min-NearEnd, FEC-BER-Max-NearEnd

    FEC bit error rate, average/minimum/maximum

    none

    FEC-CorrectedErr-NearEnd

    FEC corrected errors

    none

    FEC-UncorrectedWords-NearEnd

    FEC uncorrected words

    none

    OTU-BBE-NearEnd, OTU-BBE-FarEnd

    OTU background block errors, near end, far end

    none

    OTU-ES-NearEnd, OTU-ES-FarEnd

    OTU errored seconds, near end, far end

    seconds

    OTU-SES-NearEnd, OTU-SES-FarEnd

    OTU severely errored seconds, near end, far end

    seconds

    OTU-UAS-NearEnd, OTU-UAS-FarEnd

    OTU unavailable seconds, near end, far end

    seconds

    Table 3: ODU PMs

    Name (abbreviated)

    Description

    Units

    ODU-BBE-NearEnd, ODU-BBE-FarEnd

    ODU background block errors, near end, far end

    none

    ODU-ES-NearEnd, ODU-ES-FarEnd

    ODU errored seconds, near end, far end

    seconds

    ODU-SES-NearEnd, ODU-SES-FarEnd

    ODU severely errored seconds, near end, far end

    seconds

    ODU-UAS-NearEnd, ODU-UAS-FarEnd

    ODU unavailable seconds, near end, far end

    seconds

    Note: PSM displays all counters reported by the router, which may include counters not listed above. Counters not listed above may not be supported. For the definitive list of the supported PM counters, consult the appropriate Juniper Networks documentation for the router.