    CfgUnsupp

    Table 1: Condition Details

    Parameter

    Description

    Code

    cfgUnsupp

    Description/Cause

    Configuration unsupported: The indicated transceiver does not support the protocol configured on the associated interface.

    Entities Affected

    Transceivers

    Default Severity

    Not alarmed.

    Service Affecting

    Yes (true).

    Condition Clearing

    See Clearing a cfgUnsupp Condition.

    Related Fault Hierarchy

    Clearing a cfgUnsupp Condition

    Note: Follow all applicable safety requirements as described in the BTI7800 Series Hardware Overview and Installation Guide.

    1. If you installed the transceiver in error, uninstall the incorrect transceiver and install the correct transceiver.
    2. If you configured the interface with the incorrect protocol, delete the interface and create a new interface with the correct protocol.