验证电源配置和使用情况
目的
在支持此功能的设备上验证:
电源冗余和线卡优先级设置
支持 PoE 的线卡的 PoE 功率预算
是否满足 N+1 或 N+N 功率要求
交换机是否有足够的电量来安装新的线卡或 N+N 配置
行动
输入以下命令:
user@switch> show chassis power-budget-statistics
示例输出:
PSU 0 (EX6200-PWR-AC2500) : 2500 W Online
PSU 1 (EX6200-PWR-AC2500) : 2500 W Online
PSU 2 (EX6200-PWR-AC2500) : 2500 W Online
PSU 3 (EX6200-PWR-AC2500) : 2500 W Online
Total Power supplied by all Online PSUs : 10000 W
Power Redundancy Configuration : N+1
Power Reserved for the Chassis : 500 W
Fan Tray Statistics Base power Power Used
FTC 0 : 300 W 43.04 W
FPC Statistics Base power Power Used PoE power Priority
FPC 1 (EX6200-48P) : 220 W 49.47 W 1440 W 1
FPC 2 (EX6200-48P) : 220 W 47.20 W 800 W 2
FPC 3 (EX6200-48P) : 220 W 1493.57 W 1440 W 0
FPC 4 (EX6200-SRE64-4XS) : 100 W 51.38 W 0 W 0
FPC 5 (EX6200-SRE64-4XS) : 100 W 50.28 W 0 W 0
FPC 6 (EX6200-48P) : 220 W 49.38 W 800 W 6
FPC 8 (EX6200-48P) : 220 W 61.41 W 1440 W 9
FPC 9 (EX6200-48T) : 150 W 12.49 W 0 W 9
Total (non-PoE) Power allocated : 1750 W
Total Power allocated for PoE : 5920 W
Power Available (Redundant case) : 5750 W
Total Power Available : 2515 W
意义
输出示例 — 联机电源总共可为交换机提供 10,000 W 的功率。该交换机配置 N为 +1 冗余,这意味着可以提供 7500 W 的冗余电源。“ 可用功率(冗余情况) ”字段显示交换机满足 N+1 功率要求,另有 5750 W 可用功率。此值的计算方法是从冗余功率 (7500 W) 中减去除 PoE 功率分配以外的所有功率分配。
交换机上的可用总功率为 2515 W。该值的计算方法是从总功率 (10,000 W) 中减去所有功率分配,包括 PoE 功率分配。在配备 PoE 线卡的交换机上,如果 可用总功率 为 0,则可能不会为部分或全部 PoE 线卡分配其配置的 PoE 功率预算,这意味着部分或全部 PoE 端口的电源可能被禁用。
线卡的电源优先级顺序(从最高优先级线卡到最低优先级线卡)为 4、5、3、1、2、6、8、9。插槽 4 和 5 包含交换机交换矩阵和路由引擎 (SRE) 模块,始终具有最高优先级,即使编号较低的插槽(如本例中的插槽 3)的优先级为 0 也是如此。如果两个或多个 2500 W 电源发生故障,电源管理将按以下顺序移除或减少 PoE 线卡中的 PoE 功率分配,以平衡功率预算:8、6、2、1 和 3。
风扇托架和线卡的“ 已用功率 ”值显示执行命令时这些组件的实际功耗。这些值仅供参考;电源管理使用分配的功率,该功率基于组件可能消耗的最大功率,而不是实际消耗的功率来确定其功率预算。