    show equipment module

    Syntax

    show equipment [ chassis_id ] module [ module_id [ bic [ bic_id [ transceiver [ transceiver_id ] ] ] ] [ operational-status [ status ] ] ]
    show equipment [ chassis_id ] module [ module_id [ transceiver [ transceiver_id ] ] [ operational-status [ status ] ] ]

    Description

    This command displays provisioned modules and provisioned equipment that the modules contain (at varying levels of specificity).

    Options

    Parameter

    Description

    Range

    Default

    chassis_id

    Restricts displayed equipment to the specified chassis.

    Note: The information displayed for the same equipment differs slightly depending on whether the chassis is or is not specified. See examples below.

    A valid chassis identifier (for example, chassis:1)

    If no chassis is specified, the displayed equipment can be from any chassis.

    module [module_id]

    Restricts displayed equipment to the specified module.

    A valid module identifier (for example, ufm:1/3)

    If no module is specified, the displayed equipment can be from any module.

    bic [bic_id]

    Restricts displayed equipment to the specified BIC.

    This option is only available if the containing module is a UFM.

    A valid BIC identifier (for example, bic:1/3/1) for the specified module

    If no BIC is specified, the displayed equipment can be from any BIC.

    transceiver [transceiver_id]

    Restricts displayed equipment to the specified transceiver.

    This option is only available if the containing module is a UFM.

    A valid transceiver identifier (for example, cfp:1/3/2/1) for the specified BIC or UFM

    If no transceiver is specified, the displayed equipment can be from any transceiver.

    operational-status [status]

    Restricts displayed equipment to the specified operational status.

    The following are the valid status values:

    • dormant
    • down
    • lowerLayerDown
    • notPresent
    • testing
    • unknown
    • up

    If no status is specified, the displayed equipment can contain any operational status.

    Additional Information

    The operational state or status can take on the following values:

    • up - The specified equipment is present, administratively enabled, and functioning normally.
    • down - The specified equipment is either administratively disabled, mismatched, or alarmed with a fault that makes it unable to provide its provisioned function.
    • notPresent - The equipment is not present in the location for which it is provisioned.
    • lowerLayerDown - Supporting equipment is reporting an operational state of down.
    • unknown - The operational state of the specified equipment cannot be determined, possibly because it is rebooting.

    Required Privilege Level

     

    Related Documentation

     

    Sample Output

    To display all modules:

    bti7800# show equipment module
    Module      PEC             Admin State  Oper State  Custom1  Custom2  Custom3 
    ----------  --------------  -----------  ----------  -------  -------  ------- 
    amp:1/4     BT8A78AMP1      enabled      down 
    cmm:1/A     BT8A78CMM1      enabled      up 
    cmm:1/B     BT8A78CMM1      enabled      up 
    fan:1/1     BT8A78FAN1      enabled      up 
    fan:1/2     BT8A78FAN1      enabled      up 
    fan:1/3     BT8A78FAN1      enabled      up 
    fan:1/4     BT8A78FAN1      enabled      up 
    fan:1/5     BT8A78FAN5      enabled      up 
    fan:1/6     BT8A78FAN5      enabled      up 
    ila:1/5     BT8A78AMPL      enabled      down 
    pem:1/1     BT8A78PEM3-DC   enabled      up 
    pem:1/2     BT8A78PEM3-DC   enabled      up 
    roadm:1/8   BT8A78RDM2      enabled      down 
    roadm:1/9   BT8A78RDM2      enabled      down 
    ufm:1/1     BT8A78UFM3      enabled      down 
    ufm:1/3     BT8A78UFM3      enabled      up 
    ufm:1/10    BT8A78UFM3      enabled      down 
    ufm:1/13    BT8A78UFM4      enabled      down 
    wps:1/12    BT8A78WPS4      enabled      down 

    To display all transceivers on a specific BIC:

    bti7800# show equipment chassis:1 module ufm:1/3 bic bic:1/3/1 transceiver
    Transceiver        PEC            Optical-Format  Admin    Oper  Custom1  Custom2  Custom3 
    ------------------ -------------- --------------- -------- ----  -------  -------  ------- 
    sfpPlus:1/3/1/1                   fixedX1         up       up                 
    sfpPlus:1/3/1/2                   fixedX1         up       up                   
    sfpPlus:1/3/1/3                   fixedX1         up       up                     
    sfpPlus:1/3/1/4                   fixedX1         up       up                 
    sfpPlus:1/3/1/5                   fixedX1         up       up                   
    sfpPlus:1/3/1/6                   fixedX1         up       up                  
    sfpPlus:1/3/1/7                   tunableX1       up       up                 
    sfpPlus:1/3/1/8                   tunableX1       up       up                   
    sfpPlus:1/3/1/9                   tunableX1       up       up                
    sfpPlus:1/3/1/10                  tunableX1       up       up                      
    sfpPlus:1/3/1/11                  tunableX1       up       up                  
    sfpPlus:1/3/1/12                  tunableX1       up       up                

    Modified: 2017-10-24