join-timer (MVRP)
Syntax
join-timer milliseconds;
Hierarchy Level
[edit logical-systems logical-system-name protocols mvrp], [edit logical-systems logical-system-name routing-instances routing-instance-name protocols mvrp interface (all | interface-name)] (for virtual switch instance type), [edit logical-systems logical-system-name routing-instances routing-instance-name protocols mvrp] (for virtual switch instance type), [edit logical-systems logical-system-name protocols mvrp interface (all | interface-name)],
[edit protocols mvrp interface (all | interface-name)]
[edit routing-instances routing-instance-name protocols mvrp] (for virtual switch instance type), [edit routing-instances routing-instance-name protocols mvrp interface (all | interface-name)] (for virtual switch instance type)
Description
Konfigurieren Sie die maximale Anzahl von Millisekundenschnittstellen, die warten müssen, bevor mehrere VLAN Registration Protocol (MVRP)-Protokolldateneinheiten (PDUs) gesendet werden.
Beibehalten der Standardzeiteinstellungen, es sei denn, es gibt einen zwingenden Grund, die Einstellungen zu ändern. Das Ändern von Timern an unangemessene Werte kann zu einem Ungleichgewicht im Betrieb von MVRP führen.
Default
200 Millisekunden
Options
milliseconds
– Intervall, das die Schnittstelle warten muss, bevor MVRP-PDUs gesendet werden (zwischen 100 Millisekunden und 500 Millisekunden). Beibehalten der Standardzeiteinstellungen, es sei denn, es gibt einen zwingenden Grund, die Einstellungen zu ändern. Das Ändern von Timern an unangemessene Werte kann zu einem Ungleichgewicht im Betrieb von MVRP führen.
Required Privilege Level
Routing: Um diese Anweisung in der Konfiguration anzuzeigen.Routing-Control: Um diese Anweisung der Konfiguration hinzuzufügen.
Release Information
Erklärung eingeführt in Junos OS Version 10.0.