show chassis environment routing-engine
语法
show chassis environment routing-engine <slot>
语法(TX 矩阵路由器)
show chassis environment routing-engine <lcc number | scc> <slot>
语法(TX Matrix Plus 路由器)
show chassis environment routing-engine <lcc number | sfc number> <slot>
语法(MX104、MX2010、MX2020、MX10003、MX204 和 MX2008 通用路由平台)
show chassis environment routing-engine <slot> <satellite [fpc-slot slot-id |device-alias alias-name]
语法(MX 系列和 PTX 系列设备)
show chassis environment routing-engine <slot> <all-members> <local> <member member-id>
语法(QFX 系列和 OCX 系列)
show chassis environment routing-engine interconnect-device name
语法(EX9251 和 EX9253 交换机;ACX500、ACX5048 和 ACX5096 路由器)
show chassis environment routing-engine
描述
显示路由引擎环境状态信息。
选项
none | 显示有关所有路由引擎的环境信息。对于 TX Matrix 路由器,显示有关 TX Matrix 路由器及其连接的 T640 路由器上所有路由引擎的环境信息。对于 TX Matrix Plus 路由器,显示有关 TX Matrix Plus 路由器及其连接的路由器上所有路由引擎的环境信息。 |
all-members | (仅限 MX 系列路由器)(可选)显示有关虚拟机箱配置中所有成员路由器中的路由引擎的环境信息。 |
interconnect-device name | (仅限 QFabric 系统)(可选)显示有关互连设备路由引擎的环境信息。 |
lcc number | —(仅限 TX Matrix 路由器和 TX Matrix Plus 路由器)(可选)线卡机箱编号。 根据 number LCC 配置替换为以下值:
|
local | (仅限 MX 系列路由器)(可选)显示有关本地虚拟机箱成员中的路由引擎的环境信息。 |
member member-id | (仅限 MX 系列路由器)(可选)显示有关虚拟机箱配置中指定成员中的路由引擎的环境信息。替换为 member-id 值 0 或 1。 |
satellite [fpc-slot slot-id | device-alias alias-name] | (仅限 Junos Fusion)(可选)显示 Junos Fusion 中指定卫星设备的环境信息,如果未指定卫星设备,则显示 Junos Fusion 中所有卫星设备的环境信息。 |
scc | (仅限 TX Matrix 路由器)(可选)显示有关 TX Matrix 路由器(交换卡机箱)中路由引擎的环境信息。 |
sfc | (仅限 TX Matrix Plus 路由器)(可选)显示有关 TX Matrix Plus 路由器(或交换机结构机箱)中路由引擎的环境信息。 |
slot | (可选)显示有关单个路由引擎的环境信息。在 M10i、M20、M40e、M120、M160、M320、MX 系列、MX104 路由器、MX2010 路由器、MX2020 路由器、MX2008 路由器和 T 系列路由器上,将替换为 slot 0 或 1。在 M5、M7i、M10 和 M40 路由器上,替换为 slot 0。在 EX3200 和 EX4200 独立交换机上,替换为 slot 0。在采用虚拟机箱配置的 EX4200 交换机以及 EX8208 和 EX8216 交换机上,将替换为 slot 0 或 1。在 QFX3500 和 QFX5700 上,只有一个路由引擎,因此您无需指定插槽号。在 PTX 系列数据包传输路由器上,替换为 slot 0 或 1。 |
所需权限级别
视图
输出字段
表 1 列出了命令 show chassis environment routing-engine
的输出字段。输出字段按其出现的大致顺序列出。
字段名称 |
字段说明 |
---|---|
路由引擎 slot 状态 |
路由引擎插槽编号:0 或 1。 |
状态 |
路由引擎的状态:
|
温度 |
流过路由引擎的空气温度 |
中央处理器温度 |
(仅限 PTX 系列和 T4000 核心路由器)流过路由引擎 CPU 的空气温度。 |
示例输出
- 显示机箱环境路由引擎(非冗余)
- 显示机箱环境路由引擎(冗余)
- 显示机箱环境路由引擎 (MX150)
- show chassis environment routing-engine(MX104 路由器)
- show chassis environment routing-engine(MX2010 路由器)
- 显示机箱环境路由引擎(MX2020 路由器)
- show chassis environment routing-engine(MX2008 路由器)
- show chassis environment routing-engine(TX Matrix Plus 路由器)
- show chassis environment 路由引擎(T4000 核心路由器)
- show chassis environment 路由引擎(QFX 系列和 OCX 系列)
- 显示机箱环境路由引擎互连设备(QFabric 系统)
- show chassis environment 路由引擎(PTX5000 数据包传输路由器)
- 显示机箱环境路由引擎(PTX10008路由器)
- 显示机箱环境路由引擎(PTX10016路由器)
- 显示机箱环境路由引擎(ACX5048 和ACX5096路由器)
- show chassis environment 路由引擎(ACX500 路由器)
显示机箱环境路由引擎(非冗余)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 27 degrees C / 80 degrees
显示机箱环境路由引擎(冗余)
user@host> show chassis environment routing-engine Route Engine 0 status: State: Online Master Temperature: 26 degrees C / 78 degrees F Route Engine 1 status: State: Online Standby Temperature: 26 degrees C / 78 degrees F
显示机箱环境路由引擎 (MX150)
user@ host >show chassis environment routing-engine Routing Engine 0 status: State Online Master CPU Temperature 42 degrees C / 107 degrees F
show chassis environment routing-engine(MX104 路由器)
user@ host >show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 34 degrees C / 93 degrees F CPU Temperature 43 degrees C / 109 degrees F Routing Engine 1 status: State Online Standby Temperature 33 degrees C / 91 degrees F CPU Temperature 39 degrees C / 102 degrees F
show chassis environment routing-engine(MX2010 路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 37 degrees C / 98 degrees F CPU Temperature 37 degrees C / 98 degrees F Routing Engine 1 status: State Online Standby Temperature 35 degrees C / 95 degrees F CPU Temperature 34 degrees C / 93 degrees F
显示机箱环境路由引擎(MX2020 路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 35 degrees C / 95 degrees F CPU Temperature 34 degrees C / 93 degrees F Routing Engine 1 status: State Online Standby Temperature 44 degrees C / 111 degrees F CPU Temperature 43 degrees C / 109 degrees F
show chassis environment routing-engine(MX2008 路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master CPU Temperature 75 degrees C / 167 degrees F Routing Engine 1 status: State Online Standby CPU Temperature 47 degrees C / 116 degrees F
show chassis environment routing-engine(TX Matrix Plus 路由器)
user@host> show chassis environment routing-engine sfc0-re0: -------------------------------------------------------------------------- Routing Engine 0 status: State Online Master Temperature 26 degrees C / 78 degrees F Routing Engine 1 status: State Online Standby Temperature 28 degrees C / 82 degrees F lcc0-re0: -------------------------------------------------------------------------- Routing Engine 0 status: State Online Master Temperature 30 degrees C / 86 degrees F Routing Engine 1 status: State Online Standby Temperature 29 degrees C / 84 degrees F
show chassis environment 路由引擎(T4000 核心路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 33 degrees C / 91 degrees F CPU Temperature 50 degrees C / 122 degrees F Routing Engine 1 status: State Online Standby Temperature 33 degrees C / 91 degrees F CPU Temperature 46 degrees C / 114 degrees F
show chassis environment 路由引擎(QFX 系列和 OCX 系列)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master CPU Temperature 42 degrees C / 107 degrees F Routing Engine 1 status: State Online Standby CPU Temperature 34 degrees C / 93 degrees F
显示机箱环境路由引擎互连设备(QFabric 系统)
user@switch> show chassis environment routing-engine interconnect-device interconnect1 routing-engine interconnect-device interconnect1 Routing Engine 0 status: State Online Standby Temperature 52 degrees C / 125 degrees F Routing Engine 1 status: State Online Master Temperature 57 degrees C / 134 degrees F
show chassis environment 路由引擎(PTX5000 数据包传输路由器)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 55 degrees C / 131 degrees F CPU Temperature 66 degrees C / 150 degrees F Routing Engine 1 status: State Online Standby Temperature 52 degrees C / 125 degrees F CPU Temperature 64 degrees C / 147 degrees F
显示机箱环境路由引擎(PTX10008路由器)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master CPU Temperature 40 degrees C / 104 degrees F Routing Engine 1 status: State Online Standby CPU Temperature 40 degrees C / 104 degrees F
显示机箱环境路由引擎(PTX10016路由器)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master CPU Temperature 33 degrees C / 91 degrees F Routing Engine 1 status: State Online Standby CPU Temperature 38 degrees C / 100 degrees F
显示机箱环境路由引擎(ACX5048 和ACX5096路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 33 degrees C / 91 degrees F
show chassis environment 路由引擎(ACX500 路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 54 degrees C / 129 degrees F
示例输出
- 显示机箱环境路由引擎 (PTX5000 (RE-PTX-X8-64G), MX240 (RE-S-X6-64G), MX480 (RE-S-X6-64G), MX960 (RE-S-X6-64G), MX2010 (RE-MX2K-X8-64G), MX2020 (RE-MX2K-X8-64G)
- show chassis environment 路由引擎(MX204 路由器)
- 显示机箱环境路由引擎(MX10008路由器)
- 显示机箱环境路由引擎(EX9251 交换机)
- show chassis environment 路由引擎(EX9253 交换机)
显示机箱环境路由引擎 (PTX5000 (RE-PTX-X8-64G), MX240 (RE-S-X6-64G), MX480 (RE-S-X6-64G), MX960 (RE-S-X6-64G), MX2010 (RE-MX2K-X8-64G), MX2020 (RE-MX2K-X8-64G)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 37 degrees C / 98 degrees F CPU Temperature 52 degrees C / 125 degrees F Routing Engine 1 status: State Online Standby Temperature 37 degrees C / 98 degrees F CPU Temperature 51 degrees C / 123 degrees F
show chassis environment 路由引擎(MX204 路由器)
user@host> show chassis environment routing-engine Routing Engine 0 status: State Online Master
显示机箱环境路由引擎(MX10008路由器)
Routing Engine 0 status: State Online Master CPU Temperature 41 degrees C / 105 degrees F Routing Engine 1 status: State Online Standby CPU Temperature 40 degrees C / 104 degrees F
显示机箱环境路由引擎(EX9251 交换机)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master
show chassis environment 路由引擎(EX9253 交换机)
user@switch> show chassis environment routing-engine Routing Engine 0 status: State Online Master Routing Engine 1 status: State Present
发布信息
在 Junos OS 7.4 版之前引入的命令。
在 Junos OS 9.6 版中为 TX Matrix Plus 路由器引入的 sfc 选项。