    equipment chassis module ufm

    Syntax

    [no] equipment chassis_id module module_id [ admin-status status | bic bic_id | custom1 string | custom2 string | custom3 string | pec pec | transceiver transceiver_id | ufm-type type ]

    Description

    This command sets parameters for the specified UFM. If the UFM does not yet exist, the UFM is created.

    Options

    Parameter

    Description

    Range

    Default Value

    chassis_id

    The chassis identifier

    chassis_id:

    • Main chassis (hub): chassis:1
    • Satellite chassis: chassis:2

    None

    module module_id

    The UFM module identifier

    module_id:

    • ufm:chassis/slot

    None

    admin-status status

    Sets the administrative status of the module

    status:

    • up
    • down
    • testing (not supported)

    up

    bic bic_id

    The BIC identifier. See equipment chassis module ufm bic.

    custom1, custom2, custom3 string

    Customizable text field for operator's use

    0 to 255 characters

    An empty string

    pec pec

    The UFM product equipment code

    A pre-defined product code. You can set this attribute directly or you can let the system set this attribute automatically when you configure the ufm-type.

    None

    transceiver transceiver_id

    The transceiver identifier. This is only applicable for the UFMs with the integrated transceivers (UFM4, UFM6).

    See equipment chassis module ufm transceiver.

    ufm-type type

    The UFM type

    type:

    • msa-switching: deprecated
    • dual-bic-switching: deprecated
    • dual-bic-non-switching: UFM3, contains two BIC slots and does not provide fabric access
    • msa-non-switching: UFM4, contains one 100G Coherent MSA XCVR and one BIC slot, and does not provide fabric access
    • msa400-10g-100g-client: UFM6, contains one 400G Coherent MSA XCVR on the line side and transceiver ports on the client side

    None

    Required Privilege Level

     

    Related Documentation

     

    Sample Output

    The following creates a UFM3:

    bti7800(config)# equipment chassis:2 module ufm:1/1
    Value for 'ufm-type' [dual-bic-non-switching,dual-bic-switching,msa-non-switching,msa-switching]: dual-bic-non-switching 
    bti7800(config-module-ufm:1/1)# commit 
    Commit complete. 