Provisioning Transponding and Muxponding Cross-Connects

 

Supported Cross-Connects

Cross-connects can be created between interfaces within the same UFM. Cross-connects cannot be created across UFMs. Depending on what you are cross-connecting, you can be regenerating, transponding, or muxponding.

Table 1 lists the cross-connects that are supported. The A and B designations in the table are used only to distinguish between the two cross-connect endpoints. They are assigned arbitrarily and are interchangeable.

Note

Not all interfaces are supported on all transceivers. To see which transceivers support which interfaces, see UFM Interfaces.

Note

The UFM6 is supported starting with release 4.1.

Note

When cross-connecting two 10-Gbps interfaces on a UFM3 equipped with 12x SFP+ BICs, both interfaces must reside on the same BIC.

Table 1: UFM Cross-Connects

Description

Supported UFMs

Interface A

Interface B

Rate

Introduced in Release

Regenerating

 

10GbE to/from 10GbE

UFM3 UFM4

10ge on an SFP+ transceiver

10ge on an SFP+ transceiver

10GbE

Before 2.1.1

SONET/SDH (OC-192/STM-64/ 10GbE WAN PHY) to/from SONET/SDH (OC-192/STM-64/ 10GbE WAN PHY)

UFM3 UFM4

oc192/stm64/wanoc192/wanstm64 on an SFP+ transceiver

oc192/stm64/wanoc192/wanstm64 on an SFP+ transceiver

OC-192 or STM-64

Before 2.1.1

OTU2 to/from OTU2

UFM3 UFM4

odu2 on an SFP+ transceiver

odu2 on an SFP+ transceiver

ODU2

Before 2.1.1

OTU2e to/from OTU2e

UFM3

odu2e on an SFP+ transceiver

odu2e on an SFP+ transceiver

ODU2e

4.1

100GbE to/from 100GbE

UFM3

100ge on a CFP transceiver

100ge on a CFP transceiver

100GbE

4.2

OTU4 to/from OTU4

UFM3 UFM4

odu4 on a CFP or on the integrated transceiver

odu4 on a CFP or on the integrated transceiver

ODU4

Before 2.1.1

UFM61

odu4 on a QSFP28 transceiver

odu4 on the integrated transceiver

ODU4

4.3

Transponding

 

10GbE to/from OTU2

UFM3 UFM4

10ge on an SFP+ transceiver

odu2 on an SFP+ transceiver

ODU2

Before 2.1.1

SONET/SDH (OC-192/STM-64/ 10GbE WAN PHY) to/from OTU2

UFM3 UFM4

oc192/stm64/wanoc192/wanstm64 on an SFP+ transceiver

odu2 on an SFP+ transceiver

ODU2

Before 2.1.1

100GbE to/from OTU4

UFM3 UFM4

100ge on a CFP transceiver

odu4 on a CFP or on the integrated transceiver

ODU4

Before 2.1.1

UFM61

100ge on a QSFP28 transceiver

odu4 on the integrated transceiver

ODU4

4.1

Muxponding

 

10GbE to/from OTU4

UFM3 UFM4

10ge on an SFP+ transceiver

odu2 within an odu4 on a CFP or on the integrated transceiver

ODU2

Before 2.1.1

UFM61

10ge on a QSFP+ transceiver

odu2e within an odu4 on the integrated transceiver

ODU2e

4.1

OTU2 to/from OTU4

UFM3 UFM4

odu2 on an SFP+ transceiver

odu2 within an odu4 on a CFP or on the integrated transceiver

ODU2

Before 2.1.1

UFM61

odu2 on a QSFP+ transceiver

odu2 within an odu4 on the integrated transceiver

ODU2

4.2

OTU2e to/from OTU4

UFM3

odu2e on an SFP+ transceiver

odu2e within an odu4 on a CFP or on the integrated transceiver

ODU2e

4.1

UFM61

odu2e on a QSFP+ transceiver

odu2e within an odu4 on the integrated transceiver

ODU2e

4.2

SONET/SDH (OC-192/STM-64) to/from OTU4

UFM3 UFM4

oc192/stm64 on an SFP+ transceiver

odu2 within an odu4 on a CFP or on the integrated transceiver

ODU2

Before 2.1.1

UFM61

oc192/stm64 on a QSFP+ transceiver

odu2 within an odu4 on the integrated transceiver

ODU2

4.2

SONET/SDH (10GbE WAN PHY) to/from OTU4

UFM3 UFM4

wanoc192/wanstm64 on an SFP+ transceiver

odu2 within an odu4 on a CFP or on the integrated transceiver

ODU2

Before 2.1.1

Fibre Channel to/from OTU4

UFM61

8gfc on a QSFP+ transceiver

odu2 within an odu4 on the integrated transceiver

ODU2

4.3

10gfc on a QSFP+ transceiver

odu2e within an odu4 on the integrated transceiver

ODU2e

4.3

40GbE to/from OTU4

UFM61

40ge on a QSFP+ 40GE transceiver

odu3 within an odu4 on the integrated transceiver

ODU3

4.4

1 UFM6 modules have fixed cross-connect mappings. See Table 2.

Table 2: UFM6 Fixed Cross-Connect Mappings

Description

Client Interface

Line Interface

Introduced in Release

100GbE to/from OTU4

100ge:chassis/slot/1/1

odu4:chassis/slot/2/1/1.1.1

4.1

100ge:chassis/slot/1/2

odu4:chassis/slot/2/1/1.1.2

4.1

100ge:chassis/slot/1/6

odu4:chassis/slot/2/1/2.1.1

4.1

100ge:chassis/slot/1/7

odu4:chassis/slot/2/1/2.1.2

4.1

OTU4 to/from OTU4

odu4:chassis/slot/1/1

odu4:chassis/slot/2/1/1.1.1

4.3

odu4:chassis/slot/1/2

odu4:chassis/slot/2/1/1.1.2

4.3

odu4:chassis/slot/1/6

odu4:chassis/slot/2/1/2.1.1

4.3

odu4:chassis/slot/1/7

odu4:chassis/slot/2/1/2.1.2

4.3

10GbE/SONET/SDH/OTU2 to/from subinterface within OTU4

10ge:chassis/slot/1/1/1

oc192:chassis/slot/1/1/1

stm64:chassis/slot/1/1/1

odu2:chassis/slot/1/1/1

odu2e:chassis/slot/1/1/1

8gfc:chassis/slot/1/1/1

10gfc:chassis/slot/1/1/1

odu2e:chassis/slot/2/1/1.1.1.1

odu2:chassis/slot/2/1/1.1.1.1

odu2:chassis/slot/2/1/1.1.1.1

odu2:chassis/slot/2/1/1.1.1.1

odu2e:chassis/slot/2/1/1.1.1.1

odu2:chassis/slot/2/1/1.1.1.1

odu2e:chassis/slot/2/1/1.1.1.1

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/1/2

oc192:chassis/slot/1/1/2

stm64:chassis/slot/1/1/2

odu2:chassis/slot/1/1/2

odu2e:chassis/slot/1/1/2

8gfc:chassis/slot/1/1/2

10gfc:chassis/slot/1/1/2

odu2e:chassis/slot/2/1/1.1.1.2

odu2:chassis/slot/2/1/1.1.1.2

odu2:chassis/slot/2/1/1.1.1.2

odu2:chassis/slot/2/1/1.1.1.2

odu2e:chassis/slot/2/1/1.1.1.2

odu2:chassis/slot/2/1/1.1.1.2

odu2e:chassis/slot/2/1/1.1.1.2

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/1/3

oc192:chassis/slot/1/1/3

stm64:chassis/slot/1/1/3

odu2:chassis/slot/1/1/3

odu2e:chassis/slot/1/1/3

8gfc:chassis/slot/1/1/3

10gfc:chassis/slot/1/1/3

odu2e:chassis/slot/2/1/1.1.1.3

odu2:chassis/slot/2/1/1.1.1.3

odu2:chassis/slot/2/1/1.1.1.3

odu2:chassis/slot/2/1/1.1.1.3

odu2e:chassis/slot/2/1/1.1.1.3

odu2:chassis/slot/2/1/1.1.1.3

odu2e:chassis/slot/2/1/1.1.1.3

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/1/4

oc192:chassis/slot/1/1/4

stm64:chassis/slot/1/1/4

odu2:chassis/slot/1/1/4

odu2e:chassis/slot/1/1/4

8gfc:chassis/slot/1/1/4

10gfc:chassis/slot/1/1/4

odu2e:chassis/slot/2/1/1.1.1.4

odu2:chassis/slot/2/1/1.1.1.4

odu2:chassis/slot/2/1/1.1.1.4

odu2:chassis/slot/2/1/1.1.1.4

odu2e:chassis/slot/2/1/1.1.1.4

odu2:chassis/slot/2/1/1.1.1.4

odu2e:chassis/slot/2/1/1.1.1.4

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/2/1

oc192:chassis/slot/1/2/1

stm64:chassis/slot/1/2/1

odu2:chassis/slot/1/2/1

odu2e:chassis/slot/1/2/1

8gfc:chassis/slot/1/2/1

10gfc:chassis/slot/1/2/1

odu2e:chassis/slot/2/1/1.1.1.5

odu2:chassis/slot/2/1/1.1.1.5

odu2:chassis/slot/2/1/1.1.1.5

odu2:chassis/slot/2/1/1.1.1.5

odu2e:chassis/slot/2/1/1.1.1.5

odu2:chassis/slot/2/1/1.1.1.5

odu2e:chassis/slot/2/1/1.1.1.5

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/2/2

oc192:chassis/slot/1/2/2

stm64:chassis/slot/1/2/2

odu2:chassis/slot/1/2/2

odu2e:chassis/slot/1/2/2

8gfc:chassis/slot/1/2/2

10gfc:chassis/slot/1/2/2

odu2e:chassis/slot/2/1/1.1.1.6

odu2:chassis/slot/2/1/1.1.1.6

odu2:chassis/slot/2/1/1.1.1.6

odu2:chassis/slot/2/1/1.1.1.6

odu2e:chassis/slot/2/1/1.1.1.6

odu2:chassis/slot/2/1/1.1.1.6

odu2e:chassis/slot/2/1/1.1.1.6

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/2/3

oc192:chassis/slot/1/2/3

stm64:chassis/slot/1/2/3

odu2:chassis/slot/1/2/3

odu2e:chassis/slot/1/2/3

8gfc:chassis/slot/1/2/3

10gfc:chassis/slot/1/2/3

odu2e:chassis/slot/2/1/1.1.1.7

odu2:chassis/slot/2/1/1.1.1.7

odu2:chassis/slot/2/1/1.1.1.7

odu2:chassis/slot/2/1/1.1.1.7

odu2e:chassis/slot/2/1/1.1.1.7

odu2:chassis/slot/2/1/1.1.1.7

odu2e:chassis/slot/2/1/1.1.1.7

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/2/4

oc192:chassis/slot/1/2/4

stm64:chassis/slot/1/2/4

odu2:chassis/slot/1/2/4

odu2e:chassis/slot/1/2/4

8gfc:chassis/slot/1/2/4

10gfc:chassis/slot/1/2/4

odu2e:chassis/slot/2/1/1.1.1.8

odu2:chassis/slot/2/1/1.1.1.8

odu2:chassis/slot/2/1/1.1.1.8

odu2:chassis/slot/2/1/1.1.1.8

odu2e:chassis/slot/2/1/1.1.1.8

odu2:chassis/slot/2/1/1.1.1.8

odu2e:chassis/slot/2/1/1.1.1.8

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/3/1

oc192:chassis/slot/1/3/1

stm64:chassis/slot/1/3/1

odu2:chassis/slot/1/3/1

odu2e:chassis/slot/1/3/1

8gfc:chassis/slot/1/3/1

10gfc:chassis/slot/1/3/1

odu2e:chassis/slot/2/1/1.1.1.9

odu2:chassis/slot/2/1/1.1.1.9

odu2:chassis/slot/2/1/1.1.1.9

odu2:chassis/slot/2/1/1.1.1.9

odu2e:chassis/slot/2/1/1.1.1.9

odu2:chassis/slot/2/1/1.1.1.9

odu2e:chassis/slot/2/1/1.1.1.9

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/3/2

oc192:chassis/slot/1/3/2

stm64:chassis/slot/1/3/2

odu2:chassis/slot/1/3/2

odu2e:chassis/slot/1/3/2

8gfc:chassis/slot/1/3/2

10gfc:chassis/slot/1/3/2

odu2e:chassis/slot/2/1/1.1.1.10

odu2:chassis/slot/2/1/1.1.1.10

odu2:chassis/slot/2/1/1.1.1.10

odu2:chassis/slot/2/1/1.1.1.10

odu2e:chassis/slot/2/1/1.1.1.10

odu2:chassis/slot/2/1/1.1.1.10

odu2e:chassis/slot/2/1/1.1.1.10

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/3/3

oc192:chassis/slot/1/3/3

stm64:chassis/slot/1/3/3

odu2:chassis/slot/1/3/3

odu2e:chassis/slot/1/3/3

8gfc:chassis/slot/1/3/3

10gfc:chassis/slot/1/3/3

odu2e:chassis/slot/2/1/1.1.2.1

odu2:chassis/slot/2/1/1.1.2.1

odu2:chassis/slot/2/1/1.1.2.1

odu2:chassis/slot/2/1/1.1.2.1

odu2e:chassis/slot/2/1/1.1.2.1

odu2:chassis/slot/2/1/1.1.2.1

odu2e:chassis/slot/2/1/1.1.2.1

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/3/4

oc192:chassis/slot/1/3/4

stm64:chassis/slot/1/3/4

odu2:chassis/slot/1/3/4

odu2e:chassis/slot/1/3/4

8gfc:chassis/slot/1/3/4

10gfc:chassis/slot/1/3/4

odu2e:chassis/slot/2/1/1.1.2.2

odu2:chassis/slot/2/1/1.1.2.2

odu2:chassis/slot/2/1/1.1.2.2

odu2:chassis/slot/2/1/1.1.2.2

odu2e:chassis/slot/2/1/1.1.2.2

odu2:chassis/slot/2/1/1.1.2.2

odu2e:chassis/slot/2/1/1.1.2.2

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/4/1

oc192:chassis/slot/1/4/1

stm64:chassis/slot/1/4/1

odu2:chassis/slot/1/4/1

odu2e:chassis/slot/1/4/1

8gfc:chassis/slot/1/4/1

10gfc:chassis/slot/1/4/1

odu2e:chassis/slot/2/1/1.1.2.3

odu2:chassis/slot/2/1/1.1.2.3

odu2:chassis/slot/2/1/1.1.2.3

odu2:chassis/slot/2/1/1.1.2.3

odu2e:chassis/slot/2/1/1.1.2.3

odu2:chassis/slot/2/1/1.1.2.3

odu2e:chassis/slot/2/1/1.1.2.3

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/4/2

oc192:chassis/slot/1/4/2

stm64:chassis/slot/1/4/2

odu2:chassis/slot/1/4/2

odu2e:chassis/slot/1/4/2

8gfc:chassis/slot/1/4/2

10gfc:chassis/slot/1/4/2

odu2e:chassis/slot/2/1/1.1.2.4

odu2:chassis/slot/2/1/1.1.2.4

odu2:chassis/slot/2/1/1.1.2.4

odu2:chassis/slot/2/1/1.1.2.4

odu2e:chassis/slot/2/1/1.1.2.4

odu2:chassis/slot/2/1/1.1.2.4

odu2e:chassis/slot/2/1/1.1.2.4

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/4/3

oc192:chassis/slot/1/4/3

stm64:chassis/slot/1/4/3

odu2:chassis/slot/1/4/3

odu2e:chassis/slot/1/4/3

8gfc:chassis/slot/1/4/3

10gfc:chassis/slot/1/4/3

odu2e:chassis/slot/2/1/1.1.2.5

odu2:chassis/slot/2/1/1.1.2.5

odu2:chassis/slot/2/1/1.1.2.5

odu2:chassis/slot/2/1/1.1.2.5

odu2e:chassis/slot/2/1/1.1.2.5

odu2:chassis/slot/2/1/1.1.2.5

odu2e:chassis/slot/2/1/1.1.2.5

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/4/4

oc192:chassis/slot/1/4/4

stm64:chassis/slot/1/4/4

odu2:chassis/slot/1/4/4

odu2e:chassis/slot/1/4/4

8gfc:chassis/slot/1/4/4

10gfc:chassis/slot/1/4/4

odu2e:chassis/slot/2/1/1.1.2.6

odu2:chassis/slot/2/1/1.1.2.6

odu2:chassis/slot/2/1/1.1.2.6

odu2:chassis/slot/2/1/1.1.2.6

odu2e:chassis/slot/2/1/1.1.2.6

odu2:chassis/slot/2/1/1.1.2.6

odu2e:chassis/slot/2/1/1.1.2.6

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/5/1

oc192:chassis/slot/1/5/1

stm64:chassis/slot/1/5/1

odu2:chassis/slot/1/5/1

odu2e:chassis/slot/1/5/1

8gfc:chassis/slot/1/5/1

10gfc:chassis/slot/1/5/1

odu2e:chassis/slot/2/1/1.1.2.7

odu2:chassis/slot/2/1/1.1.2.7

odu2:chassis/slot/2/1/1.1.2.7

odu2:chassis/slot/2/1/1.1.2.7

odu2e:chassis/slot/2/1/1.1.2.7

odu2:chassis/slot/2/1/1.1.2.7

odu2e:chassis/slot/2/1/1.1.2.7

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/5/2

oc192:chassis/slot/1/5/2

stm64:chassis/slot/1/5/2

odu2:chassis/slot/1/5/2

odu2e:chassis/slot/1/5/2

8gfc:chassis/slot/1/5/2

10gfc:chassis/slot/1/5/2

odu2e:chassis/slot/2/1/1.1.2.8

odu2:chassis/slot/2/1/1.1.2.8

odu2:chassis/slot/2/1/1.1.2.8

odu2:chassis/slot/2/1/1.1.2.8

odu2e:chassis/slot/2/1/1.1.2.8

odu2:chassis/slot/2/1/1.1.2.8

odu2e:chassis/slot/2/1/1.1.2.8

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/5/3

oc192:chassis/slot/1/5/3

stm64:chassis/slot/1/5/3

odu2:chassis/slot/1/5/3

odu2e:chassis/slot/1/5/3

8gfc:chassis/slot/1/5/3

10gfc:chassis/slot/1/5/3

odu2e:chassis/slot/2/1/1.1.2.9

odu2:chassis/slot/2/1/1.1.2.9

odu2:chassis/slot/2/1/1.1.2.9

odu2:chassis/slot/2/1/1.1.2.9

odu2e:chassis/slot/2/1/1.1.2.9

odu2:chassis/slot/2/1/1.1.2.9

odu2e:chassis/slot/2/1/1.1.2.9

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/5/4

oc192:chassis/slot/1/5/4

stm64:chassis/slot/1/5/4

odu2:chassis/slot/1/5/4

odu2e:chassis/slot/1/5/4

8gfc:chassis/slot/1/5/4

10gfc:chassis/slot/1/5/4

odu2e:chassis/slot/2/1/1.1.2.10

odu2:chassis/slot/2/1/1.1.2.10

odu2:chassis/slot/2/1/1.1.2.10

odu2:chassis/slot/2/1/1.1.2.10

odu2e:chassis/slot/2/1/1.1.2.10

odu2:chassis/slot/2/1/1.1.2.10

odu2e:chassis/slot/2/1/1.1.2.10

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/6/1

oc192:chassis/slot/1/6/1

stm64:chassis/slot/1/6/1

odu2:chassis/slot/1/6/1

odu2e:chassis/slot/1/6/1

8gfc:chassis/slot/1/6/1

10gfc:chassis/slot/1/6/1

odu2e:chassis/slot/2/1/2.1.1.1

odu2:chassis/slot/2/1/2.1.1.1

odu2:chassis/slot/2/1/2.1.1.1

odu2:chassis/slot/2/1/2.1.1.1

odu2e:chassis/slot/2/1/2.1.1.1

odu2:chassis/slot/2/1/2.1.1.1

odu2e:chassis/slot/2/1/2.1.1.1

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/6/2

oc192:chassis/slot/1/6/2

stm64:chassis/slot/1/6/2

odu2:chassis/slot/1/6/2

odu2e:chassis/slot/1/6/2

8gfc:chassis/slot/1/6/2

10gfc:chassis/slot/1/6/2

odu2e:chassis/slot/2/1/2.1.1.2

odu2:chassis/slot/2/1/2.1.1.2

odu2:chassis/slot/2/1/2.1.1.2

odu2:chassis/slot/2/1/2.1.1.2

odu2e:chassis/slot/2/1/2.1.1.2

odu2:chassis/slot/2/1/2.1.1.2

odu2e:chassis/slot/2/1/2.1.1.2

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/6/3

oc192:chassis/slot/1/6/3

stm64:chassis/slot/1/6/3

odu2:chassis/slot/1/6/3

odu2e:chassis/slot/1/6/3

8gfc:chassis/slot/1/6/3

10gfc:chassis/slot/1/6/3

odu2e:chassis/slot/2/1/2.1.1.3

odu2:chassis/slot/2/1/2.1.1.3

odu2:chassis/slot/2/1/2.1.1.3

odu2:chassis/slot/2/1/2.1.1.3

odu2e:chassis/slot/2/1/2.1.1.3

odu2:chassis/slot/2/1/2.1.1.3

odu2e:chassis/slot/2/1/2.1.1.3

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/6/4

oc192:chassis/slot/1/6/4

stm64:chassis/slot/1/6/4

odu2:chassis/slot/1/6/4

odu2e:chassis/slot/1/6/4

8gfc:chassis/slot/1/6/4

10gfc:chassis/slot/1/6/4

odu2e:chassis/slot/2/1/2.1.1.4

odu2:chassis/slot/2/1/2.1.1.4

odu2:chassis/slot/2/1/2.1.1.4

odu2:chassis/slot/2/1/2.1.1.4

odu2e:chassis/slot/2/1/2.1.1.4

odu2:chassis/slot/2/1/2.1.1.4

odu2e:chassis/slot/2/1/2.1.1.4

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/7/1

oc192:chassis/slot/1/7/1

stm64:chassis/slot/1/7/1

odu2:chassis/slot/1/7/1

odu2e:chassis/slot/1/7/1

8gfc:chassis/slot/1/7/1

10gfc:chassis/slot/1/7/1

odu2e:chassis/slot/2/1/2.1.1.5

odu2:chassis/slot/2/1/2.1.1.5

odu2:chassis/slot/2/1/2.1.1.5

odu2:chassis/slot/2/1/2.1.1.5

odu2e:chassis/slot/2/1/2.1.1.5

odu2:chassis/slot/2/1/2.1.1.5

odu2e:chassis/slot/2/1/2.1.1.5

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/7/2

oc192:chassis/slot/1/7/2

stm64:chassis/slot/1/7/2

odu2:chassis/slot/1/7/2

odu2e:chassis/slot/1/7/2

8gfc:chassis/slot/1/7/2

10gfc:chassis/slot/1/7/2

odu2e:chassis/slot/2/1/2.1.1.6

odu2:chassis/slot/2/1/2.1.1.6

odu2:chassis/slot/2/1/2.1.1.6

odu2:chassis/slot/2/1/2.1.1.6

odu2e:chassis/slot/2/1/2.1.1.6

odu2:chassis/slot/2/1/2.1.1.6

odu2e:chassis/slot/2/1/2.1.1.6

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/7/3

oc192:chassis/slot/1/7/3

stm64:chassis/slot/1/7/3

odu2:chassis/slot/1/7/3

odu2e:chassis/slot/1/7/3

8gfc:chassis/slot/1/7/3

10gfc:chassis/slot/1/7/3

odu2e:chassis/slot/2/1/2.1.1.7

odu2:chassis/slot/2/1/2.1.1.7

odu2:chassis/slot/2/1/2.1.1.7

odu2:chassis/slot/2/1/2.1.1.7

odu2e:chassis/slot/2/1/2.1.1.7

odu2:chassis/slot/2/1/2.1.1.7

odu2e:chassis/slot/2/1/2.1.1.7

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/7/4

oc192:chassis/slot/1/7/4

stm64:chassis/slot/1/7/4

odu2:chassis/slot/1/7/4

odu2e:chassis/slot/1/7/4

8gfc:chassis/slot/1/7/4

10gfc:chassis/slot/1/7/4

odu2e:chassis/slot/2/1/2.1.1.8

odu2:chassis/slot/2/1/2.1.1.8

odu2:chassis/slot/2/1/2.1.1.8

odu2:chassis/slot/2/1/2.1.1.8

odu2e:chassis/slot/2/1/2.1.1.8

odu2:chassis/slot/2/1/2.1.1.8

odu2e:chassis/slot/2/1/2.1.1.8

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/8/1

oc192:chassis/slot/1/8/1

stm64:chassis/slot/1/8/1

odu2:chassis/slot/1/8/1

odu2e:chassis/slot/1/8/1

8gfc:chassis/slot/1/8/1

10gfc:chassis/slot/1/8/1

odu2e:chassis/slot/2/1/2.1.1.9

odu2:chassis/slot/2/1/2.1.1.9

odu2:chassis/slot/2/1/2.1.1.9

odu2:chassis/slot/2/1/2.1.1.9

odu2e:chassis/slot/2/1/2.1.1.9

odu2:chassis/slot/2/1/2.1.1.9

odu2e:chassis/slot/2/1/2.1.1.9

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/8/2

oc192:chassis/slot/1/8/2

stm64:chassis/slot/1/8/2

odu2:chassis/slot/1/8/2

odu2e:chassis/slot/1/8/2

8gfc:chassis/slot/1/8/2

10gfc:chassis/slot/1/8/2

odu2e:chassis/slot/2/1/2.1.1.10

odu2:chassis/slot/2/1/2.1.1.10

odu2:chassis/slot/2/1/2.1.1.10

odu2:chassis/slot/2/1/2.1.1.10

odu2e:chassis/slot/2/1/2.1.1.10

odu2:chassis/slot/2/1/2.1.1.10

odu2e:chassis/slot/2/1/2.1.1.10

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/8/3

oc192:chassis/slot/1/8/3

stm64:chassis/slot/1/8/3

odu2:chassis/slot/1/8/3

odu2e:chassis/slot/1/8/3

8gfc:chassis/slot/1/8/3

10gfc:chassis/slot/1/8/3

odu2e:chassis/slot/2/1/2.1.2.1

odu2:chassis/slot/2/1/2.1.2.1

odu2:chassis/slot/2/1/2.1.2.1

odu2:chassis/slot/2/1/2.1.2.1

odu2e:chassis/slot/2/1/2.1.2.1

odu2:chassis/slot/2/1/2.1.2.1

odu2e:chassis/slot/2/1/2.1.2.1

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/8/4

oc192:chassis/slot/1/8/4

stm64:chassis/slot/1/8/4

odu2:chassis/slot/1/8/4

odu2e:chassis/slot/1/8/4

8gfc:chassis/slot/1/8/4

10gfc:chassis/slot/1/8/4

odu2e:chassis/slot/2/1/2.1.2.2

odu2:chassis/slot/2/1/2.1.2.2

odu2:chassis/slot/2/1/2.1.2.2

odu2:chassis/slot/2/1/2.1.2.2

odu2e:chassis/slot/2/1/2.1.2.2

odu2:chassis/slot/2/1/2.1.2.2

odu2e:chassis/slot/2/1/2.1.2.2

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/9/1

oc192:chassis/slot/1/9/1

stm64:chassis/slot/1/9/1

odu2:chassis/slot/1/9/1

odu2e:chassis/slot/1/9/1

8gfc:chassis/slot/1/9/1

10gfc:chassis/slot/1/9/1

odu2e:chassis/slot/2/1/2.1.2.3

odu2:chassis/slot/2/1/2.1.2.3

odu2:chassis/slot/2/1/2.1.2.3

odu2:chassis/slot/2/1/2.1.2.3

odu2e:chassis/slot/2/1/2.1.2.3

odu2:chassis/slot/2/1/2.1.2.3

odu2e:chassis/slot/2/1/2.1.2.3

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/9/2

oc192:chassis/slot/1/9/2

stm64:chassis/slot/1/9/2

odu2:chassis/slot/1/9/2

odu2e:chassis/slot/1/9/2

8gfc:chassis/slot/1/9/2

10gfc:chassis/slot/1/9/2

odu2e:chassis/slot/2/1/2.1.2.4

odu2:chassis/slot/2/1/2.1.2.4

odu2:chassis/slot/2/1/2.1.2.4

odu2:chassis/slot/2/1/2.1.2.4

odu2e:chassis/slot/2/1/2.1.2.4

odu2:chassis/slot/2/1/2.1.2.4

odu2e:chassis/slot/2/1/2.1.2.4

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/9/3

oc192:chassis/slot/1/9/3

stm64:chassis/slot/1/9/3

odu2:chassis/slot/1/9/3

odu2e:chassis/slot/1/9/3

8gfc:chassis/slot/1/9/3

10gfc:chassis/slot/1/9/3

odu2e:chassis/slot/2/1/2.1.2.5

odu2:chassis/slot/2/1/2.1.2.5

odu2:chassis/slot/2/1/2.1.2.5

odu2:chassis/slot/2/1/2.1.2.5

odu2e:chassis/slot/2/1/2.1.2.5

odu2:chassis/slot/2/1/2.1.2.5

odu2e:chassis/slot/2/1/2.1.2.5

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/9/4

oc192:chassis/slot/1/9/4

stm64:chassis/slot/1/9/4

odu2:chassis/slot/1/9/4

odu2e:chassis/slot/1/9/4

8gfc:chassis/slot/1/9/4

10gfc:chassis/slot/1/9/4

odu2e:chassis/slot/2/1/2.1.2.6

odu2:chassis/slot/2/1/2.1.2.6

odu2:chassis/slot/2/1/2.1.2.6

odu2:chassis/slot/2/1/2.1.2.6

odu2e:chassis/slot/2/1/2.1.2.6

odu2:chassis/slot/2/1/2.1.2.6

odu2e:chassis/slot/2/1/2.1.2.6

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/10/1

oc192:chassis/slot/1/10/1

stm64:chassis/slot/1/10/1

odu2:chassis/slot/1/10/1

odu2e:chassis/slot/1/10/1

8gfc:chassis/slot/1/10/1

10gfc:chassis/slot/1/10/1

odu2e:chassis/slot/2/1/2.1.2.7

odu2:chassis/slot/2/1/2.1.2.7

odu2:chassis/slot/2/1/2.1.2.7

odu2:chassis/slot/2/1/2.1.2.7

odu2e:chassis/slot/2/1/2.1.2.7

odu2:chassis/slot/2/1/2.1.2.7

odu2e:chassis/slot/2/1/2.1.2.7

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/10/2

oc192:chassis/slot/1/10/2

stm64:chassis/slot/1/10/2

odu2:chassis/slot/1/10/2

odu2e:chassis/slot/1/10/2

8gfc:chassis/slot/1/10/2

10gfc:chassis/slot/1/10/2

odu2e:chassis/slot/2/1/2.1.2.8

odu2:chassis/slot/2/1/2.1.2.8

odu2:chassis/slot/2/1/2.1.2.8

odu2:chassis/slot/2/1/2.1.2.8

odu2e:chassis/slot/2/1/2.1.2.8

odu2:chassis/slot/2/1/2.1.2.8

odu2e:chassis/slot/2/1/2.1.2.8

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/10/3

oc192:chassis/slot/1/10/3

stm64:chassis/slot/1/10/3

odu2:chassis/slot/1/10/3

odu2e:chassis/slot/1/10/3

8gfc:chassis/slot/1/10/3

10gfc:chassis/slot/1/10/3

odu2e:chassis/slot/2/1/2.1.2.9

odu2:chassis/slot/2/1/2.1.2.9

odu2:chassis/slot/2/1/2.1.2.9

odu2:chassis/slot/2/1/2.1.2.9

odu2e:chassis/slot/2/1/2.1.2.9

odu2:chassis/slot/2/1/2.1.2.9

odu2e:chassis/slot/2/1/2.1.2.9

4.1

4.2

4.2

4.2

4.2

4.3

4.3

10ge:chassis/slot/1/10/4

oc192:chassis/slot/1/10/4

stm64:chassis/slot/1/10/4

odu2:chassis/slot/1/10/4

odu2e:chassis/slot/1/10/4

8gfc:chassis/slot/1/10/4

10gfc:chassis/slot/1/10/4

odu2e:chassis/slot/2/1/2.1.2.10

odu2:chassis/slot/2/1/2.1.2.10

odu2:chassis/slot/2/1/2.1.2.10

odu2:chassis/slot/2/1/2.1.2.10

odu2e:chassis/slot/2/1/2.1.2.10

odu2:chassis/slot/2/1/2.1.2.10

odu2e:chassis/slot/2/1/2.1.2.10

4.1

4.2

4.2

4.2

4.2

4.3

4.3

40GbE to/from subinterface within OTU4

40ge:chassis/slot/1/1

odu3:chassis/slot/2/1/1.1.1.1

4.4

40ge:chassis/slot/1/2

odu3:chassis/slot/2/1/1.1.1.2

4.4

40ge:chassis/slot/1/4

odu3:chassis/slot/2/1/1.1.2.1

4.4

40ge:chassis/slot/1/5

odu3:chassis/slot/2/1/1.1.2.2

4.4

40ge:chassis/slot/1/6

odu3:chassis/slot/2/1/2.1.1.1

4.4

40ge:chassis/slot/1/7

odu3:chassis/slot/2/1/2.1.1.2

4.4

40ge:chassis/slot/1/9

odu3:chassis/slot/2/1/2.1.2.1

4.4

40ge:chassis/slot/1/10

odu3:chassis/slot/2/1/2.1.2.2

4.4

Provisioning a Transponding Cross-Connect on a UFM3 or UFM4

Use this procedure to provision a cross-connect that transponds between interfaces on a UFM3 or UFM4. This procedure transponds a 100-Gigabit Ethernet signal into an ODU4 as an example, but the same procedure can be used for other protocols. See Supported cross-connects for more information on what interfaces can be cross-connected.

  1. Enter configuration mode.
    bti7800# config
  2. Create the interfaces to be cross-connected. The following example shows the creation of a 100-Gigabit Ethernet interface and an ODU4 interface.

    See Provisioning a Transport Interface for information on creating transport interfaces.

    1. Create the OTU4 interface. For example:

      When you create an OTU4 interface on a UFM3 or UFM4, the system automatically creates the corresponding ODU4 interface and configures it for no multiplexing.

      If you are cross-connecting an existing ODU4 interface that has been configured for multiplexing, you will need to change it to no multiplexing. For example:

    2. Create the 100-Gigabit Ethernet interface. For example:

    The following lists the interfaces created on the UFM in slot 7 (for example):

    bti7800(config)# do show interface | include 1/7
  3. Configure the cross-connect.

    The following example cross-connects the 100-Gigabit Ethernet interface with the ODU4 interface:

    bti7800(config)# cross-connect 100ge:1/7/2/1 odu4:1/7/1/1
  4. Optionally, specify the service name.

    For example:

    bti7800(config-cross-connect-100ge:1/7/2/1/odu4:1/7/1/1)# service-name circuit_17
  5. Apply the changes.
    bti7800(config-cross-connect-100ge:1/7/2/1/odu4:1/7/1/1)# commit
  6. Optionally, show the resulting cross-connect.

    For example:

    bti7800(config-cross-connect-100ge:1/7/2/1/odu4:1/7/1/1)# do show cross-connect table | include circuit_17

Provisioning a Transponding Cross-Connect on a UFM6

Use this procedure to provision a cross-connect that transponds between a 100-Gbps client interface and an OTU4 line interface on a UFM6. This procedure transponds a 100-Gigabit Ethernet signal into an ODU4 as an example. See Supported cross-connects for more information on what interfaces can be cross-connected.

  1. Enter configuration mode.
    bti7800# config
  2. Create the interfaces to be cross-connected. See Provisioning a Transport Interface for information on creating transport interfaces.Note

    The cross-connect mapping between the client and line interfaces on a UFM6 is fixed and cannot be changed. Ensure that the interfaces you create conform to the required mapping. See Supported cross-connects for more information.

    1. Create the optical channel interface. For example:

      The optical channel represents the optical signal and contains attributes that are shared by all contained OTU4 signals. The optical channel interface must exist before you can create an OTU4 interface. For more information on creating an optical channel interface, see Provisioning an Optical Channel Interface.

    2. Create the OTU4 interface and configure it as a non-multiplexed interface. When you create an OTU4 line interface on a UFM6, the system automatically creates the corresponding ODU4 interface and configures it for multiplexing. You will need to manually configure the ODU4 for non-multiplexing. For example:

    3. Create the 100-Gbps client interface. For example:

    The following lists the interfaces created on the UFM6 in slot 5 (for example):

    bti7800(config)# do show interface | include 1/5
  3. Configure the cross-connect.

    The following cross-connects the ODU4 line interface with the 100-Gbps client interface:

    bti7800(config)# cross-connect odu4:1/5/2/1/1.1.1 100ge:1/5/1/1
  4. Optionally, specify the service name.

    For example:

    bti7800(config-cross-connect-odu4:1/5/2/1/1.1.1 100ge:1/5/1/1)# service-name circuit_2129
  5. Apply the changes.
    bti7800(config-cross-connect-odu4:1/5/2/1/1.1.1 100ge:1/5/1/1)# commit
  6. Optionally, show the resulting cross-connect.

    For example:

    bti7800(config-cross-connect-odu4:1/5/2/1/1.1.1 100ge:1/5/1/1)# do show cross-connect table

Provisioning a Muxponding Cross-Connect on a UFM3 or UFM4

Use this procedure to provision a cross-connect that muxponds between a 10-Gbps interface and a 10-Gbps subinterface within a higher-order ODU4 on a UFM3 or UFM4. This procedure muxponds a 10-Gigabit Ethernet signal into an ODU2 as an example, but the same procedure can be used for other 10-Gbps protocols by cross-connecting other interfaces. See Supported cross-connects for information on the cross-connects these modules support.

  1. Enter configuration mode.
    bti7800# config
  2. Create the interfaces to be cross-connected. See Provisioning a Transport Interface for information on creating transport interfaces.
    1. Create the OTU4 interface and configure the automatically created ODU4 interface for multiplexing. For example:

      When you configure the ODU4 interface for multiplexing, the system automatically creates 10 ODU2 subinterfaces; for example, odu2:1/7/1/1.1 to odu2:1/7/1/1.10.

    2. Create the 10-Gbps client interface. For example:

    The following lists the interfaces created on the UFM in slot 7 (for example):

    bti7800(config)# do show interface | include 1/7
  3. If you are multiplexing into an ODU2e instead of an ODU2, delete the corresponding ODU2 subinterface and manually create the ODU2e subinterface. See Provisioning a Transport Interface for more information.

    For example:

  4. Configure the cross-connect.

    The following example cross-connects the 10-Gbps client interface with one of the subinterfaces on the ODU4:

    bti7800(config)# cross-connect 10ge:1/7/2/1 odu2:1/7/1/1.4
  5. Optionally, specify the service name.

    For example:

    bti7800(config-cross-connect-10ge:1/7/2/1/odu2:1/7/1/1.4)# service-name circuit_1714
  6. Apply the changes.
    bti7800(config-cross-connect-10ge:1/7/2/1/odu2:1/7/1/1.4)# commit
  7. Optionally, show the resulting cross-connect.

    For example:

    bti7800(config-cross-connect-10ge:1/7/2/1/odu2:1/7/1/1.4)# do show cross-connect table | include circuit_1714

Provisioning a Muxponding Cross-Connect on a UFM6

Use this procedure to provision a cross-connect that muxponds between a client interface and an ODU subinterface within a higher-order ODU4 on a UFM6. This procedure muxponds a 10-Gigabit Ethernet signal into an ODU2e within an ODU4 as an example, but the same procedure can be used for other 10-Gbps and 40-Gbps protocols by cross-connecting other interfaces. See Supported cross-connects for information on the cross-connects this module supports.

  1. Enter configuration mode.
    bti7800# config
  2. Create the interfaces to be cross-connected. See Provisioning a Transport Interface for information on creating transport interfaces.Note

    The cross-connect mapping between the client interface and the line subinterface on the ODU4 is fixed and cannot be changed. Ensure that the interfaces you create conform to the required mapping. See Supported cross-connects for more information.

    1. Create the optical channel interface. For example:

      The optical channel represents the optical signal and contains attributes that are shared by all contained OTU4 signals. The optical channel interface must exist before you can create an OTU4 interface. For more information on creating an optical channel interface, see Provisioning an Optical Channel Interface.

    2. Create the OTU4 line interface. For example:

      When you create an OTU4 line interface on a UFM6, the system automatically creates the corresponding ODU4 interface and configures it for multiplexing. The multiplexed ODU4 interface contains 10 automatically created ODU2e subinterfaces; for example, odu2e:1/5/2/1/1.1.1.1 to odu2e:1/5/2/1/1.1.1.10.

      If you are cross-connecting an existing ODU4 interface that has not been configured for multiplexing, you will need to configure it for multiplexing. For example:

    3. Create the client interface. For example, this creates a 10ge client interface for multiplexing into an ODU2 or ODU2e subinterface:

    The following lists the interfaces created on the UFM in slot 5 (for example):

    bti7800(config)# do show interface | include 1/5
  3. If you are multiplexing a 10-Gbps interface into an ODU2 or a 40-Gbps interface into an ODU3, delete the corresponding ODU2e subinterface and manually create the ODU2 or ODU3 subinterface. If you are creating an ODU3 subinterface, you will need to delete all ODU2e subinterfaces that use the same tributary slots as the ODU3. See Provisioning a Transport Interface for more information.

    For example, this deletes an ODU2e subinterface and creates an ODU2 subinterface:

  4. Configure the cross-connect.

    The following cross-connects the 10-Gbps interface with the associated ODU2e subinterface on the ODU4:

    bti7800(config)# cross-connect 10ge:1/5/1/1/1 odu2e:1/5/2/1/1.1.1.1
  5. Optionally, specify the service name.

    For example:

    bti7800(config-cross-connect-10ge:1/5/1/1/1 odu2e:1/5/2/1/1.1.1.1)# service-name circuit_2129
  6. Apply the changes.
    bti7800(config-cross-connect-10ge:1/5/1/1/1 odu2e:1/5/2/1/1.1.1.1)# commit
  7. Optionally, show the resulting cross-connect.

    For example:

    bti7800(config-cross-connect-10ge:1/5/1/1/1 odu2e:1/5/2/1/1.1.1.1)# do show cross-connect table