    equipment chassis module

    Syntax

    [no] equipment chassis_id module module_id [ admin-status status | custom1 string | custom2 string | custom3 string | pec pec ]

    Description

    This command sets parameters for the specified module. If the module does not exist, the module is created.

    Options

    Parameter

    Description

    Range

    Default Value

    chassis_id

    The chassis identifier

    chassis_id:

    • Main chassis (hub): chassis:1
    • Satellite chassis: chassis:2

    None

    module module_id

    The module identifier

    module_id:

    The slot range depends on the module and the chassis type. See Slot Identifier Ranges.

    None

    admin-status status

    Sets the administrative status of the module

    status:

    • up
    • down
    • testing (not supported)

    up

    custom1, custom2, custom3 string

    Customizable text field for operator's use

    0 to 255 characters

    An empty string

    pec pec

    The module product equipment code

    Note: This parameter is mandatory for most modules.

    A pre-defined product code

    None

    Required Privilege Level

     

    Related Documentation

     

    Sample Output

    The following adds a WPS4:

    bti7800(config)# equipment chassis:2 module wps:1/2 pec BT8A78WPS4
    bti7800(config-module-wps:1/2)# commit 
    Commit complete.

    Modified: 2017-03-10