equipment chassis

 

Syntax

Description

This command sets parameters for the specified chassis. If the chassis does not yet exist, the chassis is created. The first chassis created is assigned an identifier of 1 automatically.

Options

Parameter

Description

Range

Default Value

chassis_id

The chassis identifier

chassis_id:

  • Main chassis (hub): chassis:1

  • Satellite chassis: chassis:2

None

The number 1 is always used for the first chassis installed.

admin-status status

Sets the administrative status of the chassis

status:

  • up

  • down

  • testing (not supported)

up

alias string

A user-defined name for the chassis

A character string.

An empty string

chassis-type type

The chassis type

type:

  • 1-Slot

  • 2-Slot

  • 6-Slot (not supported)

  • 14-Slot

None

custom1, custom2, custom3 string

Customizable text field for operator's use

0 to 255 characters

An empty string

location string

The physical location of the chassis

A character string

An empty string

module module_id

The module identifier

See equipment chassis module.

None

pec pec

The chassis product equipment code

A pre-defined product code. You can set this attribute directly or you can let the system set this attribute automatically when you configure the chassis-type.

  • BT8A78CH1

  • BT8A78CH2-I02

  • BT8A78CH14

Depends on the chassis-type

Required Privilege Level

Related Documentation

Sample Output

The following creates a BTI7814 chassis with a chassis identifier of 2.

bti7800(config)# equipment chassis:2 chassis-type 14-Slot