    This section lists the event policies present in an AI-Scripts package. The event policies monitor occurrence of events (abnormal conditions) in a device. The event policies have .slax extension and are stored in the /var/db/scripts/event folder when AI-Scripts are installed on a device.

    Structured Event Policies

    Table 1 lists the event policies for structured Junos OS log messages. The event policies have *.slax extension.

    Table 1: Structured Events Detected by AI-Scripts

    Event Policy File Name

    Event Matching Pattern Used for the Service Now Event Synopsis

    Description

    ACCT_MALLOC_FAILURE.slax

    ACCT_MALLOC_FAILURE

    The accounting statistics process could not allocate memory from the heap.

    ACCT_XFER_POPEN_FAIL.slax

    ACCT_XFER_POPEN_FAIL

    The popen() function fails when the accounting statistics process invokes the indicated command to transfer the indicated file.

    ASP_IDS_INV_CLEAR_QUERY.slax

    ASP_IDS_INV_CLEAR_QUERY

    The intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request includes the indicated type of query, which the IDS cannot interpret.

    ASP_IDS_INV_CLEAR_QUERY_VER.slax

    ASP_IDS_INV_CLEAR_QUERY_VER

    The intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request version number did not match the version number of requests that the IDS can service.

    ASP_L2TP_NO_MEM.slax

    ASP_L2TP_NO_MEM

    The Layer 2 Tunneling Protocol (L2TP) could not allocate the memory it needed to create a flow for the indicated tunnel and session.

    ASP_L2TP_OBJ_CAC_FAIL.slax

    ASP_L2TP_OBJ_CAC_FAIL

    The Layer 2 Tunneling Protocol (L2TP) could not allocate memory from an object cache for the flow defined by the indicated unit, tunnel, and session.

    ASP_PGCP_IPC_MSG_WRITE_FAILED.slax

    ASP_PGCP_IPC_MSG_WRITE_FAILED

    The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write an interprocess communication (IPC) message to the end of its pipe.

    ASP_PGCP_IPC_PIPE_WRITE_FAILED.slax

    ASP_PGCP_IPC_PIPE_WRITE_FAILED

    The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write the contents of its interprocess communication (IPC) pipe to the socket layer.

    AUDITD_RADIUS_OPEN_FAILED.slax

    AUDITD_RADIUS_OPEN_FAILED

    The audit process (auditd) could not create a RADIUS object handle used for various RADIUS operations.

    AUDITD_RADIUS_REQ_CREATE_FAILED.slax

    AUDITD_RADIUS_REQ_CREATE_FAILED

    The audit process (auditd) could not create a RADIUS accounting request for the indicated reason.

    AUDITD_SOCKET_FAILURE.slax

    AUDITD_SOCKET_FAILURE

    The audit process (auditd) listens on a Transmission Control Protocol (TCP) socket for system accounting events reported by other processes on the device. The indicated socket operation failed with the indicated error.

    AUTHD_AUTH_CREATE_FAILED.slax

    AUTHD_AUTH_CREATE_FAILED

    The generic authentication service process (authd) could not allocate an authentication object for the indicated reason.

    AUTHD_SERVER_INIT_BIND_FAIL.slax

    AUTHD_SERVER_INIT_BIND_FAIL

    The generic authentication service process (authd) could not bind the server to the address specified.

    AUTHD_SERVER_INIT_LISTEN_FAIL.slax

    AUTHD_SERVER_INIT_LISTEN_FAIL

    The generic authentication service process (authd) could not initialize listening on the server for the indicated socket.

    AUTHD_SETSOCKOPT_FAILED.slax

    AUTHD_SETSOCKOPT_FAILED

    The generic authentication service process (authd) could not set socket options during the indicated operation.

    AUTHD_SOCKET_FAILED.slax

    AUTHD_SOCKET_FAILED

    The generic authentication service process (authd) could not open a socket during the indicated operation.

    AUTOCONFD_AUTH_NO_MEM.slax

    AUTOCONFD_AUTH_NO_MEM

    Memory allocation (malloc) for username authentication failed.

    AUTOD_RECV_FAILURE.slax

    AUTOD_RECV_FAILURE

    The autoinstallation process (autod) receives the indicated error when it tries to receive data on a socket.

    AUTOD_SEND_FAILURE.slax

    AUTOD_SEND_FAILURE

    The autoinstallation process (autod) receives the indicated error when it sends data on a socket.

    AUTOD_SOCKET_CREATE_FAILURE.slax

    AUTOD_SOCKET_CREATE_FAILURE

    The autoinstallation process (autod) receives the indicated error when it creates a socket.

    AV_PATTERN_KL_CHECK_FAILED.slax

    AV_PATTERN_KL_CHECK_FAILED

    The device is unable to use the Kaspersky pattern file. The error message provides information to give to Juniper Networks technical support.

    AV_PATTERN_TOO_BIG.slax

    AV_PATTERN_TOO_BIG

    The pattern file size specified in the server initialization file (server.ini) exceeds the maximum prescribed limit.

    AV_PATTERN_WRITE_FS_FAILED.slax

    AV_PATTERN_WRITE_FS_FAILED

    The device is unable to save the contents of an antivirus pattern file to the file system.

    BFDD_READ_ERROR.slax

    BFDD_READ_ERROR

    The bidirectional forwarding detection process (bfdd) could not read a message available on the indicated type of pipe.

    BFDD_WRITE_ERROR.slax

    BFDD_WRITE_ERROR

    The bidirectional forwarding detection process (bfdd) could not write a message to the indicated type of pipe.

    BOOTPD_HWDB_ERROR.slax

    BOOTPD_HWDB_ERROR

    The boot parameter process (tnp.bootpd) could not complete an operation in the hardware database maintained by the chassis process (chassisd), for the indicated reason.

    CFMD_RTSOCK_OPEN_FAILURE.slax

    CFMD_RTSOCK_OPEN_FAILURE

    The connectivity fault management process (cfmd) could not successfully open a routing socket to the kernel, for the indicated reason.

    CHASSISD_BUS_DEVICE_OPEN_FAILURE.slax

    CHASSISD_BUS_DEVICE_OPEN_FAILURE

    The chassis process (chassisd) could not open the indicated bus device, for the indicated reason.

    CHASSISD_CFEB_POWER_FAILURE.slax

    CHASSISD_CFEB_POWER_FAILURE

    The chassis process (chassisd) could not turn on or turn off the power to the indicated Compact Forwarding Engine Board (CFEB).

    CHASSISD_CLOCK_FAILURE.slax

    CHASSISD_CLOCK_FAILURE

    The chassis process (chassisd) determined that the indicated clock source failed in the indicated way.

    CHASSISD_CMB_READBACK_ERROR.slax

    CHASSISD_CMB_READBACK_ERROR

    The chassis process (chassisd) could not read back information from the chassis management bus (CMB) about the indicated component (field-replaceable unit, or FRU).

    CHASSISD_COMMAND_ACK_ERROR.slax

    CHASSISD_COMMAND_ACK_ERROR

    The chassis process requested that the indicated component (field-replaceable unit, or FRU) confirm that it was online. The indicated error occurred when the FRU sent its response. In the normal case, the chassis process performs any additional action necessary to guarantee that the FRU comes online.

    CHASSISD_COMMAND_ACK_SFM_ERROR.slax

    CHASSISD_COMMAND_ACK_SFM_ERROR

    The chassis process (chassisd) requires an acknowledgment from each Switching and Forwarding Module (SFM) before it registers a Flexible PIC Controller (FPC) as online. The acknowledgment message from the indicated SFM failed for the indicated FPC.

    CHASSISD_FAN_FAILURE.slax

    CHASSISD_FAN_FAILURE

    The indicated fan or impeller failed. The chassis process (chassisd) raised an alarm and increased the speed of the remaining fans (and impellers, if applicable) to full speed.

    CHASSISD_FASIC_FTOKEN_ERROR.slax

    CHASSISD_FASIC_FTOKEN_ERROR

    The chassis process (chassisd) detected an underflow or overflow error on the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_FTOKEN_INIT_ERROR.slax

    CHASSISD_FASIC_FTOKEN_INIT_ERROR

    The chassis process (chassisd) encountered an error while initializing memory at the indicated address for the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_HSL_CONFIG_ERROR.slax

    CHASSISD_FASIC_HSL_CONFIG_ERROR

    The chassis process (chassisd) could not configure high-speed links for the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_HSL_LINK_ERROR.slax

    CHASSISD_FASIC_HSL_LINK_ERROR

    The chassis process (chassisd) detected an error for the indicated high-speed link (HSL) for the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_INIT_ERROR.slax

    CHASSISD_FASIC_INIT_ERROR

    The chassis process (chassisd) detected that F-chips were not yet initialized on the Control Board (CB).

    CHASSISD_FASIC_INPUT_DROP.slax

    CHASSISD_FASIC_INPUT_DROP

    The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F-chip on the indicated Control Board (CB) processed data that was received from the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per second.

    CHASSISD_FASIC_OUTPUT_DROP.slax

    CHASSISD_FASIC_OUTPUT_DROP

    The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F-chip on the indicated Control Board (CB) processed data before sending it to the indicated Packet Forwarding Engine on the indicated Flexible Port Concentrator (FPC) for outgoing transmission, it dropped the indicated number of cells per second.

    CHASSISD_FASIC_PIO_READ_ERROR.slax

    CHASSISD_FASIC_PIO_READ_ERROR

    The chassis process (chassisd) has detected a read error on a fabric link

    CHASSISD_FASIC_PIO_WRITE_ERROR.slax

    CHASSISD_FASIC_PIO_WRITE_ERROR

    The chassis process (chassisd) has detected a write error on a fabric link

    CHASSISD_FASIC_PLL_ERROR.slax

    CHASSISD_FASIC_PLL_ERROR

    The chassis process (chassisd) could not lock a phased-lock loop (PLL) for the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_RESET_ERROR.slax

    CHASSISD_FASIC_RESET_ERROR

    The chassis process (chassisd) could not reset the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FASIC_SRAM_ERROR.slax

    CHASSISD_FASIC_SRAM_ERROR

    The chassis process (chassisd) detected that SRAM failed to initialize for the indicated F-chip on the indicated Control Board (CB).

    CHASSISD_FCHIP_CONFIG_MD_ERROR.slax

    CHASSISD_FCHIP_CONFIG_MD_ERROR

    The chassis process (chassisd) detected an invalid number of MD-chips for the indicated F-chip, Packet Forwarding Engine, and Flexible PIC Concentrator (FPC).

    CHASSISD_FCHIP_HSR_ERROR.slax

    CHASSISD_FCHIP_HSR_ERROR

    The chassis process (chassisd) detected an error in the high-speed receiver (HSR) subsystem for the F-chip with the indicated characteristics.

    CHASSISD_FCHIP_HST_ERROR.slax

    CHASSISD_FCHIP_HST_ERROR

    The chassis process (chassisd) detected an error in the high-speed transmitter (HST) subsystem for the F-chip with the indicated characteristics.

    CHASSISD_FCHIP_LINK_ERROR.slax

    CHASSISD_FCHIP_LINK_ERROR

    The chassis process (chassisd) detected an error for the indicated high-speed receiver (HSR) or high-speed transmitter (HST) link for an F-chip on the indicated Switch Interface Board (SIB).

    CHASSISD_FCHIP_MONITOR_ERROR.slax

    CHASSISD_FCHIP_MONITOR_ERROR

    The chassis process (chassisd) detected an invalid F-chip module while enabling or disabling the monitoring of F-chip functional blocks.

    CHASSISD_FCHIP_PIO_READ_ERROR.slax

    CHASSISD_FCHIP_PIO_READ_ERROR

    A routine encountered an error while reading an F-chip register

    CHASSISD_FCHIP_PIO_WRITE_ERROR.slax

    CHASSISD_FCHIP_PIO_WRITE_ERROR

    A routine encountered an error while writing to an F-chip

    CHASSISD_FEB_SWITCHOVER.slax

    CHASSISD_FEB_SWITCHOVER

    The chassis daemon (chassisd) switched to the indicated FEB from the specified FEB.

    CHASSISD_FHSR_READ_REG_ERROR.slax

    CHASSISD_FHSR_READ_REG_ERROR

    The high-speed receiver (HSR) read routine failed at the indicated address on an F-chip register.

    CHASSISD_FHSR_WRITE_REG_ERROR.slax

    CHASSISD_FHSR_WRITE_REG_ERROR

    The high-speed receiver (HSR) write routine could not record the indicated value at the indicated address on an F-chip register.

    CHASSISD_FHST_READ_REG_ERROR.slax

    CHASSISD_FHST_READ_REG_ERROR

    The high-speed transmitter (HST) read routine failed at the indicated address on an F-chip register.

    CHASSISD_FHST_WRITE_REG_ERROR.slax

    CHASSISD_FHST_WRITE_REG_ERROR

    The high-speed transmitter (HST) write routine could not record the indicated value at the indicated address on an F-chip register.

    CHASSISD_FILE_OPEN.slax

    CHASSISD_FILE_OPEN

    The chassis process (chassisd) could not open the indicated file for the indicated reason.

    CHASSISD_FM_ERROR.slax

    CHASSISD_FM_ERROR

    During the execution of the indicated fabric management routine, the indicated error occurred between the indicated Switch Interface Board (SIB) and the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC).

    CHASSISD_FM_ERROR_F13_FB_HSR_TXP.slax

    CHASSISD_FM_ERROR_F13_FB_HSR_TXP

    In a TX Matrix Plus router, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected an error in the electrical path between the indicated ports on the F13SIB and the indicated ST-SIB-L on the indicated LCC.

    CHASSISD_FM_ERROR_F13_FB_RX_VC.slax

    CHASSISD_FM_ERROR_F13_FB_RX_VC

    In a TX Matrix Plus router matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the optical media from the indicated ST-SIB-L on the indicated LCC.

    CHASSISD_FM_ERROR_F13_FB_TX_VC.slax

    CHASSISD_FM_ERROR_F13_FB_TX_VC

    In a TX Matrix Plus router, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

    CHASSISD_FM_ERROR_SIB_L_FB_HSR.slax

    CHASSISD_FM_ERROR_SIB_L_FB_HSR

    In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T640 router (called SIB-Ls) and the SIBs in the TX Matrix platform (called SIB-Ss). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected an error in the electrical path between the indicated ports on the SIB-L and the corresponding SIB-S.

    CHASSISD_FM_ERROR_SIB_L_FB_SMF.slax

    CHASSISD_FM_ERROR_SIB_L_FB_SMF

    In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix (the switch-card chassis, or SCC) and the SIBs in the T640 routers (called SIB-Ls). The chassis process (chassisd) on the T640 router that houses the indicated SIB-L detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

    CHASSISD_FM_ERROR_SIB_S_FB_HSR.slax

    CHASSISD_FM_ERROR_SIB_S_FB_HSR

    In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routers (called SIB-Ls). The chassis process (chassisd) on the TX Matrix router has detected an error in the electrical path between the indicated port on the indicated SIB-S and the indicated port on a SIB-L installed in the indicated T640 router (line-card chassis, or LCC).

    CHASSISD_FM_ERROR_SIB_S_FB_SMF.slax

    CHASSISD_FM_ERROR_SIB_S_FB_SMF

    In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix routers (called SIB-Ss) and the SIBs in the T640 routers (line-card chassis, or LCCs). The chassis process (chassisd) on the TX Matrix platform detected the indicated error as packets that were traveling to or from the indicated LCC were translated between electrical and optical media.

    CHASSISD_FM_SIB_ERROR.slax

    CHASSISD_FM_SIB_ERROR

    The chassis process (chassisd) detected the indicated type of error on the indicated Switch Interface Board (SIB) and performed the indicated action.

    CHASSISD_FPC_PIC_DETECT_TIMEOUT.slax

    CHASSISD_FPC_PIC_DETECT_TIMEOUT

    The chassis process (chassisd) expects to receive notification within a timeout period that each Flexible PIC Concentrator (FPC) has attached the PIC that it houses. It did not receive notification from the indicated FPC.

    CHASSISD_FRU_INVALID_SLOT.slax

    CHASSISD_FRU_INVALID_SLOT

    The chassis process (chassisd) detected that the indicated hardware component (field-replaceable unit, or FRU) was inserted in a slot that is not valid for that component type.

    CHASSISD_FRU_IO_ERROR.slax

    CHASSISD_FRU_IO_ERROR

    The chassis process (chassisd) could not perform the indicated I/O operation on the indicated component (field-replaceable unit, or FRU).

    CHASSISD_FRU_OFFLINE_NOTICE.slax

    CHASSISD_FRU_OFFLINE_NOTICE

    The chassis process (chassisd) took the indicated component (field-replaceable unit, or FRU) offline for the indicated reason.

    CHASSISD_GBUS_NOT_READY.slax

    CHASSISD_GBUS_NOT_READY

    The GBUS was not ready when the chassis process (chassisd) first tried to power it on, and the power-up operation timed out.

    CHASSISD_GBUS_READBACK_ERROR.slax

    CHASSISD_GBUS_READBACK_ERROR

    There was an error when the chassis process (chassisd) tried to read back information from the GBUS on the indicated component (field-replaceable unit, or FRU).

    CHASSISD_HSR_FIFO_ERROR.slax

    CHASSISD_HSR_FIFO_ERROR

    A first-in, first-out (FIFO) read error occurred during execution of the indicated routine on the indicated high-speed receiver (HSR).

    CHASSISD_HWDB_ERROR.slax

    CHASSISD_HWDB_ERROR

    The operation performed on the hardware database was unsuccessful.

    CHASSISD_I2C_BAD_IDEEPROM_FORMAT.slax

    CHASSISD_I2C_BAD_IDEEPROM_FORMAT

    The chassis process (chassisd) determined that the ID EEPROM format specified for the indicated type of hardware component (field-replaceable unit, or FRU) is not valid for it.

    CHASSISD_I2C_READ_ERROR.slax

    CHASSISD_I2C_READ_ERROR

    The chassis process (chassisd) cannot read I2C data from the indicated device.

    CHASSISD_I2CS_READBACK_ERROR.slax

    CHASSISD_I2CS_READBACK_ERROR

    The chassis process (chassisd) cannot read back information from the I2C slave (I2CS) about the indicated component (field-replaceable unit, or FRU).

    CHASSISD_IFDEV_DETACH_FPC.slax

    CHASSISD_IFDEV_DETACH_FPC

    The chassis process (chassisd) detached the interface devices for all PICs on the indicated Flexible PIC Concentrator (FPC).

    CHASSISD_IFDEV_DETACH_PIC.slax

    CHASSISD_IFDEV_DETACH_PIC

    The chassis process (chassisd) detached the interface devices for the indicated PIC.

    CHASSISD_IFDEV_GET_BY_NAME_FAIL.slax

    CHASSISD_IFDEV_GET_BY_NAME_FAIL

    The chassis process (chassisd) could not obtain information about the indicated interface.

    CHASSISD_IPC_CONNECTION_DROPPED.slax

    CHASSISD_IPC_CONNECTION_DROPPED

    The chassis process (chassisd) dropped the interprocess communication (IPC) connection to the indicated component (field-replaceable unit, or FRU).

    CHASSISD_IPC_DAEMON_WRITE_ERROR.slax

    CHASSISD_IPC_DAEMON_WRITE_ERROR

    The chassis process (chassisd) could not write to a socket because of the indicated error. The socket is for a connection to another process that runs on the Routing Engine and helps manage the chassis.

    CHASSISD_IPC_MSG_DROPPED.slax

    CHASSISD_IPC_MSG_DROPPED

    The chassis process (chassisd) dropped an interprocess communication (IPC) message because the message queue had already reached maximum capacity.

    CHASSISD_IPC_MSG_UNHANDLED.slax

    CHASSISD_IPC_MSG_UNHANDLED

    The chassis process (chassisd) received an interprocess communication (IPC) message about the indicated FRU. The message had the indicated characteristics. chassisd could not handle the message.

    CHASSISD_IPC_WRITE_ERR_NULL_ARGS.slax

    CHASSISD_IPC_WRITE_ERR_NULL_ARGS

    The chassis process (chassisd) could not send a message to the indicated component (field-replaceable unit, or FRU) because one or more required parameters had a null value.

    CHASSISD_ISSU_ERROR.slax

    CHASSISD_ISSU_ERROR

    The chassis process (chassisd) encountered an error during the In Service Software Upgrade Process.

    CHASSISD_MAC_ADDRESS_ERROR.slax

    CHASSISD_MAC_ADDRESS_ERROR

    The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated interface because of an internal error.

    CHASSISD_MAC_ADDRESS_FABRIC_ERROR.slax

    CHASSISD_MAC_ADDRESS_FABRIC_ERROR

    The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated fabric interface because of an internal error.

    CHASSISD_MALLOC_FAILURE.slax

    CHASSISD_MALLOC_FAILURE

    The chassis process (chassisd) could not allocate memory. chassisd tried to continue functioning, but the lack of memory usually causes the process to fail. An administrator needs to restart it.

    CHASSISD_MBE_DETECTED.slax

    CHASSISD_MBE_DETECTED

    A multibit ECC parity error was detected in the Routing Engine DRAM.

    CHASSISD_OVER_TEMP_CONDITION.slax

    CHASSISD_OVER_TEMP_CONDITION

    The temperature of one or more components (field-replaceable units, or FRUs) exceeded the indicated temperature, which is the upper of two thresholds. The fans (and impellers, if applicable) were in the indicated state. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, chassisd shuts down the device. When this message was logged, the indicated number of seconds remained before shutdown.

    CHASSISD_OVER_TEMP_SHUTDOWN_TIME.slax

    CHASSISD_OVER_TEMP_SHUTDOWN_TIME

    The chassis process (chassisd) shut down the device because the temperature of one or more components exceeded the indicated threshold temperature for the indicated amount of time. Continued operation at the excessive temperature could damage the device.

    CHASSISD_PEM_INPUT_BAD.slax

    CHASSISD_PEM_INPUT_BAD

    The chassis process (chassisd) detected the indicated error condition for the indicated power entry module (PEM).

    CHASSISD_PEM_OVERLOAD.slax

    CHASSISD_PEM_OVERLOAD

    The indicated power entry module (PEM) reported an output voltage overload condition.

    CHASSISD_PEM_TEMPERATURE.slax

    CHASSISD_PEM_TEMPERATURE

    The chassis process (chassisd) detected that the 'temperature check bit' was set in the status bit mask for the indicated power entry module (PEM).

    CHASSISD_PEM_VOLTAGE.slax

    CHASSISD_PEM_VOLTAGE

    The indicated power entry module (PEM) reported a problem with its output voltage.

    CHASSISD_PIC_HWERROR.slax

    CHASSISD_PIC_HWERROR

    The indicated PIC experienced a hardware error. The chassis process (chassisd) did not bring the PIC online.

    CHASSISD_POWER_CHECK.slax

    CHASSISD_POWER_CHECK

    The chassis process (chassisd) could not power up the indicated component (field-replaceable unit, or FRU), because the FRU did not respond.

    CHASSISD_PSU_ERROR.slax

    CHASSISD_PSU_ERROR

    The chassis process (chassisd) detected the indicated error condition for the indicated power supply unit (PSU).

    CHASSISD_PSU_FAN_FAIL.slax

    CHASSISD_PSU_FAN_FAIL

    The PSU fan-fail bit is set in the status for the indicated power supply unit (PSU).

    CHASSISD_PSU_INPUT_BAD.slax

    CHASSISD_PSU_INPUT_BAD

    The chassis process (chassisd) detected the input voltage/warning fault condition for the indicated power supply unit (PSU).

    CHASSISD_PSU_OVERLOAD.slax

    CHASSISD_PSU_OVERLOAD

    The indicated power supply unit (PSU) reported an output voltage overload condition.

    CHASSISD_PSU_TEMPERATURE.slax

    CHASSISD_PSU_TEMPERATURE

    The chassis process (chassisd) detected that the temperature check bit was set in the status bit mask for the indicated power supply unit (PSU).

    CHASSISD_PSU_VOLTAGE.slax

    CHASSISD_PSU_VOLTAGE

    The indicated power supply unit (PSU) reported a problem with its output voltage.

    CHASSISD_RE_OVER_TEMP_CONDITION.slax

    CHASSISD_RE_OVER_TEMP_CONDITION

    The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds.

    CHASSISD_RE_OVER_TEMP_SHUTDOWN.slax

    CHASSISD_RE_OVER_TEMP_SHUTDOWN

    The chassis process (chassisd) performed the indicated action because the temperature of the indicated Routing Engine exceeded the maximum threshold for more than four minutes. Continued operation at the excessive temperature could damage device components.

    CHASSISD_RE_OVER_TEMP_WARNING.slax

    CHASSISD_RE_OVER_TEMP_WARNING

    The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, chassisd shuts down the indicated component. When this message was logged, the indicated number of seconds remained before shutdown.

    CHASSISD_SBE_DETECTED.slax

    CHASSISD_SBE_DETECTED

    Too many single-bit correctable ECC parity errors were detected in the Routing Engine DRAM.

    CHASSISD_SHUTDOWN_NOTICE.slax

    CHASSISD_SHUTDOWN_NOTICE

    Although the chassis process (chassisd) normally does not exit or shut down except when the Routing Engine reboots, it shut down for the indicated reason.

    CHASSISD_SIB_INVALID_SLOT.slax

    CHASSISD_SIB_INVALID_SLOT

    The chassis process (chassisd) detected the presence of a Switch Interface Board (SIB) in an invalid slot. The SIB remains offline.

    CHASSISD_SIGPIPE.slax

    CHASSISD_SIGPIPE

    The chassis process (chassisd) received a signal indicating that its attempt to write to a pipe failed because the reader (which could be another process or thread) did not exist.

    CHASSISD_SMB_INVALID_PS.slax

    CHASSISD_SMB_INVALID_PS

    The chassis process (chassisd) could not set the status (enabled or disabled) for a power supply because it received the indicated power supply status code, which is invalid.

    CHASSISD_SMB_IOCTL_FAILURE.slax

    CHASSISD_SMB_IOCTL_FAILURE

    The indicated ioctl() operation failed at the indicated address on the system management bus (SMB).

    CHASSISD_SMB_READ_FAILURE.slax

    CHASSISD_SMB_READ_FAILURE

    A read() operation failed at the indicated address on the system management bus (SMB).

    CHASSISD_SNMP_TRAP6.slax

    CHASSISD_SNMP_TRAP6

    The device sent a CHASSISD_SNMP_TRAP6 trap for a Power Supply Failed event.

    CHASSISD_TEMP_SENSOR_FAILURE.slax

    CHASSISD_TEMP_SENSOR_FAILURE

    The temperature sensor for the indicated component (field-replaceable unit, or FRU) either did not respond to a request from the chassis process (chassisd) for a temperature reading or sent a value that is outside the normal operating range.

    CHASSISD_TIMER_VAL_ERR.slax

    CHASSISD_TIMER_VAL_ERR

    The chassis process (chassisd) started a timer to track the timeout period for an event. The timer returned a null identifier, so chassisd could not clear the timer.

    CHASSISD_UNEXPECTED_EXIT.slax

    CHASSISD_UNEXPECTED_EXIT

    The chassis process (chassisd) exited unexpectedly and reported the indicated error.

    CHASSISD_VOLTAGE_READ_FAILED.slax

    CHASSISD_VOLTAGE_READ_FAILED

    The chassis process (chassisd) could not read the voltage data from the indicated component (field-replaceable unit, or FRU).

    CHASSISD_VOLTAGE_SENSOR_INIT.slax

    CHASSISD_VOLTAGE_SENSOR_INIT

    The chassis process (chassisd) could not initialize the voltage sensor for the indicated component (field-replaceable unit, for FRU).

    CONNECTION_CHASSISD_FAIL.slax

    CONNECTION_CHASSISD_FAIL

    The alarm process (alarmd) was unable to connect to the chassis process (chassisd).

    CONNECTION_CRAFTD_FAIL.slax

    CONNECTION_CRAFTD_FAIL

    The alarm process (alarmd) was unable to connect to the craft process (craftd).

    CONNECTION_RTLOGD_FAIL.slax

    CONNECTION_RTLOGD_FAIL

    The alarm process (alarmd) was unable to connect to the Juniper Networks J Series Services Router (JSR) log process (rtlogd).

    CONNECTION_SEND_ERROR.slax

    CONNECTION_SEND_ERROR

    The alarm process (alarmd) received an error while it was trying to send a message.

    COSD_GENCFG_WRITE_FAILED.slax

    COSD_GENCFG_WRITE_FAILED

    The class-of-service (CoS) process (cosd) uses GENCFG to read and write data from the kernel. If the write fails, the kernel returns an error.

    COSD_MALLOC_FAILED.slax

    COSD_MALLOC_FAILED

    The class-of-service (CoS) process (cosd) could not dynamically allocate memory, for the indicated reason.

    COSD_RTSOCK_LIB_ERR.slax

    COSD_RTSOCK_LIB_ERR

    The class-of-service (CoS) process (cosd) uses rtsock library for reading and writing data from and to kernel. The specified error occurred while using rtsock library to read or write data.

    COSD_RTSOCK_WRITE_FAILED.slax

    COSD_RTSOCK_WRITE_FAILED

    The class-of-service (CoS) process (cosd) uses rtsock to read or write data from kernel. If the write fails kernel returns an error.

    COSD_UNEXPECTED_EXIT.slax

    COSD_UNEXPECTED_EXIT

    The class-of-service (CoS) process (cosd) waits for the event notifications and processes the events that it is registered for. There was an error during event-handling initialization.

    COSD_UNKNOWN_TRANSLATION_TABLE.slax

    COSD_UNKNOWN_TRANSLATION_TABLE

    The class-of-service (CoS) process (cosd) did not recognize the indicated translation table type from the rtsock library.

    DCD_CONFIG_WRITE_FAILED.slax

    DCD_CONFIG_WRITE_FAILED

    The interface process (dcd) encountered an error while trying to send an interface configuration to the kernel over the routing socket.

    DCD_GET_ERROR.slax

    DCD_GET_ERROR

    The interface process (dcd) encountered an error while trying to load the kernel interface configuration over the routing socket.

    DCD_PARSE_STATE_EMERGENCY.slax

    DCD_PARSE_STATE_EMERGENCY

    The interface process (dcd) encountered an unhandled internal state during interface parsing.

    DCD_RTSOCK_READ_SYNC_NOBUF.slax

    DCD_RTSOCK_READ_SYNC_NOBUF

    The interface process (dcd) communicates with the kernel by writing messages to and reading messages from routing sockets. The dcd could not allocate memory to use to read messages from the kernel.

    DCD_RTSOCK_SEND_NOBUF.slax

    DCD_RTSOCK_SEND_NOBUF

    If the Routing Engine is busy or operating under a heavy load, messages between the interface process (dcd) and the kernel may be dropped. To detect whether messages have been dropped, dcd and the kernel place sequence numbers in messages. dcd detected that a message was dropped. In an attempt to recover the message, dcd retries the operation.

    DCD_TRASHED_RED_ZONE.slax

    DCD_TRASHED_RED_ZONE

    When the interface process (dcd) is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when deallocating this memory, dcd checks for the pattern. Not finding the previously written pattern means the memory was overwritten, which indicates an error in dcd.

    DFCD_GENCFG_MALLOC_FAILED.slax

    DFCD_GENCFG_MALLOC_FAILED

    The dynamic flow capture process (dfcd) could not allocate memory for the GENCFG message.

    DFCD_GENCFG_WRITE_FAILED.slax

    DFCD_GENCFG_WRITE_FAILED

    The dynamic flow capture process (dfcd) could not send the GENCFG message for the indicated reason.

    DFCD_LINH_MALLOC_FAILED.slax

    DFCD_LINH_MALLOC_FAILED

    The dynamic flow capture process (dfcd) could not allocate memory for the LINH message.

    DFWD_CONFIG_WRITE_FAILED.slax

    DFWD_CONFIG_WRITE_FAILED

    The firewall process (dfwd) encountered an error while trying to send an interface configuration to the kernel over the routing socket.

    DFWD_MALLOC_FAILED.slax

    DFWD_MALLOC_FAILED

    The firewall process (dfwd) must dynamically allocate memory for its needs. This allocation request failed. The specific data structure that was being allocated is listed in the message.

    DFWD_PARSE_STATE_EMERGENCY.slax

    DFWD_PARSE_STATE_EMERGENCY

    The firewall process (dfwd) encountered an unhandled internal state while parsing an interface.

    DFWD_TRASHED_RED_ZONE.slax

    DFWD_TRASHED_RED_ZONE

    When the firewall process (dfwd) is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when deallocating this memory, dfwd checks for the pattern. Not finding the previously written pattern means the memory was overwritten, which indicates an error in dfwd.

    DH_SVC_LOGIN_FAILURE.slax

    DH_SVC_LOGIN_FAILURE

    The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not log the client in with the indicated application and the indicated session ID on the indicated interface (interface name) due to the indicated failure (preauthentication or postauthentication failure).

    DH_SVC_RTSOCK_OPEN_FAILURE.slax

    DH_SVC_RTSOCK_OPEN_FAILURE

    The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error.

    DH_SVC_RTSOCK_REGISTER_FAILURE.slax

    DH_SVC_RTSOCK_REGISTER_FAILURE

    The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully register a callback function with a routing socket. The error string accompanying this log entry indicates the specific error.

    DH_SVC_SETSOCKOPT_FAILURE.slax

    DH_SVC_SETSOCKOPT_FAILURE

    The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not set the indicated socket option.

    DH_SVC_SOCKET_FAILURE.slax

    DH_SVC_SOCKET_FAILURE

    The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not create a socket.

    ESPTASK_PARSE_BAD_SWITCH.slax

    ESPTASK_PARSE_BAD_SWITCH

    This process terminated because of an invalid option.

    ESPTASK_PARSE_CMD_ARG.slax

    ESPTASK_PARSE_CMD_ARG

    This process terminated because of an internal error.

    ESPTASK_PARSE_CMD_EXTRA.slax

    ESPTASK_PARSE_CMD_EXTRA

    This process terminated because of an invalid option.

    ESWD_DAI_FAILED.slax

    ESWD_DAI_FAILED

    The ARP request/response received on this port cannot be linked to any of the IPs assigned by DHCP.

    ESWD_DHCP_UNTRUSTED.slax

    ESWD_DHCP_UNTRUSTED

    DHCP server packets are being received on a port that was not meant to receive server traffic.

    ESWD_PPM_READ_ERROR.slax

    ESWD_PPM_READ_ERROR

    The Ethernet bridging process (eswd) could not read a message available on the read pipe from the periodic packet management process (ppmd).

    ESWD_PPM_WRITE_ERROR.slax

    ESWD_PPM_WRITE_ERROR

    The Ethernet bridging process (eswd) could not write a message on the pipe to the periodic packet management process (ppmd).

    ESWD_ST_CTL_ERROR_IN_EFFECT.slax

    ESWD_ST_CTL_ERROR_IN_EFFECT

    This condition occurs when storm control error condition is detected.

    ESWD_STP_BASE_MAC_ERROR.slax

    ESWD_STP_BASE_MAC_ERROR

    This condition occurs when the STP cannot derive the base MAC address of the system.

    EVENTD_EVENT_SEND_FAILED.slax

    EVENTD_EVENT_SEND_FAILED

    Junos OS processes can request that the event processing process (eventd) notify them when a specific event occurs. eventd could not send an event notification for the indicated reason.

    EVENTD_FORK_ERR.slax

    EVENTD_FORK_ERR

    The event processing process (eventd) could not create a child process for executing policies.

    EVENTD_PIPE_ERR.slax

    EVENTD_PIPE_ERR

    The event processing process (eventd) could not create a pipe for interprocess communication.

    EVENTD_VERSION_MISMATCH.slax

    EVENTD_VERSION_MISMATCH

    The event processing process (eventd) received an event with the indicated version indicator, which does not match the indicated version expected by eventd.

    FPCLOGIN_IP_ADDRESS_GET_FAILURE.slax

    FPCLOGIN_IP_ADDRESS_GET_FAILURE

    The fpclogin module attempted to get the IP address of the physical interface module. The attempt failed.

    FSAD_ERROR.slax

    FSAD_ERROR

    Internal error message of the file system access process (fsad)

    FUD_MEMORY_ALLOCATION_FAILURE.slax

    FUD_MEMORY_ALLOCATION_FAILURE

    The UDP forwarding process (fud) could not allocate the indicated amount of memory from the heap.

    FUD_RTSOCK_WRITE_FAILURE.slax

    FUD_RTSOCK_WRITE_FAILURE

    The UDP forwarding process (fud) could not write to its routing socket for the indicated reason.

    FUD_SENDMSG_FAILURE.slax

    FUD_SENDMSG_FAILURE

    The UDP forwarding process (fud) could not send data to the indicated destination port and address using the indicated interface and routing instance, which it needs to do during normal operation.

    FUD_SENDMSG_NOINT_FAILURE.slax

    FUD_SENDMSG_NOINT_FAILURE

    The UDP forwarding process (fud) could not send data to the indicated destination port and address using the indicated routing instance, which it needs to do during normal operation.

    FUD_SETSOCKOPT_FAILURE.slax

    FUD_SETSOCKOPT_FAILURE

    The UDP forwarding process (fud) could not set the indicated socket option.

    FUD_SOCKET_FAILURE.slax

    FUD_SOCKET_FAILURE

    The UDP forwarding process (fud) could not create a socket.

    GGSN_ALARM_TRAP_SEND.slax

    GGSN_ALARM_TRAP_SEND

    An alarm trap to be relayed by the services PICs process (serviced) failed to initialize.

    GGSN_TRAP_SEND.slax

    GGSN_TRAP_SEND

    The system sent a GGSN trap of an unrecognized type.

    GRAPH_NO_MEMORY.slax

    GRAPH_NO_MEMORY

    The graphing process could not allocate memory while trying to create a graph.

    HNCACHED_PATRICIA_ERROR.slax

    HNCACHED_PATRICIA_ERROR

    This event is generated when a call to a Patricia tree library function returns an error.

    ICCPD_ASSERT_SOFT.slax

    ICCPD_ASSERT_SOFT

    The source code for the interchassis communication process (iccpd) includes internal self-consistency checks. As iccpd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. iccpd created a diagnostic core file for analysis by technical support personnel and continued to run.

    ICCPD_OPEN_ERROR.slax

    ICCPD_OPEN_ERROR

    The interchassis communication process (iccpd) could not initialize.

    IDP_DAEMON_INIT_FAILED.slax

    IDP_DAEMON_INIT_FAILED

    An attempt to start the IDP policy daemon failed because an error was encountered during initialization.

    IDP_INTERNAL_ERROR.slax

    IDP_INTERNAL_ERROR

    This event is generated when the IDP daemon encounters an internal error.

    IKED_CFG_PATRICIA_ERROR.slax

    IKED_CFG_PATRICIA_ERROR

    This event is generated when a call to a Patricia tree library function returns an error.

    JCS_BBD_LOAD_FAILURE.slax

    JCS_BBD_LOAD_FAILURE

    The JCS process (jcsd) could not load blade bay data for the specified blade.

    JCS_BBD_LOCAL_MISMATCH.slax

    JCS_BBD_LOCAL_MISMATCH

    The blade bay data retrieved for the specified blade does not match the data loaded during the reboot process. This error usually indicates that blade bay data in the JCS Management Module was changed since the last reboot.

    JCS_BBD_NOT_FOUND.slax

    JCS_BBD_NOT_FOUND

    This event is generated when the blade bay data is not found for the specified blade.

    JCS_BBD_NOT_VALID.slax

    JCS_BBD_NOT_VALID

    This event is generated when the blade bay data for the specified blade is invalid.

    JCS_BBD_PARSE_ERROR.slax

    JCS_BBD_PARSE_ERROR

    This event is generated when the blade bay data for the specified blade did not parse correctly.

    JCS_BBD_PEER_MISMATCH.slax

    JCS_BBD_PEER_MISMATCH

    The blade bay data retrieved for the specified peer blade does not match the data retrieved for the local blade. This error indicates that blade bay data in the JCS Management Module was not configured properly.

    JCS_KERNEL_RSD_LINK_DOWN.slax

    JCS_KERNEL_RSD_LINK_DOWN

    The JCS process (jcsd) has disabled kernel RSD communication for the specified reason.

    JCS_MM_COMMUNICATION_ERROR.slax

    JCS_MM_COMMUNICATION_ERROR

    The JCS process (jcsd) could not send an SNMP request to the Management Module because of the indicated error.

    JCS_READ_BANDWIDTH_ERROR.slax

    JCS_READ_BANDWIDTH_ERROR

    The indicated error occurred when attempting to read the current switch bandwidth.

    JCS_READ_BBD_ERROR.slax

    JCS_READ_BBD_ERROR

    The indicated error occurred when attempting to read the current blade bay data by using a sysctl call.

    JCS_SWITCH_COMMUNICATION_ERROR.slax

    JCS_SWITCH_COMMUNICATION_ERROR

    The JCS process (jcsd) could not send an SNMP request to the indicated Switch Module because of the indicated error.

    JSRPD_DAEMONIZE_FAILED.slax

    JSRPD_DAEMONIZE_FAILED

    The Juniper Services Redundancy Protocol process (jsrpd) could not create a version of itself to run in the background as a daemon.

    JSRPD_EVLIB_EXIT_FAILURE.slax

    JSRPD_EVLIB_EXIT_FAILURE

    The Juniper Services Redundancy Protocol process (jsrpd) returned from an event loop, which it should never do.

    JSRPD_RG_STATE_CHANGE.slax

    JSRPD_RG_STATE_CHANGE

    The Juniper Services Redundancy Protocol process (JSRPD) detected an event that caused the state of the chassis cluster redundancy group to change due to the reason indicated in the log.

    JSRPD_SET_SPU_MON_FAILURE.slax

    JSRPD_SET_SPU_MON_FAILURE

    The Juniper Services Redundancy Protocol process (JSRPD) detected Services Processing Unit (SPU) monitoring failure for a redundancy group.

    JSRPD_SOCKET_CREATION_FAILURE.slax

    JSRPD_SOCKET_CREATION_FAILURE

    The Juniper Services Redundancy Protocol process (jsrpd) could not successfully create a socket.

    JSRPD_SOCKET_LISTEN_FAILURE.slax

    JSRPD_SOCKET_LISTEN_FAILURE

    The Juniper Services Redundancy Protocol process (jsrpd) could not successfully listen on a socket.

    JSRPD_SOCKET_RECV_HB_FAILURE.slax

    JSRPD_SOCKET_RECV_HB_FAILURE

    The Juniper Services Redundancy Protocol process (jsrpd) was not successfully received on a socket.

    KMD_SNMP_PIC_NO_RESPONSE.slax

    KMD_SNMP_PIC_NO_RESPONSE

    The indicated PIC did not respond to a request from the key management process (kmd) for SNMP statistics about IP Security (IPsec) associations.

    L2ALD_IPC_PIPE_WRITE_ERROR.slax

    L2ALD_IPC_PIPE_WRITE_ERROR

    The Layer 2 address learning process (l2ald) could not write to an interprocess communication (IPC) pipe for the indicated reason.

    L2ALD_PIP_IFD_READ_RETRY.slax

    L2ALD_PIP_IFD_READ_RETRY

    The Layer 2 address learning process (l2ald) could not read the provide-in-provider interface (pip0) from the kernel.

    L2CPD_ABORT.slax

    L2CPD_ABORT

    The Layer 2 Control Protocol process (l2cpd) terminated because of an internal error.

    L2CPD_ASSERT.slax

    L2CPD_ASSERT

    The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. l2cpd with the indicated executable name and process ID (PID) terminated because the indicated test failed at the indicated line number in the indicated source file. The process created a diagnostic core file for analysis by technical support personnel.

    L2CPD_ASSERT_SOFT.slax

    L2CPD_ASSERT_SOFT

    The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. l2cpd with the indicated executable name and process ID (PID) terminated because the indicated type of check failed at the indicated line number in the indicated source file. The process continued to run, but created a diagnostic core file for analysis by technical support personnel.

    L2CPD_PPM_WRITE_ERROR.slax

    L2CPD_PPM_WRITE_ERROR

    The Layer 2 Control Protocol process (l2cpd) could not write a message on the pipe to the periodic packet management process (ppmd).

    L2CPD_SCHED_SLIP.slax

    L2CPD_SCHED_SLIP

    The Layer 2 Control Protocol process (l2cpd) delayed an event, such as issuing an adjacency establishment message that was supposed to occur at a particular time. The event did not occur at the right time.

    L2CPD_SYSTEM_CALL_FAILED.slax

    L2CPD_SYSTEM_CALL_FAILED

    A system call made by the Layer 2 Control Protocol process (l2cpd) failed.

    L2TPD_EVLIB_CREATE_FAILED.slax

    L2TPD_EVLIB_CREATE_FAILED

    The Layer 2 Tunneling Protocol process (l2tpd) could not create a context for handling asynchronous events.

    L2TPD_SERVER_START_FAILED.slax

    L2TPD_SERVER_START_FAILED

    The Layer 2 Tunneling Protocol (L2TP) server did not start.

    LACPD_DAEMONIZE_FAILED.slax

    LACPD_DAEMONIZE_FAILED

    The Link Aggregation Control Protocol process (lacpd) could not create a version of itself to run in the background as a daemon.

    LIBESPTASK_SNMP_CONN_PROG.slax

    LIBESPTASK_SNMP_CONN_PROG

    The indicated error occurred while the process using libesptask was connecting to the SNMP master agent.

    LIBESPTASK_SNMP_SOCKOPT_RECVBUF.slax

    LIBESPTASK_SNMP_SOCKOPT_RECVBUF

    The process using libesptask could not set the size of the kernel receive buffer, which allows it to accept the largest possible packet from the SNMP primary agent.

    LIBESPTASK_SNMP_SOCKOPT_SENDBUF.slax

    LIBESPTASK_SNMP_SOCKOPT_SENDBUF

    The process using libesptask could not set the size of the kernel send buffer, which allows it to send the largest possible packet to the SNMP primary agent.

    LIBJNX_DEFAULT_IP_ADDR_NOT_SET.slax

    LIBJNX_DEFAULT_IP_ADDR_NOT_SET

    A Junos OS process could not retrieve the system default IP address from the kernel because the address is not defined there.

    LIBJNX_EVLIB_FAILURE.slax

    LIBJNX_EVLIB_FAILURE

    A Junos OS process called the indicated function in the event library. The function failed for the indicated reason.

    LIBJNX_EXEC_SIGNALED.slax

    LIBJNX_EXEC_SIGNALED

    A Junos OS process created a child process to execute the indicated command. The child process received the indicated signal and exited.

    LIBJNX_REPLICATE_RCP_ERROR.slax

    LIBJNX_REPLICATE_RCP_ERROR

    This event is generated when the rcp command fails during replication.

    LIBJNX_SNMP_ENGINE_FILE_FAILURE.slax

    LIBJNX_SNMP_ENGINE_FILE_FAILURE

    A Junos OS process could not perform the indicated operation on the indicated SNMP engine data file.

    LIBJNX_SNMP_ENGINE_SCAN_FAILURE.slax

    LIBJNX_SNMP_ENGINE_SCAN_FAILURE

    A Junos OS process could not perform the scan operation on the indicated SNMP engine data file.

    LIBJNX_SOCKET_FAILURE.slax

    LIBJNX_SOCKET_FAILURE

    Various system processes use TCP, UDP, and Reliable Data Protocol (RDP) sockets. The indicated socket operation failed for the indicated reason.

    LIBJSNMP_NS_LOG_EMERG.slax

    LIBJSNMP_NS_LOG_EMERG

    This event is generated when there are SNMP errors with LOG_EMERG as severity.

    LIBJSNMP_NS_LOG_ERR.slax

    LIBJSNMP_NS_LOG_ERR

    This event is generated when there are SNMP errors with LOG_ERR as severity.

    LIBMSPRPC_CLIENT_INIT_FAILED.slax

    LIBMSPRPC_CLIENT_INIT_FAILED

    A Junos OS process (mspinfo) could not establish initialization of the RPC client.

    LIBMSPRPC_CLIENT_KCOM_FAILED.slax

    LIBMSPRPC_CLIENT_KCOM_FAILED

    A Junos OS process (mspinfo) could not establish initialization of the KCOM subsystem.

    LIBMSPRPC_CLIENT_KCOM_NO_IF.slax

    LIBMSPRPC_CLIENT_KCOM_NO_IF

    A Junos OS process (mspinfo) could not find any configured and active extension-provider interfaces.

    LIBMSPRPC_CLIENT_NO_CONNECTION.slax

    LIBMSPRPC_CLIENT_NO_CONNECTION

    Remote execution of the command given from the Routing Engine to the PIC failed. The Routing Engine cannot connect to the PIC.

    LIBMSPRPC_CLIENT_NO_REPLY.slax

    LIBMSPRPC_CLIENT_NO_REPLY

    Remote execution of the command given from the Routing Engine to the PIC failed. There was no reply from the PIC.

    LIBMSPRPC_CLIENT_PIC_DOWN.slax

    LIBMSPRPC_CLIENT_PIC_DOWN

    Remote execution of the command given from the Routing Engine to the PIC failed. The PIC is down.

    LIBMSPRPC_CLIENT_WRONG_OUTPUT.slax

    LIBMSPRPC_CLIENT_WRONG_OUTPUT

    Remote execution of the command given from the Routing Engine to the PIC failed. The PIC returned unexpected output.

    LIBSERVICED_CLIENT_CONNECTION.slax

    LIBSERVICED_CLIENT_CONNECTION

    An attempt to establish a client connection failed.

    LIBSERVICED_SOCKET_BIND.slax

    LIBSERVICED_SOCKET_BIND

    This event is generated when an attempt to bind a server socket for receiving client requests failed.

    LIBSERVICED_SOCKET_PRIVATIZE.slax

    LIBSERVICED_SOCKET_PRIVATIZE

    An attempt to attach a socket to the management routing instance for communication between the Routing Engine and GGSN-C PICs failed.

    LICENSE_EXPIRED.slax

    LICENSE_EXPIRED

    A time-based license for a feature has expired. The feature will remain inactive until a new license is installed.

    LICENSE_GRACE_PERIOD_APPROACHING.slax

    LICENSE_GRACE_PERIOD_APPROACHING

    The grace period for a licensable feature is about to expire. Unless a new license is installed, the feature will become inactive after the grace period expires.

    LICENSE_GRACE_PERIOD_EXCEEDED.slax

    LICENSE_GRACE_PERIOD_EXCEEDED

    The grace period for a scale license is about to expire. Unless the scale license is upgraded, the license will scale back to the licensed limit after the grace period expires.

    LICENSE_GRACE_PERIOD_EXPIRED.slax

    LICENSE_GRACE_PERIOD_EXPIRED

    The grace period for a licensable feature has expired. Strict license enforcement will remain active until a new license is installed.

    LICENSE_NEARING_EXPIRY.slax

    LICENSE_NEARING_EXPIRY

    A time-based license for a feature is about to expire. Unless a new license is installed, the feature will become inactive after the license expires.

    LICENSE_SOCKET_FAILURE.slax

    LICENSE_SOCKET_FAILURE

    This event is generated when the indicated process encounters a system error while manipulating a socket.

    LLDPD_SYSTEM.slax

    LLDPD_SYSTEM

    This event is generated when a system call made by the Link Layer Discovery Protocol process (LLDPD) fails.

    LPDFD_DYN_PDB_OPEN_FAILED.slax

    LPDFD_DYN_PDB_OPEN_FAILED

    The local policy decision function process (lpdfd) fails to open the profile database.

    LPDFD_DYN_REGISTER_FAILED.slax

    LPDFD_DYN_REGISTER_FAILED

    The local policy decision function process (lpdfd) fails to register with the dynamic configuration subsystem.

    LPDFD_DYN_SDB_OPEN_FAILED.slax

    LPDFD_DYN_SDB_OPEN_FAILED

    The local policy decision function process (lpdfd) fails to open the session database.

    LPDFD_PCONN_SERVER.slax

    LPDFD_PCONN_SERVER

    The local policy decision function process (lpdfd) pconn server fails to initialize.

    LPDFD_RTSOCK_OPEN_FAILURE.slax

    LPDFD_RTSOCK_OPEN_FAILURE

    The local policy decision function (LPDF) services process could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error.

    MIB2D_REALPATH_FAILURE.slax

    MIB2D_REALPATH_FAILURE

    When MIB2D is copying the /var/db/dcd.snmp_ix file, it could not resolve its real path.

    MIB2D_RTSLIB_READ_FAILURE.slax

    MIB2D_RTSLIB_READ_FAILURE

    A call to the indicated function in the routing socket library failed during the indicated operation on the indicated object.

    MIB2D_SNMP_INDEX_ASSIGN.slax

    MIB2D_SNMP_INDEX_ASSIGN

    This event is generated when MIB2D cannot assign an SNMP index for each interface.

    MIB2D_SNMP_INDEX_DUPLICATE.slax

    MIB2D_SNMP_INDEX_DUPLICATE

    This event is generated when the first interface name was assigned the same SNMP index as the second interface name.

    MIB2D_SNMP_INDEX_UPDATE_STAT.slax

    MIB2D_SNMP_INDEX_UPDATE_STAT

    This event is generated when MIB2D cannot get the status of the SNMP index file.

    MIB2D_SNMP_INDEX_WRITE.slax

    MIB2D_SNMP_INDEX_WRITE

    This event is generated when MIB2D cannot write to a file containing all the indices.

    NSD_MEMORY_ALLOC_FAILED.slax

    NSD_MEMORY_ALLOC_FAILED

    This event is generated when the network security process (nsd) could not allocate the indicated number of bytes of memory.

    NSD_SEC_NODE_COMP_SYNC_FAILED.slax

    NSD_SEC_NODE_COMP_SYNC_FAILED

    One or more subcomponents of the network security process (nsd) failed to synchronize their state when the nsd restarted on secondary mode.

    NSTRACED_MEMORY_ALLOC_FAILED.slax

    NSTRACED_MEMORY_ALLOC_FAILED

    The USP trace process (nstraced) could not allocate the indicated number of bytes of memory.

    NSTRACED_SSAMLIB_CALL_FAILED.slax

    NSTRACED_SSAMLIB_CALL_FAILED

    The indicated error occurred when the usp trace daemon process (nstraced) called a function in the ssamlib library or tried to process a callback from the library.

    PFE_NH_RESOLVE_THROTTLED.slax

    PFE_NH_RESOLVE_THROTTLED

    The Packet Forwarding Engine throttled next-hop resolution requests from the indicated interface because the high number of requests might constitute an attempted denial-of-service (DoS) attack. Examples of events that generate next-hop resolution requests include an attempt to forward a packet without an Address Resolution Protocol (ARP) entry and receiving a multicast data packet with no matching route. Normally, the Packet Forwarding Engine forwards the requests to the Routing Engine.

    PPMD_ASSERT_SOFT.slax

    PPMD_ASSERT_SOFT

    The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As ppmd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. ppmd created a diagnostic core file for analysis by technical support personnel and continued to run.

    PPMD_READ_ERROR.slax

    PPMD_READ_ERROR

    The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As ppmd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. ppmd created a diagnostic core file for analysis by technical support personnel and continued to run.

    RDD_EVLIB_CREATE_FAILURE.slax

    RDD_EVLIB_CREATE_FAILURE

    The redundant interfaces process (rdd) could not create a context used for handling all asynchronous events (such as timers and message availability).

    RPD_ABORT.slax

    RPD_ABORT

    The routing protocol process (rpd) terminated because of an internal error.

    RPD_ACTIVE_TERMINATE.slax

    RPD_ACTIVE_TERMINATE

    After receiving multiple termination requests, the routing protocol process (rpd) exited without performing the indicated cleanup tasks.

    RPD_ASSERT.slax

    RPD_ASSERT

    The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, causing the instance of rpd that was using the indicated binary and had the indicated process ID (PID) to terminate. The process created a diagnostic core file for analysis by technical support personnel.

    RPD_ASSERT_SOFT.slax

    RPD_ASSERT_SOFT

    The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, but the instance of rpd that was using the indicated binary and had the indicated process ID (PID) continued running. The process created a diagnostic core file for analysis by technical support personnel.

    RPD_DYN_CFG_BAD_REQ_OPCODE.slax

    RPD_DYN_CFG_BAD_REQ_OPCODE

    The routing protocol process (rpd) received a dynamic configuration request with an unexpected operation code.

    RPD_DYN_CFG_BUSY_SIGNAL_FAILED.slax

    RPD_DYN_CFG_BUSY_SIGNAL_FAILED

    The routing protocol process (rpd) failed to notify dynamic configuration clients about its availability to process dynamic configuration requests.

    RPD_DYN_CFG_GET_PROF_NAME_FAILED.slax

    RPD_DYN_CFG_GET_PROF_NAME_FAILED

    The routing protocol process (rpd) tried to get the profile name from the session snapshot and failed.

    RPD_DYN_CFG_GET_PROFILE_FAILED.slax

    RPD_DYN_CFG_GET_PROFILE_FAILED

    The routing protocol process (rpd) tried to load a profile from the database and failed.

    RPD_DYN_CFG_GET_SES_STATE_FAILED.slax

    RPD_DYN_CFG_GET_SES_STATE_FAILED

    The routing protocol process (rpd) failed to get the session state from the session snapshot.

    RPD_DYN_CFG_GET_SNAPSHOT_FAILED.slax

    RPD_DYN_CFG_GET_SNAPSHOT_FAILED

    The routing protocol process (rpd) tried to load client session data from the database and failed.

    RPD_DYN_CFG_PDB_CLOSE_FAILED.slax

    RPD_DYN_CFG_PDB_CLOSE_FAILED

    The routing protocol process (rpd) tried to close the profile database and failed.

    RPD_DYN_CFG_PDB_OPEN_FAILED.slax

    RPD_DYN_CFG_PDB_OPEN_FAILED

    The routing protocol process (rpd) tried to open the profile database and failed.

    RPD_DYN_CFG_PROCESSING_FAILED.slax

    RPD_DYN_CFG_PROCESSING_FAILED

    The routing protocol process (rpd) tried to process dynamic configuration and failed.

    RPD_DYN_CFG_REGISTER_FAILED.slax

    RPD_DYN_CFG_REGISTER_FAILED

    The routing protocol process (rpd) tried to register with the dynamic configuration subsystem and failed.

    RPD_DYN_CFG_REQUEST_ACK_FAILED.slax

    RPD_DYN_CFG_REQUEST_ACK_FAILED

    The routing protocol process (rpd) tried to acknowledge a dynamic configuration request and failed.

    RPD_DYN_CFG_SCHEMA_OPEN_FAILED.slax

    RPD_DYN_CFG_SCHEMA_OPEN_FAILED

    The routing protocol process (rpd) tried to open the configuration schema and failed.

    RPD_DYN_CFG_SDB_CLOSE_FAILED.slax

    RPD_DYN_CFG_SDB_CLOSE_FAILED

    The routing protocol process (rpd) tried to close the session database and failed.

    RPD_DYN_CFG_SDB_OPEN_FAILED.slax

    RPD_DYN_CFG_SDB_OPEN_FAILED

    The routing protocol process (rpd) tried to open the session database and failed.

    RPD_DYN_CFG_SES_RECOVERY_FAILED.slax

    RPD_DYN_CFG_SES_RECOVERY_FAILED

    The routing protocol process (rpd) tried to recover a session and failed.

    RPD_ISIS_LSPCKSUM.slax

    RPD_ISIS_LSPCKSUM

    The indicated IS-IS informational link-state PDU (LSP) failed an internal checksum validity test, indicating that it was corrupted.

    RPD_ISIS_OVERLOAD.slax

    RPD_ISIS_OVERLOAD

    The IS-IS link-state database is full and no additional memory can be allocated for it.

    RPD_KRT_KERNEL_BAD_ROUTE.slax

    RPD_KRT_KERNEL_BAD_ROUTE

    As it restarted, the routing protocol process (rpd) could not process a route obtained from the kernel because the route contained references to objects that are no longer valid.

    RPD_KRT_Q_RETRIES.slax

    RPD_KRT_Q_RETRIES

    The routing protocol process (rpd) attempted to update the kernel for the indicated times and failed. It will continue retrying.

    RPD_LMP_UNEXPECTED_OPCODE.slax

    RPD_LMP_UNEXPECTED_OPCODE

    The routing protocol process (rpd) received the indicated type of message, which had the indicated invalid operation code.

    RPD_OS_MEMHIGH.slax

    RPD_OS_MEMHIGH

    The routing protocol process (rpd) is using the indicated amount and percentage of Routing Engine memory, which is considered excessive.

    RPD_RT_ERROR.slax

    RPD_RT_ERROR

    A route in the routing table was found to be in an unrecoverable error state.

    RPD_TASK_FORK.slax

    RPD_TASK_FORK

    The routing protocol process failed to create the indicated child process.

    RT_SCREEN_TCP.slax

    RT_SCREEN_TCP

    A TCP attack category.

    RT_SCREEN_UDP.slax

    RT_SCREEN_UDP

    A UDP attack category.

    RTLOGD_DAEMONIZE_FAILED.slax

    RTLOGD_DAEMONIZE_FAILED

    The JSR log daemon could not create a version of itself to run in the background as a daemon.

    RTLOGD_EVLIB_FAILURE.slax

    RTLOGD_EVLIB_FAILURE

    The JSR log daemon called the indicated event library function. The function failed with the indicated error.

    RTLOGD_GET_TNP_ADDRESS_FAILED.slax

    RTLOGD_GET_TNP_ADDRESS_FAILED

    The JSR log daemon failed to determine the local TNP address used to receive JSR log.

    RTLOGD_LOG_BIND_ERROR.slax

    RTLOGD_LOG_BIND_ERROR

    The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to connect to the forwarder.

    RTLOGD_LOG_READ_ENABLE_ERROR.slax

    RTLOGD_LOG_READ_ENABLE_ERROR

    The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to enable the reading of the JSR log from the forwarder.

    RTLOGD_LOG_READ_ERROR.slax

    RTLOGD_LOG_READ_ERROR

    The JSR log daemon relayed the JSR logs from the dataplane to the system event daemon for logging. The JSR log daemon failed to read JSR logs for the indicated reason.

    RTPERF_CPU_THRESHOLD_EXCEEDED.slax

    RTPERF_CPU_THRESHOLD_EXCEEDED

    The Packet Forwarding Engine CPU threshold has been exceeded.

    SAVAL_RTSOCK_FAILURE.slax

    SAVAL_RTSOCK_FAILURE

    The MAC SA Validate system process (jsavald) experienced the indicated error with a routing socket.

    SDXD_DAEMONIZE_FAIL.slax

    SDXD_DAEMONIZE_FAIL

    The service deployment system process (sdxd) could not create a version of itself to run in the background as a daemon.

    SERVICED_CLIENT_DISCONNECTED.slax

    SERVICED_CLIENT_DISCONNECTED

    The remote client closed the connection or stopped responding.

    SERVICED_CLIENT_ERROR.slax

    SERVICED_CLIENT_ERROR

    An I/O error caused the termination of a connection with an interface client.

    SERVICED_COMMAND_FAILED.slax

    SERVICED_COMMAND_FAILED

    An error caused a command being executed on an interface client to be canceled.

    SERVICED_CONNECTION_ERROR.slax

    SERVICED_CONNECTION_ERROR

    The remote client closed the connection when data was expected.

    SERVICED_EVENT_FAILED.slax

    SERVICED_EVENT_FAILED

    The Services PICs process (serviced) could not continue processing a task because a call to a function in the event library failed.

    SERVICED_INIT_FAILED.slax

    SERVICED_INIT_FAILED

    One of the steps in the initialization sequence for the Services PICs process (serviced) failed.

    SERVICED_INTERNAL_INCONSISTENCY.slax

    SERVICED_INTERNAL_INCONSISTENCY

    An internal consistency check failed due to a mismatch between expected and received values for the specified object.

    SERVICED_MALLOC_FAILURE.slax

    SERVICED_MALLOC_FAILURE

    The services PICs process (serviced) could not allocate the number of bytes needed to hold the indicated object.

    SERVICED_NETWORK_FAILURE.slax

    SERVICED_NETWORK_FAILURE

    An attempt to use the indicated network library call failed with an error.

    SERVICED_PID_FILE_LOCK.slax

    SERVICED_PID_FILE_LOCK

    As part of normal startup, the services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not lock the file.

    SERVICED_PID_FILE_UPDATE.slax

    SERVICED_PID_FILE_UPDATE

    As part of normal startup, the services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not write to the file.

    SERVICED_RTSOCK_SEQUENCE.slax

    SERVICED_RTSOCK_SEQUENCE

    The services PICs process (serviced) encountered a sequence error while receiving messages from the routing socket library.

    SERVICED_SIGNAL_HANDLER.slax

    SERVICED_SIGNAL_HANDLER

    As a part of normal functioning, the services PICs process (serviced) attempted to initialize a signal-handling function. Part of the initialization failed with an error.

    SERVICED_SOCKET_CREATE.slax

    SERVICED_SOCKET_CREATE

    An attempt by the services PICs process (serviced) to create a new socket for communication with an interface client failed with an error.

    SERVICED_SOCKET_IO.slax

    SERVICED_SOCKET_IO

    A call to a socket library function indicated that an error occurred while attempting to perform I/O.

    SERVICED_SOCKET_OPTION.slax

    SERVICED_SOCKET_OPTION

    An attempt to set an option on a socket failed

    SERVICED_STDLIB_FAILURE.slax

    SERVICED_STDLIB_FAILURE

    The value returned by a call to a library function indicated that an error occurred.

    SIB_CHECK.slax

    SIB_CHECK

    SNMP_PATRICIA_ERROR.slax

    SNMP_PATRICIA_ERROR

    A call to a Patricia tree library function returns an error.

    SNMP_RTSLIB_FAILURE.slax

    SNMP_RTSLIB_FAILURE

    A call to the indicated function in the routing socket library failed with the indicated error.

    SNMPD_FILE_FAILURE.slax

    SNMPD_FILE_FAILURE

    The SNMP agent process (snmpd) could not access the indicated file.

    SNMPD_RMONFILE_FAILURE.slax

    SNMPD_RMONFILE_FAILURE

    The indicated operation failed on the indicated remote monitoring (RMON) data file.

    SNMPD_SEND_FAILURE.slax

    SNMPD_SEND_FAILURE

    The SNMP agent process (snmpd) could not send either a protocol data unit (PDU) to the UDP or a message to a subagent.

    SNMPD_SOCKET_FATAL_FAILURE.slax

    SNMPD_SOCKET_FATAL_FAILURE

    The SNMP agent process (snmpd) uses sockets for communication with subagents. The process exited after a socket operation, such as creation or removal, failed.

    SNMPD_SUBAGENT_NO_RESOURCES.slax

    SNMPD_SUBAGENT_NO_RESOURCES

    The SNMP agent process (snmpd) uses certain resources for communication with subagents. However, the resources were not available for communication with the indicated subagent.

    SPD_DAEMONIZE_FAILED.slax

    SPD_DAEMONIZE_FAILED

    The adaptive services process (spd) could not create a version of itself to run in the background as a daemon.

    SPD_EVLIB_CREATE_FAILURE.slax

    SPD_EVLIB_CREATE_FAILURE

    The adaptive services process (spd) could not create a context used for handling all asynchronous events (such as timers and message availability).

    SPD_GEN_NUM_FAIL.slax

    SPD_GEN_NUM_FAIL

    The adaptive services process (spd) attempted to initialize the generation-number for the service sets. However, the memory allocation failed.

    TASK_OS_MEMHIGH.slax

    TASK_OS_MEMHIGH

    The process is using the indicated amount and percentage of Routing Engine memory, which is considered excessive.

    TASK_SYSTEM.slax

    TASK_SYSTEM

    A system call made by this process failed.

    TFTPD_RECVCOMPLETE_INFO.slax

    TFTPD_RECVCOMPLETE_INFO

    The TFTP process (tnp.tftpd) received the last portion of a transmitted file. This message records the number of blocks received, the block size used, and the name of the file to which the data was written.

    UI_CHILD_SIGNALED.slax

    UI_CHILD_SIGNALED

    The child process (PID) created by the management process (mgd) to execute a command for it exited with the following core dump message: “Child received signal: PID 17332, signal Abort trap: 6, core dumped, command='/proc/1533/file”

    UI_CMDLINE_READ_LINE.slax

    UI_CMDLINE_READ_LINE

    This message indicates that the management process (mgd) has received a command from the user.

    UI_DBASE_REBUILD_FAILED.slax

    UI_DBASE_REBUILD_FAILED

    The management process (mgd) could not rebuild the configuration database file.

    UI_DBASE_REBUILD_SCHEMA_FAILED.slax

    UI_DBASE_REBUILD_SCHEMA_FAILED

    The management process (mgd) could not rebuild the schema for the configuration database.

    UI_DBASE_REOPEN_FAILED.slax

    UI_DBASE_REOPEN_FAILED

    After rebuilding the schema file for the configuration database, the management process (mgd) closes the file and reopens it in read-only mode to prevent corruption. It could not reopen the file.

    UI_NETCONF_CMD.slax

    UI_NETCONF_CMD

    This message indicates that the user executed a command by using the NETCONF application programming interface (API).

    UI_SCHEMA_SEQUENCE_ERROR.slax

    UI_SCHEMA_SEQUENCE_ERROR

    The Junos OS user interface schema file records all CLI commands and configuration statements available in the Junos operating system. The management process (mgd) rebuilds the schema as necessary to be compatible with the Junos OS software installed on the device. A sequence number in the schema acts as a checksum that represents its content and format. A Junos OS process attempted to access the schema but determined that the schema's sequence number means that it is incompatible with the process.

    UTMD_MALLOC_FAILURE.slax

    UTMD_MALLOC_FAILURE

    The example process (utmd) could not allocate memory for a resource, possibly due to lack of memory.

    UTMD_SSAMLIB_FAILURE.slax

    UTMD_SSAMLIB_FAILURE

    The example process (utmd) encountered an error while calling a function or from a callback of ssamlib.

    VCCPD_PROTOCOL_LSPCKSUM.slax

    VCCPD_PROTOCOL_LSPCKSUM

    The indicated vccpd link-state PDU (LSP) failed an internal checksum validity test, implying that it was corrupted.

    VCCPD_PROTOCOL_OVERLOAD.slax

    VCCPD_PROTOCOL_OVERLOAD

    The vccpd link-state database is full and no additional memory can be allocated for it.

    VRRPD_MISSING_VIP.slax

    VRRPD_MISSING_VIP

    The indicated interface received a Virtual Router Redundancy Protocol (VRRP) packet for the indicated VRRP group in which the indicated virtual IP address was missing.

    WEB_ALLOCATE.slax

    WEB_ALLOCATE

    The Web management process (httpd) could not allocate the indicated amount of memory, for the indicated reason.

    WEB_MEMORY_ALLOC.slax

    WEB_MEMORY_ALLOC

    The Web management process (httpd) could not allocate the indicated number of bytes of memory, for the indicated reason.

    WEB_MGD_LISTEN_ERROR.slax

    WEB_MGD_LISTEN_ERROR

    The Web management process (httpd) could not open the mgd listening socket.

    WEB_SOCKET.slax

    WEB_SOCKET

    The Web management process (httpd) could not create a socket, for the indicated reason.

    WEBFILTER_CACHE_NOT_ENABLED.slax

    WEBFILTER_CACHE_NOT_ENABLED

    This event occurs whenever the webfilter (integrated web filtering) process failed to enable the web-filtering category cache.

    WEBFILTER_REQUEST_NOT_CHECKED.slax

    WEBFILTER_REQUEST_NOT_CHECKED

    The Web filtering failed to check a Web request.

    Unstructured Events

    Table 2 lists the event policies for unstructured Junos OS log messages.

    Table 2: Unstructured Events Detected by AI-Scripts

    Event Policy File Name

    Event Matching Pattern Used for the Service Now Event Synopsis

    Description

    problem-event-acb_storm_active.slax

    SYSTEM:fpm_atlas_acb_storm_state_change: acb storm active

    The "acb storm active" message is logged when a Control Board has received too many interrupts to process in a second.

    problem-event-ASICiniterror.slax

    PFE: ASIC Initialization Error

    Any Packet Forwarding Engine ASIC initialization error that occurs in conjunction with a system exception message, such as: router-name fpc5 CMG: Fatal ASIC initialization error, Offlining FPC

    problem-event-cannotperformaddandget.slax

    SYSTEM:cannot perform nh operation ADDANDGET

    When exporting local OSPF P2P LAN prefixes using rib groups, an error message can be logged containing the ADDANDGET keyword.

    problem-event-CB_alarm.slax

    SYSTEM:Alarm set: CB color=RED, class=CHASSIS, reason=CB

    The CB Failure message reports a hardware issue. Usually, this is with the referenced Control Board, although sometimes it may be with an FPC.

    problem-event-CCHIPabnormaldiscard.slax

    PFE:.*CCHIP: .*abnormal discard seen.*

    Packet Forwarding Engine board is reporting CCHIP abnormal discard errors.

    problem-event-CCHIPSRAMparityerror.slax

    PFE: SRAM Parity Error

    Any Packet Forwarding Engine SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name ssb CCHIP: %PFE-3: SRAM parity error 0x80000 bank 0x1

    problem-event-cellunderflow.slax

    PFE: XMCHIP[(].[)]: (%PFE-.*: )?FI: Cell underflow at the state stage

    The fabric cells are arriving late on the egress PFE.

    problem-event-clockerror.slax

    PFE:.*clock error.*

    Clock error reported on the Packet Forwarding Engine board.

    problem-event-cm_read_i2c.slax

    SYSTEM:.*cm_read_i2c errno is 5.*

    The chassis manager event message results from an error in calculating the DC power budget for Packet Ordering Engine (POE) interfaces.

    problem-event-cmalarm_major.slax

    CMALARM: Error (code: 1219, type:Major)

    There are some hardware errors in the PFE memory component

    problem-event-cmrfebhsl2error.slax

    PFE: CMRFEB: Fatal HSL2 errors for FPC

    A switching board (for example, FEB) is reporting a bad fabric connection to an FPC.

    problem-event-COSMAN-FPC.slax

    PFE:COSMAN-FPC PFE:COSMAN-FPC allocation of scheduler failed for stream type

    The COSMAN-FPC allocation failure event message is generated when a scheduler has to be allocated, but the action results in failure.

    problem-event-CRClinkerrordetected.slax

    PFE:.*CRC link error detected for FPC

    The high-speed link (HSL) messages show a cyclic redundancy check (CRC) error when sent between the switch fabric (SF) and Multi-Services Dense Port Concentrator (DPC).

    problem-event-cxge_spi42_update_errors.slax

    PFE:CXGE_SPI42: cxge_spi42_update_errors: snk: pkt end with eop abort

    2HX FPGA error The S2HX FPGA is reporting it received an invalid cell. This does not mean the chip caused the error, only that it is reporting it.

    problem-event-dcrash.slax

    Daemon crash

    A Junos OS daemon crash occurred with a core file.

    problem-event-DFPGA_errors.slax

    PFE:DFPGA got error events on non-zero link in last one second

    The "DFPGA got .* error events on non-zero link in last one second" message reports that the associated PIC has sent the stated number of spurious interrupts

    problem-event-DFWjtreecutoverfailed.slax

    PFE: DFW: jtree cutover failed

    The firewall filter configuration cannot be applied due to insufficient amount of contiguous memory on the SRAM.

    problem-event-dfwLogFirewallRows.slax

    PFE: mrvl_dfw_log_effuse_status:Firewall rows

    The TCAM error messages listed indicate a permanent nonfixable error with TCAM, if they persist after rebooting the EX Series switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are harmful. ACLs will be unreliable on this FPC.

    problem-event-ECCsinglebit.slax

    SYSTEM: Alarm set: .* color=RED, class=CHASSIS, reason=Host . ECC single bit parity error

    The Packet Forwarding Engine component is reporting that L2 Cache Single-bit ECC errors were detected in the last 30 seconds. If problem persists, this is likely to result in a component crash or failure.

    The "ECC single bit parity error" message reports that a correctable single bit error was detected once on the designated platform.

    problem-event-exceededRLIMITDATA.slax

    KERNEL:Process .* has exceeded 85% of RLIMIT_DATA

    This message indicates that the virtual memory size of a process’s data-segment area (RLIMIT_DATA) has exceeded its current soft limit.

    problem-event-EZsrhStruct_StatEntry_DoesExist.slax

    PFE:EZsrhStruct_StatEntry_DoesExist failed

    The message is emitted by the interface statistics module. The module is expecting a particular interface to be present and did not find the data structure for that interface.

    problem-event-Fabric_request_time_out.slax

    PFE:sntl_f_check_dest_errors: Fabric request time out for plane

    The "sntl_f_check_dest_errors: Fabric request time out for plane" message is logged when an issue with a fabric connection is detected. The message reports the hardware that detected the issue, not the hardware that produced it.

    problem-event-fast_failover_disabled.slax

    SYSTEM:cm_ff_ifd_disable: fast failover disabled

    The chassism process could not forward traffic as expected.

    problem-event-fatalerr.slax

    PFE:Fatal Error Encountered by .*

    The "Fatal Error Encountered by" message reports that the specified hardware is not able to handle some transit traffic internally.

    problem-event-Flow_table_full.slax

    SYSTEM: Alarm set: SESSION TABLE reason=CP/Flow session table full

    The "CP/Flow session table full" message indicates that the device has reached its maximum session capacity, causing the firewall to drop traffic.

    problem-event-FPC_alarm.slax

    Alarm set: FPC color=RED, class=CHASSIS, reason=FPC

    The FPC alarm error message reports that there is a hardware issue in the FPC

    problem-event-gen_auth_svc.slax

    KERNEL:general-authentication-service terminated by signal number 11

    The "general-authentication-service terminated" message reports that the authentication daemon has crashed and is being restarted. An associated core file has also been created on the device.

    problem-event-GenCfgBloberror.slax

    KERNEL:GENCFG: op 2 (Gencfg Blob) failed.*

    The kernel error message is generated because no handler exists for a certain GENCFG blob message.

    problem-event-harddiskerr.slax

    SYSTEM:Alarm set RE Host hard-disk drive error

    The hard-disk drive error message reports that a hard drive on the specified Routing Engine is no longer available to the kernel. Usually, either the message is reported from the backup Routing Engine or the master Routing Engine.

    If the message is reported to the master Routing Engine, the master Routing Engine gets the corrupted boot list, reboots to fix the error, and in the process Routing Engine mastership switches.

    If there is only one Routing Engine, the Routing Engine reboots on occurrence of this message. At that point the Routing Engine runs out of its alternate media, usually Compact Flash.

    problem-event-hsl2hsl2error.slax

    • PFE: HSL2: (%PFE-.*: )?HSL2 detected fatal error on

    FPC detected fatal HSL2 error.

    problem-event-HSR-crc-errors.slax

    PFE:HSR.Too many crc errors

    The "HSR: Too many crc errors" message reports that the indicated part in the message has gone into link error and may require reseating or replacement, or both. It may also indicate a false alarm thrown by the SIB orFPC.

    problem-event-i2c_fan_error.slax

    KERNEL.*i2c_s1.*group.*device

    Fan tray response error. This error due to the fan tray processing a different task.

    problem-event-ichipfcheck.slax

    PFE: .*ichip_f_check_dest_errors.*

    The FPC is reporting a bad fabric connection to one or more destinations. Another FPC is likely to be causing packet corruption.

    problem-event-ichippktdrop.slax

    PFE: Packet drop in Ichip

    The I-chip packet writer drop counter is incrementing, possibly indicating packet drops which may, but not necessarily, be due to a faulty switching board.

    problem-event-ichipregerr.slax

    PFE:ICHIP(.*)_REG_ERR:.*

    An ICHIP(.*)_REG_ERR message occurs when an I-chip reports an issue detected on an incoming fabric stream. The I-chip is only reporting the event, and is not the source of the fabric issue.

    problem-event-ichipstreamblk.slax

    CHIP_STREAM_BLOCKED: ICHIP (0) one or more stream blocked detected

    The message indicates an I-chip wedge condition in MX Series devices.

    problem-event-igmprelayfailed.slax

    SYSTEM:.*snp_igmp_io_flood: relay failed.*

    This message indicates that the device is flooding the IGMP unknown packet back on the same port that it was received on.

    problem-event-IMQ_error_sid.slax

    PFE:ICHIP IMQ: error sid detected

    The "error sid .* detected" message is reporting that the Packet Forwarding Engine is receiving instructions from the IMQ (Inbound Message Queuing) to forward data to a system identifier(SID) that is either a duplicate or that does not exist. The I-chip is only reporting the condition. It is not the cause of the issue.

    problem-event-ipv4_input_set_proto_and_ports.slax

    PFE: PPE PPE HW Fault Trap: (%PFE-.*: )? Count .*, PC .*, 0x.*: ipv4_input_set_proto_and_ports

    The ipv4_input_set_proto_and_ports message indicates that a trap occurred when the microcode attempted to interpret data past the end of the packet.

    problem-event-jbuserror.slax

    PFE: CMG: (%PFE-.*: )?Fatal JBUS error, chip

    An error occurred on the FPC control bus used for packet memory allocation.

    problem-event-jtreeLWMlimit.slax

    PFE:.*RSMON: Resource Category:jtree Instance.*less than LWM limit.*

    RSMON is reporting critical JTree memory resource shortage.

    problem-event-kernel_cksum.slax

    KERNEL:.*cksum.*out of data.*

    This event is generated when "/kernel: cksum: out of data" is logged in the system log.

    problem-event-kernelcrash.slax

    SYSTEM: writing kernel to

    A kernel crash event. A writing kernel message is captured after the router reboots.

    problem-event-kmem_devbuf.slax

    KERNEL:kmem type devbuf using .*, exceeding limit .*

    The "kmem type devbuf" message reports that the kernel device buffer is allocating more memory than what is available to the kernel.

    problem-event-l2cacheerror.slax

    PFE: L2 Cache Single-bit ECC errors

    The Packet Forwarding Engine component is reporting that Layer 2 Cache Single-bit ECC errors were detected in the last 30 seconds. If the problem persists, this situation is likely to result in a component crash or failure.

    problem-event-lchipcrc.slax

    PFE: LCHIP[(].[)]: (%PFE-.*: )?.* new crcerror errors in NLIF

    The outbound FPC is reporting a corrupt packet received on the Nchip-to-Lchip interface. Another FPC is likely to be causing the packet corruption.

    problem-event-LchipLSIFerrors.slax

    PFE: LCHIP[(].[)]: (%PFE-.*: )?.* new errors in LSIF

    The FPC is reporting L-chip interface errors.

    problem-event-linkerror-iwo_desrd_poll_stream_stats.slax

    PFE: ICHIP[(][0-9][)]: (%PFE-.*: )?New illegal link errors in WO DESRD .* stream_id .*, iwo_desrd_poll_stream_stats

    Potential I-chip stream problem due to logical interface flooding. Refer to [PR 289104]—device may need software upgrade.

    The ICHIP: New illegal link errors system log message indicates a potential I-chip stream problem, possibly due to IFL flooding.

    problem-event-Loss_of_communication.slax

    SYSTEM: Loss of communication with Backup RE

    The “Loss of communication with Backup RE” message is logged each time the master Routing Engine detects loss of keepalive messages being sent from the backup Routing Engine.

    problem-event-LUCHIPuncorrectECC.slax

    LUCHIP(1) RMC 0 Uncorrectable ECC syslog messages

    ECC has detected uncorrectable errors in the LU-chip of an FPC

    problem-event-LUchipWedge.slax

    PFE: LUCHIP Wedge Detected, Active Zones

    The "Wedge Detected, Active Zones" message reports transit traffic congestion on the associated LU-chip on the FPC listed in the system log message.

    problem-event-mbufHighUtil.slax

    kernel: Mbuf: High Utililization Level

    The system log message Mbuf: High Utilization Level reports high memory utilization on the Routing Engine buffers. This message seeks a response to this condition.

    problem-event-mq_fi_linksan.slax

    PFE:MQCHIP(.) FI Link Sanity

    The "FI Link sanity checks" message reports that there are corrupted packets identified by the FPC/MPC during the internal sanity checks at each block in the FPC/MPC.

    problem-event-mqchip_fi_enque.slax

    PFE:MQCHIP(.) FI Reorder Enqueuing error

    The "FI Enqueuing error" message reports that the ASIC chip has an internal queue error in the packet stream traversing the chip.

    problem-event-mqchip_freepool_empty.slax

    PFE:MQCHIP(.*) FI Link cp freepool becomes empty

    The "FI Link cp freepool becomes empty" message reports that the MQ-chip is experiencing a hardware issue on the associated FPC when handling transit cell traffic.

    problem-event-mqchip_timedout.slax

    PFE: MQCHIP[(].[)] timed out waiting for phy_stream

    The "timed out waiting for phy_stream" system log message reports an error found by the MQ-chip in the traffic stream. Most likely the error occurred elsewhere, as the MQ-chip is only detecting the issue.

    problem-event-mqchipCPQ_ECCerror.slax

    PFE:MQCHIP(.) CPQ RLDRAM .* bit ECC error

    The “MQCHIP(.) CPQ RLDRAM .* bit ECC error” message reports that a single or double-bit memory error was detected.

    problem-event-mqchipremPFEfaultdet.slax

    MQCHIP(0): Possible Remote PFE fault detected, err_cell total/rate

    An error is found by the MQ-chip in the traffic stream.

    Note: Most likely, the error occurred elsewhere; the MQ-chip is only detecting the issue.

    problem-event-mqchip-throttle.slax

    PFE:MQchip.*XE.*Throttle: Last.*seconds have seen interrupt throttling at

    The MQ-chip has limited the number of interrupts being triggered on the Packet Forwarding Engine.

    problem-event-mqDDRIFckerr.slax

    PFE:MQCHIP(.) DDRIF FO0 Checksum Error

    The “MQCHIP(.) DDRIF FO0 Checksum Error” reports an error in the checksum of the transit traffic stream through the chip.

    problem-event-mqreordercell.slax

    PFE:MQCHIP(.) FI Reorder cell timeout

    The "FI Reorder cell timeout" message reports a packet drop in fabric traffic.

    problem-event-mrvl_brg_port_cist_init.slax

    PFE:.*mrvl_brg_port_stg_cist_init.*

    Initialization warning message pertaining to MSTP, STP, and RSTP configured ports for any spanning tree groups shared common IST(CIST).

    problem-event-multicasttraffic.slax

    PFE: Failed to find MC RT_NH entry

    Informational message logged when multicast next-hop traffic ages from the switch routing tables.

    problem-event-multicorrectECCDMC.slax

    PFE: Multiple Correctable ECC

    The Packet Forwarding Engine board is reporting multiple correctable ECC memory errors.

    problem-event-multiuncorrectECCDMC.slax

    PFE: Multiple UnCorrectable ECC

    The Packet Forwarding Engine board is reporting multiple uncorrectable ECC memory errors

    problem-event-nfabcrcerror.slax

    PFE: NFAB[(][0-9]/[0-9][)]: (%PFE-.*: )?.*new CRC errors detected

    The fabric connection to the ingress FPC is reporting a bad connection.

    problem-event-nhipcfailed.slax

    KERNEL:RT_PFE: NH IPC failed, err 6 (No Memory)

    The kernel is reporting that the Packet Forwarding Engine cannot install or change routing table entries because it is running out of memory.

    problem-event-oam_lfm_adjacencyloss.slax

    SYSTEM:Adjacency Lost

    The message "Action Syslog on .* [adjacency-loss]: :Adjacency Lost" is reported into the system log message to indicate the occurrence of a link-fault event—that is, Link Adjacency Lost.

    problem-event-oam_lfm_frameerror.slax

    SYSTEM:Frame Error crossed threshold

    The message "Action Syslog on .* [frame-error-event]: :Frame Error crossed threshold .* " is reported in the system log message to indicate the occurrence of a link-fault event—that is, Errored Frame Event.

    problem-event-parityerrordetectedmpfe.slax

    KERNEL:parity error detected, fll reinit: mpfe.*

    The message indicates that the Packet Forwarding Engine was reset when detecting a parity error in the ASIC.

    problem-event-pfecrash.slax

    PFE Crash

    Any Packet Forwarding Engine board crash that occurs in conjunction with a system exception message.

    problem-event-PFEPacketDiscard.slax

    PFE_PACKET_DISCARD_ERROR

    The counter for the /pfe-hardware-statistics/fabric-discard tag from the junoscript call get-pfe-statistics (show pfe statistics) incremented.

    problem-event-pfesendfailed.slax

    Kernel:/kernel: pfe_send_failed, err=32

    This is an internal message generated by the kernel. There is a keepalive message sent to the Packet Forwarding Engine (PFE) to check the status. The kernel missed the keepalive message for the CFEB because of hardware failure.

    problem-event-pfestat_req_receive.slax

    KERNEL:pfestat_req_receive: request.*

    This is a kernel message regarding a Packet Forwarding Engine statistics counter request

    problem-event-phy_eeprom_read_failed.slax

    PFE:phy_BCM8726_read_i2c: pumaj phy eeprom read failed

    When the "phy_BCM8747_read_i2c: phy eeprom read failed" log message is seen on EX 8200 switches, the system missed a read from the EEPROM.

    problem-event-piccrash.slax

    PIC Crash

    Any PIC crash that occurs in conjunction with a system exception message

    problem-event-PIC-PIO-error-indicated.slax

    PFE: PIC.*PIO error indicated

    The "PIC <number> PIO error indicated " message may report that the indicated PIC had connectivity issues or has experienced a hardware failure.

    problem-event-pio_read_error.slax

    PFE: (CMFPC|CMG|CMS): (%PFE-.*: )?PIC ([0-9]*[/]?[0-9]*) PIO Read error, address

    The PIO read error could indicate a hardware issue with the PIC.

    problem-event-pio_write_error.slax

    PFE: CMS: (%PFE-.*: )?PIC .* PIO Write error, address

    The indicated routine failed with a write error at the indicated address and register for the indicated F-chip and link on the indicated Control Board (CB).

    problem-event-pkterror-iwo_hdrf_poll_stats.slax

    PFE: I-CHIP New packet errors in WO HDRF, iwo_hdrf_poll_stats

    Potential I-chip stream problem due to logical interface flooding. Refer to [PR 289104]—device may need software upgrade.

    problem-event-portcommandhandlerfailed.slax

    PFE:port command handler failed processing cmd

    This message is observed, when an error with the incorrect polling status for SFP on copper interfaces occurs.

    problem-event-que_traffic.slax

    PFE:ICHIP(.) Queued traffic in physical queue .* not transmitted

    This message reports that I-chip Queued traffic in a physical queue is not being transmitted. When this condition is seen, the router will automatically changes the CoS configuration for the queue to force the queue to empty. The CoS parameters are then restored after one second.

    problem-event-que_wedge.slax

    PFE:ICHIP(.) Queue Wedge detected in physical queue

    The "Queue Wedge detected in physical queue" message indicates that there was traffic queued on a specific interface queue that was being dropped.

    problem-event-RCHIPSRAMparityerror.slax

    PFE: RCHIP: SRAM parity error

    SRAM parity error detected on FPC R-chip

    problem-event-rdpretransmit.slax

    KERNEL:rdp retransmit error

    The kernel is indicating that no system buffer space is available.

    problem-event-reflective_relay.slax

    PFE:Reflective Relay set Failed

    Reflective relay failed to be enabled on the specified interface.

    problem-event-REmasterswitch.slax

    SYSTEM: Keepalive timeout of *. Assuming RE mastership

    The backup Routing Engine became the master Routing Engine due to a Routing Engine keepalive timeout.

    problem-event-REwatchdog.slax

    Reboot reason(s): 0x2: watchdog

    Routing Engine watchdog timeout event. Related to PSN-2008-07-017 and PR/297313. Event is triggered by string: Reboot reason(s): 0x2: watchdog.

    problem-event-RKME_int_status1.slax

    PFE:SRCHIP(.): RKME int_status 10x100

    RKME is a key match engine located in the FPC SR-chip or R-chip hardware. The RKME engine received the error interrupt shown.

    problem-event-rnhlistdeletedpatnode.slax

    KERNEL:unilist found on the rnhlist_deleted_root patnode

    When graceful Routing Engine Switchover (GRES) is enabled, this message may be logged by the kernel of the master Routing Engine, as it is trying to add a unilist next-hop route; however, there is already a delete request pending acknowledgment from the kernel of the backup Routing Engine. So, the add request is deferred until the delete request is acknowledged. The number printed is the Next Hop Index in the Packet Forwarding Engine.

    problem-event-RTfailedprefixchange.slax

    PFE: RT: Failed prefix change

    These messages indicate that the Routing Engine is trying to delete routes from the Packet Forwarding Engine, but it cannot because the routes do not exist. This usually means the Packet Forwarding Engine has run out of memory. For example, if you bring up many BGP peers, the number of routes the Routing Engine can hold may surpass the number the Packet Forwarding Engine can hold. In this case, the Packet Forwarding Engine runs out of memory and cannot add the routes. Later, when the Routing Engine tries to remove the routes, the prefix looks for is unknown.

    problem-event-rtprefixadd.slax

    KERNEL:RT_PFE: RT msg op 1 (PREFIX ADD) failed

    When the Routing Protocol Process (rpd) is running out of all available memory, the kernel may fail to allocate memory for new prefixes. In this case a message of the following form may appear in the System log message file: kernel: RT_PFE: RT msg op 1 (PREFIX ADD) failed, err 6 (No Memory).

    problem-event-scheduler_oinker.slax

    SYSTEM: SCHED: Thread.*ran for.*without yielding

    "Scheduler Oinker" messages seen on the console when a single thread of execution does not release itself from memory and CPU resources.

    problem-event-SDRAMECCerror.slax

    PFE: SDRAM ECC Error

    Any Packet Forwarding Engine SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name fpc0 ADPC: detected 1 DDR SDRAM Single-bit ECC errors in the last 30 seconds

    problem-event-SDRAMECCmultibiterror.slax

    PFE: DDR SDRAM Error: (%USER-.*: )?Multi-bit ECC error

    The Packet Forwarding Engine (PFE) detected a multi-bit Error Correcting Code (ECC) error. This is a hardware error correctable by replacement of the failed hardware. The log messages also identifies the device that has failed.

    problem-event-SFPlowpower.slax

    PFE:.SFP receive power low warning

    This event indicates that the SFP has received power low warning.

    problem-event-SHEAFleakerror.slax

    PFE: SHEAF: possible leak

    Possible FPC SHEAF memory leak.

    problem-event-SIB_STATE_OFFLINE_ACK_WAIT.slax

    PFE:SIB_STATE_ONLINE-> SIB_STATE_OFFLINE_ACK_WAIT

    When a "state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT" event occurs, a message similar to one of the following is reported:

    sfc0-spmb0 CMGSIB: SIB #14 state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT sfc0-spmb0 CMGSIB: %PFE-6: SIB #1 state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT

    This message may be associated with one or more of the following messages in the system log output:

    CMGSIB: SIB #0 state transition SIB_STATE_OFFLINE_ACK_WAIT -> SIB_STATE_OFFLINE CMGSIB: cmg_sib_button_action(): 0 CMGSIB: Offline button request for SIB 0 CMGSIB: %PFE-3: SIB#1 voltage outside tolerance! spmb0 CMGSIB: SIB#0 voltage outside tolerance for channel: 10! sfc0-spmb0 CMGSIB: %PFE-3: Taking SIB#1 offline! chassisd[3247]: CHASSISD_FRU_OFFLINE_NOTICE: Taking SIB 1 offline: Offlined by cli command chassisd[2906]: CHASSISD_SNMP_TRAP10: SNMP trap generated: FRU power off (jnxFruContentsIndex 15, jnxFruL1Index 22, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName SFC0 SIB F2S 1/2, jnxFruType 9, jnxFruSlot 21, jnxFruOfflineReason 7, jnxFruLastPowerOff 423594357, jnxFruLastPowerOn 159058) When a SIB goes offline, this can trigger an alarm on the system."

    problem-event-smqchipreddrops.slax

    SMQCHIP(0) Fabric RED drops

    The SMQ-chip has reported fabric RED drops

    problem-event-sonn_errors.slax

    PFE:SONN errors

    The "SONN errors" message is logged periodically when the FPC loses track of notification cell traffic and reports the number of frames dropped.

    problem-event-SRCHIPSRAMparityerror.slax

    • PFE: SRCHIP[(].[)]: (%PFE-.*: )?SRAM parity error at loc

    SRAM parity error detected on FPC RCHIP

    problem-event-TCAMERROR.slax

    PFE: Route TCAM rows could not be redirected on device

    The TCAM error messages listed indicate a permanent nonfixable error with TCAM, if they persist after rebooting the EX Series switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are harmful. ACLs will be unreliable on this FPC.

    problem-event-tempwarm.slax

    SYSTEM: Alarm set: Temp Too Warm

    The system is indicating that the sensor on an EX Series FPC is exceeding the temperature threshold.

    problem-event-toxicsfp.slax

    PFE: TOXIC SFP

    Junos OS marks an SFP as toxic and logs the TOXIC SFP message when communication through the I2C (the bus through which the router monitors the SFP and updates diagnostic data) bus fails.

    problem-event-ucode_data_error.slax

    PFE:Errors ucode data error

    The "Errors ucode data error" message is logged each time an ASIC fails its periodic code check.

    problem-event-uncorrectECCerror.slax

    • PFE: BCHIP .*: (%PFE-.*: )?multiple uncorrectable ECC error

    The Packet Forwarding Engine board is reporting multiple uncorrectable ECC memory errors.

    problem-event-unknownencapsohead.slax

    SYSTEM:.*dcd.* unknown encaps_ohead; dev vlan, encaps .* flags.*

    Informational message generated by the dcd deamon in system log when certain protocols and VLANs are configured (for example, MSTI, VRRP).

    problem-event-vlanMACfilter.slax

    KERNEL:vlan MAC filter: .* from port .* rejected

    If a protocol is not configured on an EX Series device but receives Virtual Router Redundancy Protocol (VRRP) packets, all VRRP packets are dropped in the kernel with the /kernel: vlan MAC filter: 01:00:5e:00:05: reject message in /var/log/ messages.

    This message is seen when packets arrive for all those protocol packets for which the EX Series device is not configured or enabled. When routed VLAN interface (RVI) is configured on a VLAN, a copy of all L3 multicast control packets such as OSPF, (VRRP), and Protocol Independent Multicast (PIM)) is sent to the kernel.

    problem-event-voltage_fail_shutdown.slax

    KERNEL:.*Voltage Fail Shutdown.*device.*

    The Voltage Fail Shutdown message is reported in the system message file if the indicated device in the system log message has or is about to be reset or due to improper grounding of the FRU causing it to go offline.

    problem-event-wanqwedge.slax

    PFE: imq_stream_disable_stream

    The imq_stream_disable_stream message is logged when an internal part of the I-chip is unable to clear data to make room for new data streams. The message indicates that the queue was not drained within 200ms; so, the software stopped trying to disable the queue.

    problem-event-WRITE_DMAerror.slax

    KERNEL:.*WRITE_DMA UDMA ICRC error.*

    This message is seen when there is hardware fault on the hard drive or communication between the hard drive and kernel or Routing Engine and the motherboard.

    problem-event-xfchipCRCerrors.slax

    SYSTEM:New CRC errors found on xfchip

    The "New CRC errors found on xfchip" message indicates that there are errors on the high-speed link between an FPC or DPC card and the associated SCB.

    problem-event-xmreordercell.slax

    PFE:XMCHIP(.): FI: Reorder cell timeout

    The "XMCHIP(.): FI: Reorder cell timeout" message indicates that no further traffic is sent to the fabric due to packet drops.

    problem-interval-vpls_drops.slax

    INTERVAL: ICHIP non-RED vpls tail drops

    The script associated with this event checks for non-red packets (tails drops) on all FPCs with tunnel-services enabled.

    problem-interval-vpls_traffic.slax

    INTERVAL: VPLS tunnel usage exceeded threshold

    The event script checks periodically to see if any tunnel interface (vt-*/*/*) is experiencing usage of 65% or greater.

    Modified: 2017-02-01