Advanced Insight Scripts (AI-Scripts) Operation

This sections describes the various modes of operation and the operations that can be done on AI-Scripts.

AI-Scripts Operation

AI-Scripts do the following tasks:

AI-Script Modes

AI-Scripts operate in three distinct modes:

Using Service Now and Service Insight Without Deploying AI-Scripts in Junos OS Devices

In Junos Space 12.2, users can generate on-demand Incidents without installing AI-Scripts via Service Now Event Profile. In this case, users need to select the ’Use Service Now to Generate Incident’ checkbox to create an On-demand Incident. Service Now will collect the information required to construct an Incident, from the existing Device Management Interface (DMI) connection. If the check box is not selected, AI-Scripts must be installed in the device; else an on-demand Incident will not be generated.

Without deploying AI-Scripts in target devices, generating an event-based Incident is not possible. Only on-demand Incidents can be generated.

Using Service Now and Service Insight with AI-Scripts Installed in Junos OS Devices

AI-Scripts must be installed in Junos OS devices to generate event-based Incidents in Service Now. Optimizations introduced in this release, substantially reduce the processing and memory required to generate Service Now Incidents on resource constrained devices such as low-end firewall and switch products. This helps in using AI-Scripts effectively in a larger number of Junos platforms. However, there is a tradeoff – limited diagnostic information is collected for branch SRX and low-end EX devices. Inspite of these improvements, system resources are still consumed when Service Automation is active in Junos OS devices. As a result, Juniper recommends to test and qualify Service Automation before deploying it in a production environment. See section Platforms Supported by AI-Scripts for a complete list of supported platforms.

Platforms Supported by AI-Scripts

Table 1 lists the active Junos OS platforms supported by Release 3.7 of AI-Scripts.

Table 1: Platforms Supported by AI-Scripts

Platform Family

Platform

ACX Series

ACX2000

ACX2100

ACX2200

EX Series

EX2200

EX3200

EX3300

EX4200

EX4500

EX4550

EX6210

EX8208

EX8216

EX9208

 

EX Virtual Chassis Series

EX3300-VC

EX4200-VC

EX4500-VC

EX6200-VC

MIXED-MODE-EX-VC

EX-XRE

QFX Series

FX-JVRE

QFX3500

QFX3500S

QFabric System

J Series

J2320

J2350

J4350

J6350

SRX Series (Branch)

SRX110

SRX210

SRX220

SRX240

SRX550

SRX650

SRX Series (Data Center)

SRX1400

SRX3400

SRX3600

SRX5600

SRX5800

 

LN Series

LN1000

LN2600

M Series

M10I

M120

M320

M40E

M7I

MX Series

MX10

MX2010

MX2020

MX240

MX40

MX480

MX5

MX80

MX960

T Series

M320

T1600

T320

T4000

T640

TX Matrix Series

TX Matrix

TX Matrix Plus

Platforms Not Recommended for AI-Scripts Production Deployment

Table 2 lists the active Junos OS platforms that are currently not recommended for AI-Scripts production deployment. The installation of AI-Scripts on these platforms could exhaust the system resources and testing will not be completed during the time of publication. The full support of AI-Scripts on these platforms is planned for future releases of AI-Scripts and Junos OS. This coverage change only applies to this release of AI-Scripts; and not to Junos Space or the applications running on Junos Space. Table 2 displays the complete list of devices in which installing AI-Scripts is not recommended. See section Using Service Now and Service Insight Without Deploying AI-Scripts in Junos OS Devices to generate on-demand incidents without installing AI-Scripts.

Table 2: Junos Platforms Not Recommended for AI-Scripts Production Deployment

Platform Family

Platform

ACX Series

ACX1000

ACX1100

SRX Series (Branch)

SRX100

Events Detected by AI-Scripts

Table 3 lists the events detected by Release 3.7 of AI-Scripts.

Table 3: Events Detected by AI-Scripts

Event ID

Description

ACCT_MALLOC_FAILURE

The accounting statistics process could not allocate memory from the heap.

ACCT_XFER_POPEN_FAIL

A failed call to the popen() function when the accounting statistics process invokes the indicated command to transfer the indicated file.

ASP_IDS_INV_CLEAR_QUERY

The intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request includes the indicated type of query, which the IDS cannot interpret.

ASP_IDS_INV_CLEAR_QUERY_VER

The intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request version number did not match the version number of requests that the IDS can service.

ASP_L2TP_NO_MEM

The Layer 2 Tunneling Protocol (L2TP) could not allocate the memory it needed to create a flow for the indicated tunnel and session.

ASP_L2TP_OBJ_CAC_FAIL

The Layer 2 Tunneling Protocol (L2TP) could not allocate memory from an object cache for the flow defined by the indicated unit, tunnel, and session.

ASP_PGCP_IPC_MSG_WRITE_FAILED

The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write an inter-process communication (IPC) message to the end of its pipe.

ASP_PGCP_IPC_PIPE_WRITE_FAILED

The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write the contents of its inter-process communication (IPC) pipe to the socket layer.

AUDITD_RADIUS_OPEN_FAILED

The audit process (auditd) could not create a RADIUS object handle used for various RADIUS operations.

AUDITD_RADIUS_REQ_CREATE_FAILED

The audit process (auditd) could not create a RADIUS accounting request for the indicated reason.

AUDITD_SOCKET_FAILURE

The audit process (auditd) listens on a Transmission Control Protocol (TCP) socket for system accounting events reported by other processes on the device. The indicated socket operation failed with the indicated error.

AUTHD_AUTH_CREATE_FAILED

The generic authentication service process (authd) could not allocate an authentication object for the indicated reason.

AUTHD_SERVER_INIT_BIND_FAIL

The generic authentication service process (authd) could not bind the server to the address specified.

SYSTEM:Alarm set: CB color=RED, class=CHASSIS, reason=CB

The "CB . Failure" message reports a hardware issue. Usually this is with the referenced Control Board, although sometimes it may be with an FPC.

SYSTEM:Alarm set RE Host hard-disk drive error

The ""hard-disk drive error"" message reports that a hard drive on the specified Routing Engine is no longer available to the kernel. Usually, either the message is reported from the Backup Routing Engine, or the Master Routing Engine gets the boolist corrupted, reboots to fix that, and in the process Routing Engine Mastership switches. If there is only one Routing Engine, it will reboot also on occurrance of this message. At that point the affected Routing Engine will run off its alternate media, usually Compact Flash.

AUTHD_SERVER_INIT_LISTEN_FAIL

The generic authentication service process (authd) could not initialize listening on the server for the indicated socket.

AUTHD_SETSOCKOPT_FAILED

The generic authentication service process (authd) could not set socket options during the indicated operation.

AUTHD_SOCKET_FAILED

The generic authentication service process (authd) could not open a socket during the indicated operation.

AUTOCONFD_AUTH_NO_MEM

The memory allocation (malloc) for username authentication failed.

AUTOD_RECV_FAILURE

The autoinstallation process (autod) received the indicated error when it tried to receive data on a socket.

AUTOD_SEND_FAILURE

The autoinstallation process (autod) receives the indicated error when it sends data on a socket.

AUTOD_SOCKET_CREATE_FAILURE

The autoinstallation process (autod) receives the indicated error when it creates a socket.

AV_PATTERN_KL_CHECK_FAILED

The device is unable to use the Kaspersky pattern file. The error message provides information to give to Juniper Networks technical support.

AV_PATTERN_TOO_BIG

The pattern file size specified in the server initialization file (server.ini) exceeds the maximum prescribed limit.

AV_PATTERN_WRITE_FS_FAILED

The device is unable to save the contents of an antivirus pattern file to the file system.

BFDD_READ_ERROR

The bidirectional forwarding detection process (bfdd) could not read a message available on the indicated type of pipe.

BFDD_WRITE_ERROR

The bidirectional forwarding detection process (bfdd) could not write a message to the indicated type of pipe.

BOOTPD_HWDB_ERROR

The boot parameter process (tnp.bootpd) could not complete an operation in the hardware database maintained by the chassis process (chassisd), for the indicated reason.

CFMD_RTSOCK_OPEN_FAILURE

The connectivity fault management process (cfmd) could not successfully open a routing socket to the kernel, for the indicated reason.

CHASSISD_BUS_DEVICE_OPEN_FAILURE

The chassis process (chassisd) could not open the indicated bus device, for the indicated reason.

CHASSISD_CFEB_POWER_FAILURE

The chassis process (chassisd) could not turn on or turn off the power to the indicated Compact Forwarding Engine Board (CFEB).

CHASSISD_CLOCK_FAILURE

The chassis process (chassisd) determined that the indicated clock source failed in the indicated way.

CHASSISD_CMB_READBACK_ERROR

The chassis process (chassisd) could not read back information from the Chassis Management Bus (CMB) about the indicated component (field-replaceable unit, or FRU).

CHASSISD_COMMAND_ACK_ERROR

The chassis process requested that the indicated component (field-replaceable unit, or FRU) confirm that it was online. The indicated error occurred when the FRU sent its response. In the normal case, the chassis process performed any additional action necessary to guarantee that the FRU came online.

CHASSISD_COMMAND_ACK_SFM_ERROR

The chassis process (chassisd) requires an acknowledgment from each Switching and Forwarding Module (SFM) before it registers a Flexible PIC Controller (FPC) as online. The acknowledgment message from the indicated SFM failed for the indicated FPC.

CHASSISD_FAN_FAILURE

The indicated fan or impeller failed. The chassis process (chassisd) raised an alarm and increased the speed of the remaining fans (and impellers, if applicable) to full speed.

CHASSISD_FASIC_FTOKEN_ERROR

The chassis process (chassisd) detected an underflow or overflow error on the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_FTOKEN_INIT_ERROR

The chassis process (chassisd) encountered an error while initializing memory at the indicated address for the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_HSL_CONFIG_ERROR

The chassis process (chassisd) could not configure high-speed links (HSL) for the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_HSL_LINK_ERROR

The chassis process (chassisd) detected an error for the indicated high-speed link (HSL) for the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_INIT_ERROR

The chassis process (chassisd) detected that F chips were not yet initialized on the Control Board (CB).

CHASSISD_FASIC_INPUT_DROP

The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data that was received from the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per second.

CHASSISD_FASIC_OUTPUT_DROP

The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data before sending it to the indicated Packet Forwarding Engine on the indicated Flexible Port Concentrator (FPC) for outgoing transmission, it dropped the indicated number of cells per second.

CHASSISD_FASIC_PIO_READ_ERROR

The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB).

CHASSISD_FASIC_PIO_WRITE_ERROR

The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB).

CHASSISD_FASIC_PLL_ERROR

The chassis process (chassisd) could not lock a phased-lock loop (PLL) for the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_RESET_ERROR

The chassis process (chassisd) could not reset the indicated F chip on the indicated Control Board (CB).

CHASSISD_FASIC_SRAM_ERROR

The chassis process (chassisd) detected that SRAM failed to initialize for the indicated F chip on the indicated Control Board (CB).

CHASSISD_FCHIP_CONFIG_MD_ERROR

The chassis process (chassisd) detected an invalid number of Md chips for the indicated F chip, Packet Forwarding Engine, and Flexible PIC Concentrator (FPC).

CHASSISD_FCHIP_HSR_ERROR

The chassis process (chassisd) detected an error in the high-speed receiver (HSR) subsystem for the F chip with the indicated characteristics.

CHASSISD_FCHIP_HST_ERROR

The chassis process (chassisd) detected an error in the high-speed transmitter (HST) subsystem for the F chip with the indicated characteristics.

CHASSISD_FCHIP_LINK_ERROR

The chassis process (chassisd) detected an error for the indicated high-speed receiver (HSR) or high-speed transmitter (HST) link for an F chip on the indicated Switch Interface Board (SIB).

CHASSISD_FCHIP_MONITOR_ERROR

The chassis process (chassisd) detected an invalid F-chip module while enabling or disabling the monitoring of F-chip functional blocks.

CHASSISD_FCHIP_PIO_READ_ERROR

The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link.

CHASSISD_FCHIP_PIO_WRITE_ERROR

The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link.

CHASSISD_FEB_SWITCHOVER

The chassis daemon (chassisd) switched to the indicated FEB from the specified FEB.

CHASSISD_FHSR_READ_REG_ERROR

The high-speed receiver (HSR) read routine failed at the indicated address on an F-chip register.

CHASSISD_FHSR_WRITE_REG_ERROR

The high-speed receiver (HSR) write routine could not record the indicated value at the indicated address on an F-chip register.

CHASSISD_FHST_READ_REG_ERROR

The high-speed transmitter (HST) read routine failed at the indicated address on an F-chip register.

CHASSISD_FHST_WRITE_REG_ERROR

The high-speed transmitter (HST) write routine could not record the indicated value at the indicated address on an F-chip register.

CHASSISD_FILE_OPEN

The chassis process (chassisd) could not open the indicated file for the indicated reason.

CHASSISD_FM_ERROR

During execution of the indicated fabric management routine, the indicated error occurred between the indicated Switch Interface Board (SIB) and the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC).

CHASSISD_FM_ERROR_F13_FB_HSR_TXP

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected an error in the electrical path between the indicated ports on the F13SIB and the indicated ST-SIB-L on the indicated LCC.

CHASSISD_FM_ERROR_F13_FB_RX_VC

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the in the optical media from the indicated ST-SIB-L on the indicated LCC.

CHASSISD_FM_ERROR_F13_FB_TX_VC

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

CHASSISD_FM_ERROR_SIB_L_FB_HSR

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T640 router (called SIB-Ls) and the SIBs in the TX Matrix platform (called SIB-Ss). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected an error in the electrical path between the indicated ports on the SIB-L and the corresponding SIB-S.

CHASSISD_FM_ERROR_SIB_L_FB_SMF

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix (the switch-card chassis, or SCC) and the SIBs in the T640 routers (called SIB-Ls). The chassis process (chassisd) on the T640 router that houses the indicated SIB-L detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

CHASSISD_FM_ERROR_SIB_S_FB_HSR

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routers (called SIB-Ls). The chassis process (chassisd) on the TX Matrix detected an error in the electrical path between the indicated port on the indicated SIB-S and the indicated port on a SIB-L installed in the indicated T640 router (line-card chassis, or LCC).

CHASSISD_FM_ERROR_SIB_S_FB_SMF

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix (called SIB-Ss) and the SIBs in the T640 routers (line-card chassis, or LCCs). The chassis process (chassisd) on the TX Matrix platform detected the indicated error as packets that were traveling to or from the indicated LCC were translated between electrical and optical media.

CHASSISD_FM_SIB_ERROR

The chassis process (chassisd) detected the indicated type of error on the indicated Switch Interface Board (SIB) and performed the indicated action.

CHASSISD_FPC_PIC_DETECT_TIMEOUT

The chassis process (chassisd) expects to receive notification within a timeout period that each Flexible PIC Concentrator (FPC) has attached the PIC that it houses. It did not receive notification from the indicated FPC.

CHASSISD_FRU_INVALID_SLOT

The chassis process (chassisd) detected that the indicated hardware component (field-replaceable unit, or FRU) was inserted in a slot that is not valid for that component type.

CHASSISD_FRU_IO_ERROR

The chassis process (chassisd) could not perform the indicated I/O operation on the indicated component (field-replaceable unit, or FRU).

CHASSISD_FRU_OFFLINE_NOTICE

The chassis process (chassisd) took the indicated component (field-replaceable unit, or FRU) offline for the indicated reason.

CHASSISD_GBUS_NOT_READY

The GBUS was not ready when the chassis process (chassisd) first tried to power it on, and the power-up operation timed out.

CHASSISD_GBUS_READBACK_ERROR

There was an error when the chassis process (chassisd) tried to read back information from the GBUS on the indicated component (field-replaceable unit, or FRU).

CHASSISD_HSR_FIFO_ERROR

A first-in, first-out (FIFO) read error occurred during execution of the indicated routine on the indicated high-speed receiver (HSR).

CHASSISD_HWDB_ERROR

The operation performed on the hardware database was unsuccessful.

CHASSISD_I2C_BAD_IDEEPROM_FORMAT

The chassis process (chassisd) determined that the ID EEPROM format specified for the indicated type of hardware component (field-replaceable unit, or FRU) is not valid for it.

CHASSISD_I2C_READ_ERROR

The chassis process (chassisd) cannot read I2C data from the indicated device.

CHASSISD_I2CS_READBACK_ERROR

The chassis process (chassisd) cannot read back information from the I2C slave (I2CS) about the indicated component (field-replaceable unit, or FRU).

CHASSISD_IFDEV_DETACH_FPC

The chassis process (chassisd) detached the interface devices for all PICs on the indicated Flexible PIC Concentrator (FPC).

CHASSISD_IFDEV_DETACH_PIC

The chassis process (chassisd) detached the interface devices for the indicated PIC.

CHASSISD_IPC_CONNECTION_DROPPED

The chassis process (chassisd) dropped the interprocess communication (IPC) connection to the indicated component (field-replaceable unit, or FRU).

CHASSISD_IPC_DAEMON_WRITE_ERROR

The chassis process (chassisd) could not write to a socket because of the indicated error. The socket is for a connection to another process that runs on the Routing Engine and helps manage the chassis.

CHASSISD_IPC_MSG_DROPPED

The chassis process (chassisd) dropped an interprocess communication (IPC) message because the message queue had already reached maximum capacity.

CHASSISD_IPC_MSG_UNHANDLED

The chassis process (chassisd) received an interprocess communication (IPC) message about the indicated FRU. The message had the indicated characteristics. chassisd could not handle the message.

CHASSISD_IPC_WRITE_ERR_NULL_ARGS

The chassis process (chassisd) could not send a message to the indicated component (field-replaceable unit, or FRU) because one or more required parameters had a null value.

CHASSISD_ISSU_ERROR

The chassisd process (chassisd) encountered an error during the In Service Software Upgrade Process.

CHASSISD_MAC_ADDRESS_ERROR

The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated interface because of an internal error.

CHASSISD_MAC_ADDRESS_FABRIC_ERROR

The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated fabric interface because of an internal error.

CHASSISD_MALLOC_FAILURE

The chassis process (chassisd) could not allocate memory. chassisd tried to continue functioning, but the lack of memory usually causes the process to fail. An administrator needs to restart it.

CHASSISD_MBE_DETECTED

A multibit ECC parity error was detected in the Routing Engine DRAM.

CHASSISD_OVER_TEMP_CONDITION

The temperature of one or more components (field-replaceable units, or FRUs) exceeded the indicated temperature, which is the upper of two thresholds. The fans (and impellers, if applicable) were in the indicated state. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, chassisd shuts down the device. When this message was logged, the indicated number of seconds remained before shutdown.

CHASSISD_OVER_TEMP_SHUTDOWN_TIME

The chassis process (chassisd) shut down the device because the temperature of one or more components exceeded the indicated threshold temperature for the indicated amount of time. Continued operation at the excessive temperature could damage the device.

CHASSISD_PEM_INPUT_BAD

The chassis process (chassisd) detected the indicated error condition for the indicated power entry module (PEM).

CHASSISD_PEM_OVERLOAD

The indicated power entry module (PEM) reported an output voltage overload condition.

CHASSISD_PEM_TEMPERATURE

The chassis process (chassisd) detected that the 'temperature check bit' was set in the status bit mask for the indicated power entry module (PEM).

CHASSISD_PEM_VOLTAGE

The indicated power entry module (PEM) reported a problem with its output voltage.

CHASSISD_PIC_HWERROR

The indicated PIC experienced a hardware error. The chassis process (chassisd) did not bring the PIC online.

CHASSISD_POWER_CHECK

The chassis process (chassisd) could not power up the indicated component (field-replaceable unit, or FRU), because the FRU did not respond.

CHASSISD_POWER_CONDITION

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds.

CHASSISD_PSU_ERROR

The chassis process (chassisd) detected the indicated error condition for the indicated power supply unit (PSU).

CHASSISD_PSU_FAN_FAIL

The PSU fan-fail bit is set in the status for the indicated power supply unit (PSU).

CHASSISD_PSU_INPUT_BAD

The chassis process (chassisd) detected the input voltage/warning fault condition for the indicated power supply unit (PSU).

CHASSISD_PSU_OVERLOAD

The indicated power supply unit (PSU) reported an output voltage overload condition.

CHASSISD_PSU_TEMPERATURE

The chassis process (chassisd) detected that the temperature check bit was set in the status bit mask for the indicated power supply unit (PSU).

CHASSISD_PSU_VOLTAGE

The indicated power supply unit (PSU) reported a problem with its output voltage.

CHASSISD_RE_OVER_TEMP_CONDITION

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds.

CHASSISD_RE_OVER_TEMP_SHUTDOWN

The chassis process (chassisd) performed the indicated action because the temperature of the indicated Routing Engine exceeded the maximum threshold for more than four minutes. Continued operation at the excessive temperature could damage device components.

CHASSISD_RE_OVER_TEMP_WARNING

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, chassisd shuts down the indicated component. When this message was logged, the indicated number of seconds remained before shutdown.

CHASSISD_SBE_DETECTED

Too many single-bit correctable ECC parity errors were detected in Routing Engine DRAM.

CHASSISD_SHUTDOWN_NOTICE

Although the chassis process (chassisd) normally does not exit or shut down except when the Routing Engine reboots, it shut down for the indicated reason.

CHASSISD_SIB_INVALID_SLOT

The chassis process (chassisd) detected the presence of a Switch Interface Board (SIB) in an invalid slot. The SIB remains offline.

CHASSISD_SMB_INVALID_PS

The chassis process (chassisd) could not set the status (enabled or disabled) for a power supply because it received the indicated power supply status code, which is invalid.

CHASSISD_SMB_IOCTL_FAILURE

The indicated ioctl() operation failed at the indicated address on the system management bus (SMB).

CHASSISD_SMB_READ_FAILURE

A read() operation failed at the indicated address on the system management bus (SMB).

CHASSISD_TEMP_SENSOR_FAILURE

The temperature sensor for the indicated component (field-replaceable unit, or FRU) either did not respond to a request from the chassis process (chassisd) for a temperature reading or sent a value that is outside the normal operating range.

CHASSISD_TIMER_VAL_ERR

The chassis process (chassisd) started a timer to track the timeout period for an event. The timer returned a null identifier, so chassisd could not clear the timer.

CHASSISD_UNEXPECTED_EXIT

The chassis process (chassisd) exited unexpectedly and reported the indicated error.

CHASSISD_VOLTAGE_READ_FAILED

The chassis process (chassisd) could not read the voltage data from the indicated component (field-replaceable unit, or FRU).

CHASSISD_VOLTAGE_SENSOR_INIT

The chassis process (chassisd) could not initialize the voltage sensor for the indicated component (field-replaceable unit, for FRU).

CONNECTION_CHASSISD_FAIL

The alarm process (alarmd) was unable to connect to the chassis process (chassisd).

CONNECTION_CRAFTD_FAIL

The alarm process (alarmd) was unable to connect to the craft process (craftd).

CONNECTION_RTLOGD_FAIL

The alarm process (alarmd) was unable to connect to the Juniper Networks J Series Services Router (JSR) log process (rtlogd).

CONNECTION_SEND_ERROR

The alarm process (alarmd) received an error while it was trying to send a message.

COSD_GENCFG_WRITE_FAILED

The class-of-service (CoS) process (cosd) uses GENCFG to read and write data from the kernel. If the write fails, the kernel returns an error.

COSD_MALLOC_FAILED

The class-of-service (CoS) process (cosd) could not dynamically allocate memory, for the indicated reason.

COSD_RTSOCK_LIB_ERR

The class-of-service (CoS) process (cosd) uses rtsock library for reading and writing data from and to kernel. The specified error occurred while using rtsock library to read/write data.

COSD_RTSOCK_WRITE_FAILED

The class-of-service (CoS) process (cosd) uses rtsock to read/write data from kernel. If the write fails kernel returns an error.

COSD_UNEXPECTED_EXIT

The class-of-service (CoS) process (cosd) waits for the event notifications and processes the events that it is registered for. There was an error during event-handling initialization.

COSD_UNKNOWN_TRANSLATION_TABLE

The class-of-service (CoS) process (cosd) did not recognize the indicated translation table type from the rtsock library.

Daemon Crash

A Junos OS daemon crash occurred with a core dump.

DCD_CONFIG_WRITE_FAILED

The interface process (dcd) encountered an error while trying to send an interface configuration to the kernel over the routing socket.

DCD_GET_ERROR

The interface process (dcd) encountered an error while trying to load the kernel interface configuration over the routing socket.

DCD_PARSE_STATE_EMERGENCY

The interface process (dcd) encountered an unhandled internal state during interface parsing.

DCD_RTSOCK_READ_SYNC_NOBUF

The interface process (dcd) communicates with the kernel by writing messages to and reading messages from routing sockets. The DCD could not allocate memory to use to read messages from the kernel.

DCD_RTSOCK_SEND_NOBUF

If the Routing Engine is busy or operating under a heavy load, messages between the interface process (dcd) and the kernel may be dropped. To detect whether messages have been dropped, dcd and the kernel place sequence numbers in messages. dcd detected that a message was dropped. In an attempt to recover the message, dcd retries the operation.

DCD_TRASHED_RED_ZONE

When DCD is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when de-allocating this memory, DCD checks for the pattern. Not finding the previously written pattern means the memory was overwritten, which indicates an error in DCD.

DFCD_GENCFG_MALLOC_FAILED

The dynamic flow capture process (dfcd) could not allocate memory for the GENCFG message.

DFCD_GENCFG_WRITE_FAILED

The dynamic flow capture process (dfcd) could not send the GENCFG message for the indicated reason.

DFCD_LINH_MALLOC_FAILED

The dynamic flow capture process (dfcd) could not allocate memory for the LINH message.

DFWD_CONFIG_WRITE_FAILED

The firewall process (dfwd) encountered an error while trying to send an interface configuration to the kernel over the routing socket.

DFWD_MALLOC_FAILED

The firewall process (dfwd) must dynamically malloc memory for its needs. This allocation request failed. The specific data structure that was being allocated is listed in the message.

DFWD_PARSE_STATE_EMERGENCY

The firewall process (dfwd) encountered an unhandled internal state while parsing an interface.

DFWD_TRASHED_RED_ZONE

When the firewall process (dfwd) is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when de-allocating this memory, dfwd checks for the pattern. Not finding the previously written pattern means the memory was overwritten, which indicates an error in dfwd.

DH_SVC_LOGIN_FAILURE

The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not log the client in with the indicated application and the indicated session ID on the indicated interface (interface name) due to the indicated failure (pre-authentication or post-authentication failure).

DH_SVC_RTSOCK_OPEN_FAILURE

The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error.

DH_SVC_RTSOCK_REGISTER_FAILURE

The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully register a callback function with a routing socket. The error string accompanying this log entry indicates the specific error.

DH_SVC_SETSOCKOPT_FAILURE

The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not set the indicated socket option.

DH_SVC_SOCKET_FAILURE

The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not create a socket.

ESPTASK_PARSE_BAD_SWITCH

This process terminated because of an invalid option.

ESPTASK_PARSE_CMD_ARG

This process terminated because of an internal error.

ESPTASK_PARSE_CMD_EXTRA

This process terminated because of an invalid option.

ESWD_DAI_FAILED

The ARP request/response received on this port cannot be linked to any of the IPs assigned by DHCP.

ESWD_DHCP_UNTRUSTED

DHCP server packets are being received on a port that was not meant to receive server traffic.

ESWD_PPM_READ_ERROR

The ethernet bridging process (eswd) could not read a message available on the read pipe from the periodic packet management process (ppmd).

ESWD_PPM_WRITE_ERROR

The ethernet bridging process (eswd) could not write a message on the pipe to the periodic packet management process (ppmd).

ESWD_ST_CTL_ERROR_IN_EFFECT

This condition occurs when storm control error condition is detected.

ESWD_STP_BASE_MAC_ERROR

This condition occurs when STP cannot derive the base MAC address of the system.

EVENTD_EVENT_SEND_FAILED

Junos OS processes can request that the event processing process (eventd) notify them when a specific event occurs. eventd could not send an event notification for the indicated reason.

EVENTD_FORK_ERR

The event processing process (eventd) could not create a child process for executing policies.

EVENTD_PIPE_ERR

The event processing process (eventd) could not create a pipe for interprocess communication.

EVENTD_VERSION_MISMATCH

The event processing process (eventd) received an event with the indicated version indicator, which does not match the indicated version expected by eventd.

FPCLOGIN_IP_ADDRESS_GET_FAILURE

The fpclogin module attempted to get the IP address of the physical interface module. The attempt failed.

FSAD_ERROR

The file system access process (fsad) internal error message.

FUD_MEMORY_ALLOCATION_FAILURE

The UDP forwarding process (fud) could not allocate the indicated amount of memory from the heap.

FUD_RTSOCK_WRITE_FAILURE

The UDP forwarding process (fud) could not write to its routing socket for the indicated reason.

FUD_SENDMSG_FAILURE

The UDP forwarding process (fud) could not send data to the indicated destination port and address using the indicated interface and routing instance, which it needs to do during normal operation.

FUD_SENDMSG_NOINT_FAILURE

The UDP forwarding process (fud) could not send data to the indicated destination port and address using the indicated routing instance, which it needs to do during normal operation.

FUD_SETSOCKOPT_FAILURE

The UDP forwarding process (fud) could not set the indicated socket option.

FUD_SOCKET_FAILURE

The UDP forwarding process (fud) could not create a socket.

GGSN_ALARM_TRAP_SEND

An alarm trap to be relayed by the services PICs process (serviced) failed to initialize.

GGSN_TRAP_SEND

The system sent a GGSN trap of an unrecognized type.

GRAPH_NO_MEMORY

The graphing process could not allocate memory while trying to create a graph.

HNCACHED_PATRICIA_ERROR

A call to a Patricia tree library function returns an error.

ICCPD_ASSERT_SOFT

The source code for the interchassis communication process (iccpd) includes internal self-consistency checks. As iccpd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. iccpd created a diagnostic core file for analysis by technical support personnel and continued to run.

ICCPD_OPEN_ERROR

The interchassis communication process (iccpd) could not initialize.

IDP_DAEMON_INIT_FAILED

An attempt to start the IDP policy daemon failed because an error was encountered during initialization.

IDP_INTERNAL_ERROR

The IDP daemon encountered an internal error.

IKED_CFG_PATRICIA_ERROR

A call to a Patricia tree library function returned an error.

INTERVAL: ICHIP non-RED vpls tail drops

The script associated with this event will check for non-red packets (tails drops) on all FPCS with tunnel-services enabled.

INTERVAL: VPLS tunnel usage exceeded threshold

The event script checks periodically to see if any tunnel interface (vt-*/*/*) is experiencing usage of 65% or greater.

JCS_BBD_LOAD_FAILURE

The JCS process (jcsd) could not load blade bay data for the specified blade.

JCS_BBD_LOCAL_MISMATCH

The blade bay data retrieved for the specified blade does not match the data loaded during the reboot process. This error usually indicates that blade bay data in the JCS Management Module was changed since the last reboot.

JCS_BBD_NOT_FOUND

The blade bay data was not found for the specified blade.

JCS_BBD_NOT_VALID

The blade bay data for the specified blade is invalid.

JCS_BBD_PARSE_ERROR

The blade bay data for the specified blade did not parse correctly.

JCS_BBD_PEER_MISMATCH

The blade bay data retrieved for the specified peer blade does not match the data retrieved for the local blade. This error indicates that blade bay data in the JCS Management Module was not configured properly.

JCS_KERNEL_RSD_LINK_DOWN

The JCS process (jcsd) has disabled kernel RSD communication for the specified reason.

JCS_MM_COMMUNICATION_ERROR

The JCS process (jcsd) could not send an SNMP request to the Management Module because of the indicated error.

JCS_READ_BANDWIDTH_ERROR

The indicated error occurred when attempting to read the current switch bandwidth.

JCS_READ_BBD_ERROR

The indicated error occurred when attempting to read the current blade bay data via a sysctl call.

JCS_SWITCH_COMMUNICATION_ERROR

The JCS process (jcsd) could not send an SNMP request to the indicated Switch Module because of the indicated error.

JSRPD_DAEMONIZE_FAILED

The Juniper Services Redundancy Protocol process (jsrpd) could not create a version of itself to run in the background as a daemon.

JSRPD_EVLIB_EXIT_FAILURE

The Juniper Services Redundancy Protocol process (jsrpd) returned from an event loop, which it should never do.

JSRPD_RG_STATE_CHANGE

The Juniper Services Redundancy Protocol process (JSRPD) detected an event that caused the state of the chassis cluster redundancy group to change due to the reason indicated in the log.

JSRPD_SET_SPU_MON_FAILURE

The Juniper Services Redundancy Protocol process (JSRPD) detected Services Processing Unit (SPU) monitoring failure for a redundancy group.

JSRPD_SOCKET_CREATION_FAILURE

The jsrpd process (jsrpd) could not successfully create a socket.

JSRPD_SOCKET_LISTEN_FAILURE

The Juniper Services Redundancy Protocol process (jsrpd) could not successfully listen on a socket.

JSRPD_SOCKET_RECV_HB_FAILURE

The Juniper Services Redundancy Protocol process (jsrpd) was not successfully received on a socket.

KERNEL.*i2c_s1.*group.*device

Fan tray response error. Error due to the fan tray processing a different task.

KERNEL: rdp retransmit error

Kernel is indicating the no system buffer space is available.

KERNEL:.*cksum.*out of data.*

"/kernel: cksum: out of data" is logged in the system log.

KERNEL:.*jsr_prl_recv_ack_msg.* received PRL ACK message

Non-stop routing replication message acknowledgment received by backup Routing Engine.

KERNEL:.*Voltage Fail Shutdown.*device.*

The ' Voltage Fail Shutdown' message is reported into the system message file if the indicated device in the syslog message has or is about to undergo a reset or due to improper grounding of the FRU causing it to go offline.

KERNEL:.*WRITE_DMA UDMA ICRC error.*

This message is seen when there is hardware fault either on the hard drive or communication between hard drive and kernel or RE and the motherboard.

Kernel:/kernel: pfe_send_failed, err=32

This is an internal message generated by the Kernel. There is a keepalive sent to the PFE to check the status. The kernel missed keepalive for the CFEB because hardware failure.

KERNEL:GENCFG: op 2 (Gencfg Blob) failed.*

Kernel error message generated because it does not have a handler for a certain GENCFG blob message.

KERNEL:general-authentication-service terminated by signal number 11

The "general-authentication-service terminated" message reports that the authentication daemon has crashed and is being restarted. An associated core dump file has also been created on the device.

KERNEL:ifd_request: RTM_ID.*

Some Junos OS daemons were not originally included in a list of processes that can modify an interface definition. These messages are only informational and can be ignored.

KERNEL:parity error detected, fll reinit: mpfe.*

The message indicates that the Packet Forwarding Engine was reset when detecting a parity error in the ASIC.

KERNEL:pfestat_req_receive: request.*

Kernel message regarding PFE statistics counter request.

KERNEL:Process .* has exceeded 85% of RLIMIT_DATA

This message indicates that the virtual memory size of a process’s data-segment area (RLIMIT_DATA) has exceeded its current soft limit.

KERNEL:RT_PFE: RT msg op 1 (PREFIX ADD) failed

When the Routing Protocol Process (rpd) is running out of all available memory, kernel may fail to allocate memory for new prefixes. In this case a message of the following form may appear in the Syslog message file: kernel: RT_PFE: RT msg op 1 (PREFIX ADD) failed, err 6 (No Memory).

KERNEL:unilist found on the rnhlist_deleted_root patnode

When Graceful Routing Engine Switchover (GRES) is enabled this message may be logged by the Master RE's kernel, as it is trying to add a unilist next hop route; however there is already a delete request pending acknowledgement from the Backup RE's kernel. So, the add request is deferred until the delete request is acknowledged. The number printed is the Next Hop Index in the Packet Forwarding Engine.

KERNEL:rdp retransmit error

The kernel is indicating that no system buffer space is available.

KERNEL:RT_PFE: NH IPC failed, err 6 (No Memory)

The kernel is reporting that the Packet Forwarding Engine cannot install or change routing table entries because it is running out of memory.

KERNEL:vlan MAC filter: .* from port .* rejected

If a protocol is not configured on EX but it receives VRRP packets, all those packets will be dropped in kernel with message as ""/kernel: vlan MAC filter: 01:00:5e:00:05: reject"" can be seen in /var/log/messages. This message is seen when packets arrive for all those protocol packets for which EX is not configured/enabled. When RVI is configured on vlan , a copy of all L3 multicast control packets (IEEE well known multicast macs, like OSPF, VRRP, PIM, etc) is sent to the kernel.

KMD_SNMP_PIC_NO_RESPONSE

The indicated PIC did not respond to a request from the key management process (kmd) for Simple Network Management Protocol (SNMP) statistics about IP Security (IPSec) security associations.

L2ALD_IPC_PIPE_WRITE_ERROR

The Layer 2 address learning process (l2ald) could not write to an interprocess communication (IPC) pipe for the indicated reason.

L2ALD_PIP_IFD_READ_RETRY

The Layer 2 address learning process (l2ald) could not read the provide-in-provider interface (pip0) interface from the kernel.

L2CPD_ABORT

The Layer 2 Control Protocol process (l2cpd) terminated because of an internal error.

L2CPD_ASSERT

The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. l2cpd with the indicated executable name and process ID (PID) terminated because the indicated test failed at the indicated line number in the indicated source file. The process created a diagnostic core file for analysis by technical support personnel.

L2CPD_ASSERT_SOFT

The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. l2cpd with the indicated executable name and process ID (PID) terminated because the indicated type of check failed at the indicated line number in the indicated source file. The process continued to run, but created a diagnostic core file for analysis by technical support personnel.

L2CPD_PPM_WRITE_ERROR

The Layer 2 Control Protocol process (l2cpd) could not write a message on the pipe to the periodic packet management process (ppmd).

L2CPD_SCHED_SLIP

The Layer 2 Control Protocol process (l2cpd) delayed an event, such as issuing an adjacency establishment message that was supposed to occur at a particular time. The event did not occur at the right time.

L2CPD_SYSTEM_CALL_FAILED

A system call made by the Layer 2 Control Protocol process (l2cpd) failed.

L2TPD_EVLIB_CREATE_FAILED

The Layer 2 Tunneling Protocol process (l2tpd) could not create a context for handling asynchronous events.

L2TPD_EVLIB_CREATE_FAILED

The Layer 2 Tunneling Protocol process (l2tpd) could not create a context for handling asynchronous events.

L2TPD_SERVER_START_FAILED

The Layer 2 Tunneling Protocol (L2TP) server did not start.

LACPD_DAEMONIZE_FAILED

The Link Aggregation Control Protocol process (lacpd) could not create a version of itself to run in the background as a daemon.

LIBESPTASK_SNMP_CONN_PROG

The indicated error occurred while the process using libesptask was connecting to the SNMP master agent.

LIBESPTASK_SNMP_SOCKOPT_RECVBUF

The process using libesptask could not set the size of the kernel receive buffer, which allows it to accept the largest possible packet from the Simple Network Management Protocol (SNMP) master agent.

LIBESPTASK_SNMP_SOCKOPT_SENDBUF

The process using libesptask could not set the size of the kernel send buffer, which allows it to send the largest possible packet to the Simple Network Management Protocol (SNMP) master agent.

LIBJNX_DEFAULT_IP_ADDR_NOT_SET

A Junos OS process could not retrieve the system default IP address from the kernel because the address is not defined there.

LIBJNX_EVLIB_FAILURE

A Junos OS process called the indicated function in the event library. The function failed for the indicated reason.

LIBJNX_EXEC_SIGNALED

A Junos OS process created a child process to execute the indicated command. The child process received the indicated signal and exited.

LIBJNX_REPLICATE_RCP_ERROR

The rcp command failed during replication.

LIBJNX_SNMP_ENGINE_FILE_FAILURE

A Junos OS process could not perform the indicated operation on the indicated SNMP engine data file.

LIBJNX_SNMP_ENGINE_SCAN_FAILURE

A Junos OS process could not perform the scan operation on the indicated SNMP engine data file.

LIBJNX_SOCKET_FAILURE

Various system processes use Transmission Control Protocol (TCP), User Datagram Protocol (UDP), and Reliable Data Protocol (RDP) sockets. The indicated socket operation failed for the indicated reason.

LIBJSNMP_NS_LOG_EMERG

SNMP errors with LOG_EMERG as severity.

LIBJSNMP_NS_LOG_ERR

SNMP errors with LOG_ERR as severity.

LIBMSPRPC_CLIENT_INIT_FAILED

A Junos OS process (mspinfo) could not establish initialization of the RPC client.

LIBMSPRPC_CLIENT_KCOM_FAILED

A Junos OS process (mspinfo) could not establish initialization of the KCOM subsystem.

LIBMSPRPC_CLIENT_KCOM_NO_IF

A Junos OS process (mspinfo) could not find any configured and active extension-provider interfaces.

LIBMSPRPC_CLIENT_NO_CONNECTION

Remote execution of the command given from the Routing Engine to the PIC failed. The Routing Engine cannot connect to the PIC.

LIBMSPRPC_CLIENT_NO_REPLY

Remote execution of the command given from the Routing Engine to the PIC failed. There was no reply from the PIC.

LIBMSPRPC_CLIENT_PIC_DOWN

Remote execution of the command given from the Routing Engine to the PIC failed. The PIC is down.

LIBMSPRPC_CLIENT_WRONG_OUTPUT

Remote execution of the command given from the Routing Engine to the PIC failed. The PIC returned unexpected output.

LIBSERVICED_CLIENT_CONNECTION

An attempt to establish a client connection failed.

LIBSERVICED_SOCKET_BIND

An attempt to bind a server socket for receiving client requests failed.

LIBSERVICED_SOCKET_PRIVATIZE

An attempt to attach a socket to the management routing instance for communication between the Routing Engine and GGSN-C PICs failed.

LICENSE_EXPIRED

A time-based license for a feature has expired. The feature will remain inactive until a new license is installed.

LICENSE_GRACE_PERIOD_APPROACHING

The grace period for a licensable feature is about to expire. Unless a new license is installed, the feature will become inactive after the grace period expires.

LICENSE_GRACE_PERIOD_EXCEEDED

The grace period for a scale license is about to expire. Unless the scale license is upgraded, the license will scale back to the licensed limit after the grace period expires.

LICENSE_GRACE_PERIOD_EXPIRED

The grace period for a licensable feature has expired. Strict license enforcement will remain active until a new license is installed.

LICENSE_NEARING_EXPIRY

A time-based license for a feature is about to expire. Unless a new license is installed, the feature will become inactive after the license expires.

LICENSE_SOCKET_FAILURE

The indicated process encountered a system error when manipulating a socket.

LLDPD_SYSTEM

A system call made by the Link Layer Discovery Protocol process (LLDPD) failed.

LPDFD_DYN_PDB_OPEN_FAILED

The local policy decision function process (lpdfd) failed to open the profile database.

LPDFD_DYN_REGISTER_FAILED

The local policy decision function process (lpdfd) failed to register with the dynamic configuration subsystem.

LPDFD_DYN_SDB_OPEN_FAILED

The local policy decision function process (lpdfd) failed to open the session database.

LPDFD_PCONN_SERVER

The local policy decision function process (lpdfd) pconn server failed to initialize.

LPDFD_RTSOCK_OPEN_FAILURE

The local policy decision function (LPDF) services process could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error.

MIB2D_REALPATH_FAILURE

When MIB2D is copying the /var/db/dcd.snmp_ix file, it could not resolve its real path.

MIB2D_RTSLIB_READ_FAILURE

A call to the indicated function in the routing socket library failed during the indicated operation on the indicated object.

MIB2D_SNMP_INDEX_ASSIGN

MIB2D cannot assign an SNMP index for each interface.

MIB2D_SNMP_INDEX_DUPLICATE

The first interface name was assigned the same SNMP index as the second interface name.

MIB2D_SNMP_INDEX_UPDATE_STAT

MIB2D cannot get the status of the SNMP index file.

MIB2D_SNMP_INDEX_WRITE

MIB2D cannot write to a file containing all the indices.

NSD_MEMORY_ALLOC_FAILED

The network security process (nsd) could not allocate the indicated number of bytes of memory.

NSD_SEC_NODE_COMP_SYNC_FAILED

One or more subcomponents of the network security process (nsd) failed to synchronize their state when the nsd restarted on secondary mode.

NSTRACED_MEMORY_ALLOC_FAILED

The USP trace process (nstraced) could not allocate the indicated number of bytes of memory.

NSTRACED_SSAMLIB_CALL_FAILED

The indicated error occurred when the usp trace daemon process (nstraced) called a function in the ssamlib library or tried to process a callback from the library.

PFE Crash

Any Packet Forwarding Engine board crash that occurs in conjunction with a system exception message.

PFE: .*ichip_f_check_dest_errors.*

FPC is reporting a bad fabric connection to one or more destinations. Another FPC is likely to be causing the packet corruption.

PFE: .*L2 Cache Single-bit ECC errors.*

PFE component is reporting that L2 Cache Single-bit ECC errors were detected in the last 30 seconds. If problem persists, this is likely to result in a component crash or failure.

PFE: .*new crcerror errors in NLIF.*

Outbound FPC is reporting a corrupt packet received on the Nchip to Lchip interface. Another FPC is likely to be causing the packet corruption.

PFE: ASIC Initialization Error

Any Packet Forwarding Engine ASIC initialization error that occurs in conjunction with a system exception message, such as: router-name fpc5 CMG: Fatal ASIC initialization error, Offlining FPC

PFE: CMRFEB: Fatal HSL2 errors for FPC

A switching board (for example, FEB) is reporting a bad fabric connection to an FPC.

PFE: DFW: jtree cutover failed

The firewall filter configuration cannot be applied due to insufficient amount of contiguous memory on the SRAM.

PFE: Failed to find MC RT_NH entry:.*

Informational message logged when multicast next-hop traffic ages from the switch routing tables.

PFE: HSL2–HSL2 detected fatal error

The FPC detected a fatal HSL2 error.

PFE: I-CHIP New illegal link errors in WO DESRD

Potential ICHIP stream problem possibly due to IFL flooding. Potential match with PR/289104—may need software upgrade.

PFE: I-CHIP New packet errors in WO HDRF, iwo_hdrf_poll_stats

Potential ICHIP stream problem possibly due to IFL flooding. Potential match with PR/289104—may need software upgrade.

PFE: imq_stream_disable_stream

The I-chip wedge issue described in PR 277853, which can lead to packet corruption or packet loss. The Event trigger contains the string: imq_stream_disable_stream.

PFE: JBUS error

An error occurred on the FPC control bus used for packet memory allocation.

PFE: LCHIPnew errors in LSIF

The FPC is reporting LCHIP interface errors.

PFE: mrvl_dfw_log_effuse_status:Firewall rows

The TCAM error messages listed indicate a permanent non-fixable error with TCAM, if they persist after rebooting the EX Switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are not harmless. ACLs will be unreliable on this FPC.

PFE: Multi-bit ECC error

The Packet Forward Engine detected a multi-bit error correcting code (ECC) error in one of the forwarding engine boards.

PFE: Multiple Correctable ECC

The Packet Forward Engine board is reporting multiple correctable ECC memory errors.

PFE: Multiple UnCorrectable ECC

The Packet Forward Engine board is reporting multiple uncorrectable ECC memory errors.

PFE: NFAB(x/y): z new CRC errors detected

Fabric connection to ingress FPC is reporting a bad connection.

PFE: Packet drop in Ichip

The Ichip packet writer drop counter is incrementing, possibly indicating packet drops which may, but not necessarily, be due to a faulty switching board.

PFE: RCHIP: SRAM parity error

SRAM parity error detected on FPC RCHIP.

PFE: Route TCAM rows could not be redirected on device

The TCAM error messages listed indicate a permanent non-fixable error with TCAM, if they persist after rebooting the EX Switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are not harmless. ACLs will be unreliable on this FPC.

PFE: RT: Failed prefix change

These messages indicate that the Routing Engine is trying to delete routes from the Packet Forwarding Engine, but it can't because the routes aren't there. This usually means the Packet Forwarding Engine has run out of memory. For example, if you bring up many BGP peers, the number of routes the Routing Engine can hold may surpass the number the Packet Forwarding Engine can hold. In this case, the Packet Forwarding Engine runs out of memory and can't add the routes. Later, when the Routing Engine tries to remove the routes, the prefix it’s looking for is unknown.

PFE: SDRAM ECC Error

Any Packet Forwarding Engine SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name fpc0 ADPC: detected 1 DDR SDRAM Single-bit ECC errors in the last 30 seconds.

PFE: SHEAF: possible leak

Possible FPC SHEAF memory leak.

PFE: SRAM Parity Error

Any Packet Forwarding Engine SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name ssb CCHIP: %PFE-3: SRAM parity error 0x80000 bank 0x1.

PFE: SRCHIP-SRAM parity error

The FPC SRCHIP has detected an SRAM parity error.

PFE: TOXIC SFP

The TOXIC SFP message is logged when an SFP I2C (the bus via which the router monitors the SFP and updates diagnostic data) transaction fails. Junos then marks the SFP as toxic.

PFE:%PFE- PIO Read error.

The PIO read error could indicate a hardware issue with the PIC.

PFE:.*CCHIP: .*abnormal discard seen.*

Packet Forwarding Engine board is reporting CCHIP abnormal discard errors.

PFE:.*clock error.*

Clock error reported on PFE board.

PFE:.*CRC link error detected for FPC

Errors are a result of HSL CRC errors sent from Switch Fabric to DPC.

PFE:.*DFW: jtree cutover failed.*

Firewall filter configuration cannot be applied due to insufficient amount of contiguous memory on the sram.

PFE:.*HSL2: HSL2 detected fatal error.*

FPC detected fatal HSL2 error.

PFE:.*mrvl_brg_port_stg_cist_init.*

Initialization Warning message pertaining to MSTP/STP/RSTP configured ports for any spanning tree groups shared common IST(CIST).

PFE:.*ICHIP:.* New illegal link errors in WO DESRD.*

Potential ICHIP stream problem possibly due to IFL flooding. Potential match with PR/289104 -- may need software upgrade.

PFE:.*ICHIP:.*New packet errors in WO HDRF, iwo_hdrf_poll_stats.*

Potential ICHIP stream problem possibly due to IFL flooding. Potential match with PR/289104 -- may need software upgrade.

PFE:.*mrvl_dfw_log_effuse_status: Firewall rows.*

The TCAM error messages listed indicate a permanent non-fixable error with TCAM, if they persist after rebooting the EX Switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are not harmless. ACLs will be unreliable on this FPC.

PFE:.*RCHIP.*: SRAM parity error.*

SRAM parity error detected on FPC RCHIP.

PFE:.*RSMON: Resource Category:jtree Instance.*less than LWM limit.*

RSMON is reporting critical jtree memory resource shortage.

PFE:.SFP receive power low warning

SFP receive power low warning.

PFE:COSMAN-FPC allocation of scheduler failed for stream type

The COSMAN-FPC allocation failure event message is generated when a scheduler has to be allocated, but the action results in failure.

PFE:CXGE_SPI42: cxge_spi42_update_errors: snk: pkt end with eop abort

2HX FPGA error The S2HX FPGA is reporting it received an invalid cell. This does not mean the chip caused the error, only that it is reporting it.

PFE:DFPGA got error events on non-zero link in last one second

The "DFPGA got .* error events on non-zero link in last one second" message reports that the associated PIC has sent the stated number of spurious interrupts.

PFE:Errors ucode data error

The "Errors ucode data error" message is logged each time an ASIC fails its periodic code check.

PFE:EZsrhStruct_StatEntry_DoesExist failed

The message is emitted by the interface statistics module. The module is expecting a particular interface to be present, and did not find the data structure for that interface.

PFE:Failed to find MC RT_NH entry:.*

Informational message logged when multicast next-hop traffic ages from the switch routing tables.

PFE:Fatal Error Encountered by .*

The "Fatal Error Encountered by" message reports that the specified hardware is not able to handle some transit traffic internally.

PFE:HSR.Too many crc errors

The "HSR: Too many crc errors" message reports that the indicated part in the message has gone into link error and may require reseating and/or replacement. It may also indicate a false alarm thrown by the SIB/FPC.

PFE:ICHIP(.) Queue Wedge detected in physical queue

The "Queue Wedge detected in physical queue" message indicates that there was traffic queued on a specific interface queue that was being dropped.

PFE:ICHIP(.) Queued traffic in physical queue .* not transmitted

This message reports that ICHIP Queued traffic in a physical queue is not being transmitted. When this condition is seen, the router will automatically change the COS configuration for the queue in order to force the queue to empty. The COS parameters will then be restored again after one second.

PFE:ICHIP IMQ: error sid detected

The "error sid .* detected" message is reporting that the Packet Forwarding Engine (PFE) is receiving instuctions from the IMQ (Inbound Message Queuing) to forward data to a SID (system ID) that is either a duplicate or that does not exist. The ICHIP is only reporting the condition. It is not the cause of the issue.

PFE:ICHIP(.*)_REG_ERR:.*

An ICHIP(.*)_REG_ERR message occurs when an ICHIP reports an issue detected on an incoming fabric stream. The ICHIP is only reporting the event, and is not the source of the fabric issue.

PFE:LUCHIP Wedge Detected, Active Zones

The "Wedge Detected, Active Zones" message reports transit traffic congestion on the associated LU chip on the FPC listed in the syslog message.

PFE:MQCHIP timed out waiting for phy_stream

The "timed out waiting for phy_stream" syslog message reports an error found by the MQ chip in the traffic stream. Most likely the error occurred elsewhere, as the MQ chip is only detecting the issue.

PFE:MQchip.*XE.*Throttle: Last.*seconds have seen interrupt throttling at

The MQ chip has limited the number of interrupts being triggered on the PFE.

PFE:MQCHIP(.) FI Reorder cell timeout

The "FI Reorder cell timeout" message reports there was a packet drop in fabric traffic.

PFE:PIO error indicated

The "PIC <number> PIO error indicated " message may report that the indicated PIC had connectivity issues or has experienced a hardware failure.

PFE:phy_BCM8726_read_i2c: pumaj phy eeprom read failed

When the "phy_BCM8747_read_i2c: phy eeprom read failed" log message is seen on EX 8200 switches, the system missed a read from the EEPROM.

PFE:port command handler failed processing cmd

This message is seen when there is an error with incorrect polling status for SFP on copper interfaces.

PFE:PPE PPE HW Fault Trap

A trap occurred when microcode attempted to interpret data past the end of the packet. This can also been seen in connection with this syslog message: fpc1 LU 1 PPE_12 Errors lmem addr error

PFE:Reflective Relay set Failed

Reflective Relay failed to be enabled on the specified interface.

PFE:Route TCAM rows could not be redirected on device.*

The TCAM error messages listed indicate a permanent non-fixable error with TCAM, if they persist after rebooting the EX Switch or Virtual Chassis (VC). These errors are TCAM hardware issues on this FPC and are not harmless. ACLs will be unreliable on this FPC.

PFE:sntl_f_check_dest_errors: Fabric request time out for plane

The "sntl_f_check_dest_errors: Fabric request time out for plane" message is logged when an issue with a fabric connection is detected. The message reports the hardware that detected the issue, not the hardware that produced it.

PFE:SIB_STATE_ONLINE-> SIB_STATE_OFFLINE_ACK_WAIT

"When a ""state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT"" event occurs, a message similar to one of the following is reported:

sfc0-spmb0 CMGSIB: SIB #14 state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT sfc0-spmb0 CMGSIB: %PFE-6: SIB #1 state transition SIB_STATE_ONLINE -> SIB_STATE_OFFLINE_ACK_WAIT

This message may be associated with one or more of the following messages in the syslog output:

CMGSIB: SIB #0 state transition SIB_STATE_OFFLINE_ACK_WAIT -> SIB_STATE_OFFLINE CMGSIB: cmg_sib_button_action(): 0 CMGSIB: Offline button request for SIB 0 CMGSIB: %PFE-3: SIB#1 voltage outside tolerance! spmb0 CMGSIB: SIB#0 voltage outside tolerance for channel: 10! sfc0-spmb0 CMGSIB: %PFE-3: Taking SIB#1 offline! chassisd[3247]: CHASSISD_FRU_OFFLINE_NOTICE: Taking SIB 1 offline: Offlined by cli command chassisd[2906]: CHASSISD_SNMP_TRAP10: SNMP trap generated: FRU power off (jnxFruContentsIndex 15, jnxFruL1Index 22, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName SFC0 SIB F2S 1/2, jnxFruType 9, jnxFruSlot 21, jnxFruOfflineReason 7, jnxFruLastPowerOff 423594357, jnxFruLastPowerOn 159058) When a SIB goes offline, this can trigger an alarm on the system."

PFE:SONN errors

The "SONN errors" message is logged periodically when the FPC looses track of notification cell traffic, and reports the number of frames dropped.

PFE:SRCHIP(.): RKME int_status 10x100

RKME is a key match engine located in the FPC SRCHIP/RCHIP hardware. The RKME engine received the error interrupt shown.

PFE_NH_RESOLVE_THROTTLED

The Packet Forwarding Engine throttled next-hop resolution requests from the indicated interface, because the high number of requests might constitute an attempted denial-of-service (DoS) attack. Examples of events that generate next-hop resolution requests include an attempt to forward a packet without an Address Resolution Protocol (ARP) entry and receiving a multicast data packet with no matching route. Normally, the Packet Forwarding Engine forwards the requests to the Routing Engine.

PFE_PACKET_DISCARD_ERROR

The counter for tag /pfe-hardware-statistics/fabric-discard from the junoscript call get-pfe-statistics (show pfe statistics) incremented.

PIC Crash

Any PIC crash that occurs in conjunction with a system exception message.

PPMD_ASSERT_SOFT

The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As ppmd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. ppmd created a diagnostic core file for analysis by technical support personnel and continued to run.

PPMD_READ_ERROR

The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As ppmd with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. ppmd created a diagnostic core file for analysis by technical support personnel and continued to run.

problem-event-ichipfcheck

The FPC is reporting a bad fabric connection to one or more destinations. Another FPC is likely to be causing the packet corruption.

problem-event-jbuserror

An error occurred on the FPC control bus used for packet memory allocation.

problem-event-l2cacheerror

The Packet Forwarding Engine component is reporting that Layer 2 Cache Single-bit ECC errors were detected in the last 30 seconds. If the problem persists, this situation is likely to result in a component crash or failure.

problem-event-lchipcrc

The outbound FPC is reporting a corrupt packet received on the Nchip-to-Lchip interface. Another FPC is likely to be causing the packet corruption.

problem-event-nfabcrcerror

The fabric connection to the ingress FPC is reporting a bad connection.

RDD_EVLIB_CREATE_FAILURE

The redundant interfaces process (rdd) could not create a context used for handling all asynchronous events (such as timers and message availability).

Reboot reason(s): 0x2: watchdog

RE watchdog timeout event. Related to PSN-2008-07-017 and PR/297313. Event will be triggered by string: Reboot reason(s): 0x2: watchdog.

RMON_EVENT_fpc_high_buffer_utilization

Remote monitoring event reporting high buffer utilization on FPC.

RMON_EVENT_fpc_high_cpu_utilization

High CPU utilization on FPC.

RMON_EVENT_fpc_high_heap_utilization

Remote monitoring event reporting high heap utilization on FPC.

RPD_ABORT

The routing protocol process (rpd) terminated because of an internal error.

RPD_ACTIVE_TERMINATE

After receiving multiple termination requests, the routing protocol process (rpd) exited without performing the indicated cleanup tasks.

RPD_ASSERT

The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, causing the instance of rpd that was using the indicated binary and had the indicated process ID (PID) to terminate. The process created a diagnostic core dump for analysis by technical support personnel.

RPD_ASSERT_SOFT

The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, but the instance of rpd that was using the indicated binary and had the indicated process ID (PID) continued running. The process created a diagnostic core dump for analysis by technical support personnel.

RPD_BGP_NEIGHBOR_STATE_CHANGED

During the BGP negotiation with the local router, the state of the indicated BGP neighbor (peer) changed as indicated. The ESTABLISHED state is the final state in the neighbor negotiation.

RPD_DYN_CFG_BAD_REQ_OPCODE

The routing protocol process (rpd) received a dynamic configuration request with an unexpected operation code.

RPD_DYN_CFG_BUSY_SIGNAL_FAILED

The routing protocol process (rpd) failed to notify dynamic configuration clients about its availability to process dynamic configuration requests.

RPD_DYN_CFG_GET_PROF_NAME_FAILED

The routing protocol process (rpd) tried to get the profile name from the session snapshot and failed.

RPD_DYN_CFG_GET_PROFILE_FAILED

The routing protocol process (rpd) tried to load a profile from the database and failed.

RPD_DYN_CFG_GET_SES_STATE_FAILED

The routing protocol process (rpd) failed to get the session state from the session snapshot.

RPD_DYN_CFG_GET_SNAPSHOT_FAILED

The routing protocol process (rpd) tried to load client session data from the database and failed.

RPD_DYN_CFG_PDB_CLOSE_FAILED

The routing protocol process (rpd) tried to close the profile database and failed.

RPD_DYN_CFG_PDB_OPEN_FAILED

The routing protocol process (rpd) tried to open the profile database and failed.

RPD_DYN_CFG_PROCESSING_FAILED

The routing protocol process (rpd) tried to process dynamic configuration and failed.

RPD_DYN_CFG_REGISTER_FAILED

The routing protocol process (rpd) tried to register with the dynamic configuration subsystem and failed.

RPD_DYN_CFG_REQUEST_ACK_FAILED

The routing protocol process (rpd) tried to ACK a dynamic configuration request and failed.

RPD_DYN_CFG_SCHEMA_OPEN_FAILED

The routing protocol process (rpd) tried to open the configuration schema and failed.

RPD_DYN_CFG_SDB_CLOSE_FAILED

The routing protocol process (rpd) tried to close the session database and failed.

RPD_DYN_CFG_SDB_OPEN_FAILED

The routing protocol process (rpd) tried to open the session database and failed.

RPD_DYN_CFG_SES_RECOVERY_FAILED

The routing protocol process (rpd) tried to recover a session and failed.

RPD_ISIS_ADJDOWN

An IS-IS adjacency with the indicated neighboring router was terminated. The local router will no longer exchange routing information with, or direct traffic to, the neighboring router.

RPD_ISIS_LSPCKSUM

The indicated IS-IS informational link-state PDU (LSP) failed an internal checksum validity test, indicating that it was corrupted.

RPD_ISIS_OVERLOAD

The IS-IS link-state database is full and no additional memory can be allocated for it.

RPD_KRT_KERNEL_BAD_ROUTE

As it restarted, the routing protocol process (rpd) could not process a route obtained from the kernel because the route contained references to objects that are no longer valid.

RPD_KRT_Q_RETRIES

The routing protocol process (rpd) attempted to update the kernel for the indicated times and failed. It will continue retrying.

RPD_LMP_UNEXPECTED_OPCODE

The routing protocol process (rpd) received the indicated type of message, which had the indicated invalid operation code.

RPD_OS_MEMHIGH

The routing protocol process (rpd) is using the indicated amount and percentage of Routing Engine memory, which is considered excessive.

RPD_OSPF_NBRDOWN

An OSPF adjacency with the indicated neighboring router was terminated. The local router will no longer exchange routing information with, or direct traffic to, the neighboring router.

RPD_RSVP_NBRDOWN

The RSVP neighbor to the indicated address was terminated.

RPD_RT_ERROR

A route in the routing table was found to be in an unrecoverable error state.

RPD_TASK_FORK

The routing protocol process failed to create the indicated child process.

RT_SCREEN_TCP

A TCP attack category.

RT_SCREEN_UDP

A UDP attack category.

RTLOGD_DAEMONIZE_FAILED

The JSR log daemon could not create a version of itself to run in the background as a daemon.

RTLOGD_EVLIB_FAILURE

The JSR log daemon called the indicated event library function. The function failed with the indicated error.

RTLOGD_GET_TNP_ADDRESS_FAILED

JSR log daemon failed to determine local TNP address used to receive JSR log.

RTLOGD_LOG_BIND_ERROR

The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to connect to the forwarder.

RTLOGD_LOG_READ_ENABLE_ERROR

The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to enable the reading of the JSR log from the forwarder.

RTLOGD_LOG_READ_ERROR

The JSR log daemon relayed the JSR logs from the dataplane to the system event daemon for logging. The JSR log daemon failed to read JSR logs for the indicated reason.

RTPERF_CPU_THRESHOLD_EXCEEDED

The Packet Forwarding Engine CPU threshold has been exceeded.

SAVAL_RTSOCK_FAILURE

The MAC SA Validate system process (jsavald) experienced the indicated error with a routing socket.

SDXD_DAEMONIZE_FAIL

The Service Deployment System process (sdxd) could not create a version of itself to run in the background as a daemon.

SERVICED_CLIENT_DISCONNECTED

The remote client closed the connection or stopped responding.

SERVICED_CLIENT_ERROR

An I/O error caused the termination of a connection with an interface client.

SERVICED_COMMAND_FAILED

An error caused a command being executed on an interface client to be cancelled.

SERVICED_CONNECTION_ERROR

The remote client closed the connection when data was expected.

SERVICED_EVENT_FAILED

The services PICs process (serviced) could not continue processing a task because a call to a function in the event library failed.

SERVICED_INIT_FAILED

One of the steps in the initialization sequence for the services PICs process (serviced) failed.

SERVICED_INTERNAL_INCONSISTENCY

An internal consistency check failed due to a mismatch between expected and received values for the specified object.

SERVICED_MALLOC_FAILURE

The services PICs process (serviced) could not allocate the number of bytes needed to hold the indicated object.

SERVICED_NETWORK_FAILURE

An attempt to use the indicated network library call failed with an error.

SERVICED_PID_FILE_LOCK

As a part of normal startup, the services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not lock the file.

SERVICED_PID_FILE_UPDATE

As a part of normal startup, the services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not write to the file.

SERVICED_RTSOCK_SEQUENCE

The services PICs process (serviced) encountered a sequence error while receiving messages from the routing socket library.

SERVICED_SIGNAL_HANDLER

As a part of normal functioning, the services PICs process (serviced) attempted to initialize a signal-handling function. Part of the initialization failed with an error.

SERVICED_SOCKET_CREATE

An attempt by the services PICs process (serviced) to create a new socket for communication with an interface client failed with an error.

SERVICED_SOCKET_IO

A call to a socket library function indicated that an error occurred while attempting to perform I/O.

SERVICED_SOCKET_OPTION

An attempt to set an option on a socket failed

SERVICED_STDLIB_FAILURE

The value returned by a call to a library function indicated that an error occurred.

SNMP_PATRICIA_ERROR

A call to a Patricia tree library function returns an error.

SNMP_RTSLIB_FAILURE

A call to the indicated function in the routing socket library failed with the indicated error

SNMPD_FILE_FAILURE

The Simple Network Management Protocol (SNMP) agent process (snmpd) could not access the indicated file.

SNMPD_RMONFILE_FAILURE

The indicated operation failed on the indicated remote monitoring (RMON) data file.

SNMPD_SEND_FAILURE

The Simple Network Management Protocol (SNMP) agent process (snmpd) could not send either a protocol data unit (PDU) to the User Datagram Protocol (UDP) or a message to a subagent.

SNMPD_SOCKET_FATAL_FAILURE

The Simple Network Management Protocol (SNMP) agent process (snmpd) uses sockets for communication with subagents. The process exited after a socket operation, such as creation or removal, failed.

SNMPD_SUBAGENT_NO_RESOURCES

The Simple Network Management Protocol (SNMP) agent process (snmpd) uses certain resources for communication with subagents. However, the resources were not available for communication with the indicated subagent.

SPD_DAEMONIZE_FAILED

The adaptive services process (spd) could not create a version of itself to run in the background as a daemon.

SPD_EVLIB_CREATE_FAILURE

The adaptive services process (spd) could not create a context used for handling all asynchronous events (such as timers and message availability).

SPD_GEN_NUM_FAIL

The adaptive services process (spd) attempted to initialize the generation-number for the service sets. However, the memory allocation failed.

SYSTEM.*SFP receive power low warning .*

SFP receive power low warning.

SYSTEM: Alarm set: Temp Too Warm

The system is indicating that the sensor on an EX FPC is exceeding the temperature threshold.

SYSTEM: Keepalive timeout of *. Assuming RE mastership.

The backup Routing Engine assumed mastership due to an Routing Engine keepalive timeout.

SYSTEM: SCHED: Thread.*ran for.*without yielding

"Scheduler Oinker" messages seen on console at various instances with various mPIM combinations.

SYSTEM: writing kernel

A kernel crash event. A writing kernel message is captured after the router reboots.

SYSTEM:.*cm_read_i2c errno is 5.*

The chassis manager event message results from an error in calculating the DC power budget for POE interfaces.

SYSTEM:.*dcd.* unknown encaps_ohead; dev vlan, encaps .* flags.*

Informational message generated by dcd deamon in syslog when certain protocols and vlans are configured (e.g., MSTI, VRRP).

SYSTEM:.*snp_igmp_io_flood: relay failed.*

This message indicates that the device is flooding IGMP unknown packet back on the same port that it was received on.

SYSTEM:Adjacency Lost

The message "Action Syslog on .* [adjacency-loss]: :Adjacency Lost" is reported into the system message to indicate the occurrence of a link-fault event i.e. Link Adjacency Lost.

SYSTEM:Alarm set Host ECC single bit parity error

The "ECC single bit parity error" message reports that a correctable single bit error was detected once on the designated platform.

SYSTEM:cannot perform nh operation ADDANDGET

When exporting local OSPF P2P LAN prefixes using rib groups, an error message can be logged containing the ADDANDGET keyword.

SYSTEM:cm_ff_ifd_disable: fast failover disabled

The chassism process could not forward traffic as expected.

SYSTEM:Frame Error crossed threshold

The message "Action Syslog on .* [frame-error-event]: :Frame Error crossed threshold .* " is reported into the system message to indicate the occurrence of a link-fault event i.e. Errored Frame Event.

SYSTEM:Loss of communication with Backup RE

The Loss of communication with Backup RE message is logged each time the Master Routing Engine detects loss of keepalives being sent from the Backup Routing Engine.

TASK_OS_MEMHIGH

The process is using the indicated amount and percentage of Routing Engine memory, which is considered excessive.

TASK_SYSTEM

A system call made by this process failed.

TFTPD_RECVCOMPLETE_INFO

The TFTP process (tnp.tftpd) received the last portion of a transmitted file. This message records the number of blocks received, the block size used, and the name of the file to which the data was written.

UI_DBASE_REBUILD_FAILED

The management process (mgd) could not rebuild the configuration database file.

UI_DBASE_REBUILD_SCHEMA_FAILED

The management process (mgd) could not rebuild the schema for the configuration database.

UI_DBASE_REOPEN_FAILED

After rebuilding the schema file for the configuration database, the management process (mgd) closes the file and reopens it in read-only mode to prevent corruption. It could not reopen the file.

UI_SCHEMA_SEQUENCE_ERROR

The Junos OS user interface schema file records all CLI commands and configuration statements available in the Junos operating system. The management process (mgd) rebuilds the schema as necessary to be compatible with the Junos OS software installed on the device. A sequence number in the schema acts as a checksum that represents its content and format. A Junos OS process attempted to access the schema but determined that the schema's sequence number means that it is incompatible with the process.

UTMD_MALLOC_FAILURE

The example process (utmd) could not allocate memory for a resource, possibly due to a lack of memory.

UTMD_SSAMLIB_FAILURE

The example process (utmd) encountered an error while calling a function or from a callback of the ssamlib library.

VCCPD_PROTOCOL_LSPCKSUM

The indicated vccpd link-state PDU (LSP) failed an internal checksum validity test, implying that it was corrupted.

VCCPD_PROTOCOL_OVERLOAD

The vccpd link-state database is full and no additional memory can be allocated for it.

VRRPD_MISSING_VIP

The indicated interface received a Virtual Routing Redundancy protocol (VRRP) packet for the indicated VRRP group in which the indicated Virtual IP address was missing.

WEB_ALLOCATE

The Web management process (httpd) could not allocate the indicated amount of memory, for the indicated reason.

WEB_MEMORY_ALLOC

The Web management process (httpd) could not allocate the indicated number of bytes of memory, for the indicated reason.

WEB_MGD_LISTEN_ERROR

The Web management process (httpd) could not open the mgd listening socket.

WEB_SOCKET

The Web management process (httpd) could not create a socket, for the indicated reason.

WEBFILTER_CACHE_NOT_ENABLED

The category cache Web filter failed to enable.

WEBFILTER_REQUEST_NOT_CHECKED

The Web filtering failed to check a Web request.