    amp eqpt

    Syntax

    [no] amp eqpt name:location_id [ degreenum number | groupnum number ]

    Description

    This command configures the optical layer equipment and associated group and degree assignments.

    Options

    Parameter

    Description

    Range

    Default Value

    eqpt name:location_id

    This is the96-Channel Amplifier module or the DCM (Dispersion Compensation Module) or the multiplexer/demultiplexer associated with the amplifier.

    amp:location_id

    dcm:location_id

    md:location_id

    where location_id is the equipment location identifier for the module. See Location Identifiers.

    degreenum

    This specifies the degree to route the wavelength.

    1 to 4

    Note: Only 1 degree is supported.

    None

    groupnum

    This associates the module to an optical layer group.

    1 to 255

    None

    Required Privilege Level

    Sample Output

    The following example configures the 96-Channel Amplifier and associates a DCM with that module:

    bti7800(config)# amp eqpt amp:1/6 degreenum 1
    bti7800(config-eqpt-amp:1/6)# groupnum 1 
    bti7800(config-eqpt-amp:1/6)# exit 
    bti7800(config)# amp eqpt dcmeqpt:0/15 degreenum 1 
    bti7800(config-eqpt-dcmeqpt:0/15)# groupnum 1 
    bti7800(config-eqpt-dcmeqpt:0/15)# exit 
    bti7800(config)# commit 
    Commit complete.