    equipment chassis module roadm

    Syntax

    [no] equipment chassis_id module module_id [ admin-status status | custom1 string | custom2 string | custom3 string | pec pec | preamplifier preamplifier_id | roadm-card-type type ]

    Description

    This command sets parameters for the specified ROADM module. If the ROADM module does not yet exist, the ROADM module is created.

    Options

    Parameter

    Description

    Range

    Default Value

    chassis_id

    The chassis identifier

    chassis_id:

    • Main chassis (hub): chassis:1
    • Satellite chassis: chassis:2

    None

    module module_id

    The ROADM module identifier

    module_id

    • roadm:chassis/slot

    None

    admin-status status

    The administrative status of the module

    status:

    • up
    • down
    • testing (not supported)

    up

    custom1, custom2, custom3 string

    Customizable text field for operator's use

    0 to 255 characters

    An empty string

    pec pec

    The ROADM product equipment code

    A pre-defined product code. You can set this attribute directly or you can let the system set this attribute automatically when you configure the roadm-card-type.

    None

    preamplifier preamplifier_id

    The preamplifier identifier

    Specify only if you are adding a PRE module.

    preamplifier_id:

    • pre:chassis/slot/1

    None

    roadm-card-type type

    The ROADM type

    type:

    • 2-port: ROADM2
    • 9-port (not supported)
    • 20-port (not supported)

    None

    Additional Information

    The following are automatically created when you create a ROADM module:

    • DOL client, line, and PRE ports
    • DOL optical multiplex sections (OMS) for the client and line ports
    • DOL optical service channels (OSC) for the client and line ports

    Required Privilege Level

     

    Related Documentation

     

    Sample Output

    The following creates a ROADM2 module (output truncated for clarity):

    bti7800(config)# equipment chassis:1 module roadm:1/6
    Value for 'roadm-card-type' [2-port,8-port,20-port]: 2-port 
    bti7800(config-module-roadm:1/6)# commit 
    Commit complete. 
    
    bti7800(config-module-roadm:1/6)# do show dol
    Dynamic Optical Layer Ports 
    ---------------------------  
    
    Port Name           Span Length  OL Id               Custom1  Custom2  Custom3
    ------------------  -----------  ------------------  -------  -------  -------
    port:1/6/0/C1 
    port:1/6/0/C2 
    port:1/6/0/L1 
    port:1/6/0/PRE  
    
    Dynamic Optical Layer Optical Multiplex Sections 
    ------------------------------------------------  
    
    Oms Name       Admin State  Oper State  PreAmp State    OL Id   Custom1  Custo 
    -------------  -----------  ----------  --------------  ------  -------  ----- 
    oms:1/6/0/C1   enabled      unknown     Not Applicable 
    oms:1/6/0/C2   enabled      unknown     Not Applicable 
    oms:1/6/0/L1   enabled      unknown     disabled  
    
    Dynamic Optical Layer Optical Service Channels 
    ----------------------------------------------  
    
    OSC Name        Admin State  Oper State  OL Id       Custom1  Custom2  Custom3 
    --------------  -----------  ----------  ----------  -------  -------  ------- 
    osc:1/6/0/C1    enabled      unknown 
    osc:1/6/0/C2    enabled      unknown 
    osc:1/6/0/L1    enabled      unknown 