Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

equipment

 

Syntax

Description

This command configures equipment on the system. If the specified equipment does not exist, the specified equipment is added.

Options

Parameter

Description

Range

Default Value

chassis_id

See equipment chassis.

passive_equip_id

The passive equipment identifier.

Note: When you add a FMD96, the DOL ports on the module are automatically added.

passive_equip_id:

  • muxdemux:0/slot for the D96MD

  • md:0/slot for the FMD96

  • dcmeqpt:0/slot for DCM equipment

See Slot Identifier Ranges for the slot range.

None

alias string

A user-defined name for the passive module

A character string.

An empty string

custom1, custom2, custom3 string

Customizable text field for operator's use

0 to 255 characters.

An empty string

location string

The physical location of the passive module

A character string.

An empty string

pec pec

The product equipment code for the passive module

Note: This parameter is mandatory.

pec:

  • D96MD: BT8A96MD01, BT8A96MD02

  • FMD96: BT8A78MD03

None

Required Privilege Level

Related Documentation

  • None

Sample Output

The following creates a 96-Channel DWDM Mux/Demux:

bti7800(config)# equipment muxdemux:0/5 pec BT8A96MD01