amp eqpt-conn
Syntax
Description
This command configures intra-group optical fiber patch connections between the amplifier and multiplexer/demultiplexer, DCM, and ROADM line ports.
Options
Required Privilege Level
Sample Output
This example assumes that the 96-Channel Amplifier is configured and a DCM and multiplexer/demultiplexer are associated with the amplifier. Refer to the example for the command amp eqpt.
The following example configures a fiber patch connection between the 96-Channel Amplifier, a DCM and Mux/Demux:
The export value represents the configured DCM ID 0/1, and is considered the Source port.
The line value represents the configured Mux/Demux ID 0/2, and is considered the Destination port.
bti7800(config)# amp eqpt-conn dcm:1/8/1/1
export:0/1/1/1
bti7800(config-eqpt-conn-dcm:1/8/1/1/export:0/1/1/1)# commit Commit complete. bti7800(config)# amp eqpt-conn client:1/8/1/1 line:0/2/1/1 bti7800(config-eqpt-conn-client:1/8/1/1/line:0/2/1/1)# exit bti7800(config)# commit Commit complete.