equipment chassis module roadm

 

Syntax

Description

This command sets parameters for the specified ROADM module. If the ROADM module does not yet exist, the ROADM module is created.

Options

Parameter

Description

Range

Default Value

chassis_id

The chassis identifier

chassis_id:

  • Main chassis (hub): chassis:1

  • Satellite chassis: chassis:2

None

module module_id

The ROADM module identifier

module_id

  • roadm:chassis/slot

None

admin-status status

The administrative status of the module

status:

  • up

  • down

  • testing (not supported)

up

custom1, custom2, custom3 string

Customizable text field for operator's use

0 to 255 characters

An empty string

pec pec

The ROADM product equipment code

A pre-defined product code. You can set this attribute directly or you can let the system set this attribute automatically when you configure the roadm-card-type.

None

preamplifier preamplifier_id

The preamplifier identifier

Specify only if you are adding a PRE module.

preamplifier_id:

  • pre:chassis/slot/1

None

roadm-card-type type

The ROADM type

type:

  • 2-port: ROADM2

  • 9-port (not supported)

  • 20-port (not supported)

None

Additional Information

The following are automatically created when you create a ROADM module:

  • DOL client, line, and PRE ports

  • DOL optical multiplex sections (OMS) for the client and line ports

  • DOL optical service channels (OSC) for the client and line ports

Required Privilege Level

Related Documentation

Sample Output

The following creates a ROADM2 module (output truncated for clarity):

bti7800(config)# equipment chassis:1 module roadm:1/6
bti7800(config-module-roadm:1/6)# do show dol