Related Documentation
- None
equipment
Syntax
Description
This command configures equipment on the system. If the specified equipment does not exist, the specified equipment is added.
Options
Parameter | Description | Range | Default Value |
---|---|---|---|
chassis_id | See equipment chassis. | ||
passive_equip_id | The passive equipment identifier. Note: When you add a FMD96, the DOL ports on the module are automatically added. | passive_equip_id:
See Slot Identifier Ranges for the slot range. | None |
alias string | A user-defined name for the passive module | A character string. | An empty string |
custom1, custom2, custom3 string | Customizable text field for operator's use | 0 to 255 characters. | An empty string |
location string | The physical location of the passive module | A character string. | An empty string |
pec pec | The product equipment code for the passive module Note: This parameter is mandatory. | pec:
| None |
Required Privilege Level
Related Documentation
- None
Sample Output
The following creates a 96-Channel DWDM Mux/Demux:
bti7800(config)# equipment muxdemux:0/5 pec BT8A96MD01
bti7800(config-equipment-muxdemux:0/5)# commit Commit complete.