request system software nonstop-upgrade
Sintaxe
request system software nonstop-upgrade (package-name | set [package-name package-name]) <force-host> <no-copy> <no-old-master-upgrade> <reboot > <unlink>
Descrição
Realize uma atualização ininterrupta de software (NSSU) em um switch com mecanismos de roteamento redundantes ou em um Virtual Chassis ou Virtual Chassis Fabric (VCF). O comportamento deste comando depende do tipo de switch, Virtual Chassis ou VCF onde você o executa, da seguinte forma:
-
Quando você executa este comando em qualquer uma das seguintes configurações de Virtual Chassis ou VCF, o NSSU atualiza todos os membros do Virtual Chassis:
-
EX3300, EX3400, EX4200, EX4300,EX4400, EX4500, EX4550, EX4600 ou EX4650-48Y Virtual Chassis
-
Virtual Chassi misto composto por qualquer combinação de switches EX4200, EX4500 e EX4550, ou switches EX4300 e EX4600
-
Chassi virtual QFX3500 e QFX3600
-
QFX5100 Virtual Chassis
-
chassi virtual QFX5120-48Y, QFX5120-48T ou QFX5120-32C
-
Configuração fixa de switches em um VCF (switches de QFX3500/QFX3600 e QFX5100)
-
VCF misto composto por qualquer combinação de switches QFX3500/QFX3600, QFX5100 e EX4300
O Virtual Chassis original ou o backup VCF tornam-se o principal. A nova primária atualiza e reinicia automaticamente as primárias originais, que então retomam o Virtual Chassis ou o VCF como backup.
-
Quando você executa este comando em um switch EX6200 ou EX8200, o NSSU atualiza os mecanismos de roteamento primário e de backup. O mecanismo de roteamento de backup original torna-se o novo principal ao final da atualização.
Em um switch EX6200, o NSSU reinicia automaticamente o mecanismo de roteamento primário original.
Em um switch EX8200, o NSSU não reinicia automaticamente o mecanismo de roteamento primário original a menos que você especifique a opção
reboot
.
Quando você executa este comando em um Virtual Chassis EX8200, o NSSU atualiza todos os mecanismos de roteamento primários e de backup no Virtual Chassis, incluindo os mecanismos externos de roteamento. Os mecanismos de roteamento de backup originais tornam-se os novos mecanismos de roteamento primários. O NSSU não reinicia automaticamente os mecanismos de roteamento primários originais a menos que você especifique a opção
reboot
.
Este comando tem os seguintes requisitos:
Todos os membros do Virtual Chassis, membros do VCF e todos os Mecanismos de roteamento devem estar executando a mesma versão do Junos OS.
Você deve habilitar o switchover gracioso do mecanismo de roteamento (GRES)..
Você deve habilitar o roteamento ativo sem parar (NSR).
Nota:Embora não seja necessário, recomendamos que você também habilite a ponte sem interrupções (NSB). O NSB garante que todos os protocolos de Camada 2 suportados por NSB operem perfeitamente durante a transição do mecanismo de roteamento durante o NSSU. Veja configuração de pontes sem interrupções em switches da Série EX (procedimento CLI).
Você deve executar o comando do mecanismo de roteamento primário em um switch autônomo ou das primárias em um Virtual Chassis.
Para uma interrupção mínima no tráfego, você deve definir grupos de agregação de enlaces (LAGs) de modo que os links de membro residam em diferentes switches virtuais de chassi ou membro VCF (ou em diferentes placas de linha para switches EX6200 e EX8200 e Virtual Chassis EX8200).
Para todos os Virtual Chassis (exceto chassi virtual EX8200):
Os membros do Virtual Chassis devem estar conectados em uma topologia em anel. Uma topologia em anel impede que o Virtual Chassis se separe durante um NSSU.
O virtual Chassis principal e o backup devem estar adjacentes entre si na topologia do anel. Com a colocação adjacente, o principal e o backup estão sempre em sincronia, enquanto os switches em funções de placa de linha estão sendo reiniciados.
O Virtual Chassis deve ser pré-provisionado para que a função de placa de linha seja explicitamente atribuída aos switches de membros que atuam em uma função de placa de linha. Durante um NSSU, os switches de membro principal e de backup devem manter suas funções de Mecanismo de Roteamento (embora a função principal switches para o backup), e os switches restantes devem manter suas funções de placa de linha.
Em um Virtual Chassis de dois membros, você deve configurar
no-split-detection
para que o Virtual Chassis não se divida durante o NSSU.
Para a malha virtual do chassi:
Você só pode ter dois membros pré-provisionados na função mecanismo de roteamento. Se mais de dois mecanismos de roteamento estiverem configurados, o NSSU emite uma mensagem de aviso e o processo NSSU para.
Os membros do VCF devem estar conectados em uma topologia spine e leaf. Uma topologia spine e leaf impede que o VCF se separe durante o NSSU. Cada dispositivo leaf deve ser conectado a ambos os dispositivos spine.
O VCF deve ser pré-provisionado para que a função de placa de linha tenha sido explicitamente atribuída aos switches de membros que atuam em uma função de placa de linha, e da mesma forma a função mecanismo de roteamento foi explicitamente atribuída aos switches membros que atuam em uma função de mecanismo de roteamento. Durante um NSSU, os switches de membro principal e de backup devem manter suas funções de Mecanismo de Roteamento (embora a função principal switches para o backup), e os switches restantes devem manter suas funções de placa de linha.
Você deve configurar
no-split-detection
em um VCF de dois membros para que o VCF não se divida durante o NSSU.
Opções
package-name | Localização do pacote ou pacote de software a ser instalado. Por exemplo:
Nota:
O |
set [package-name package-name] | (Apenas virtual chassi misto) Locais dos diferentes pacotes de instalação exigidos pelos diferentes tipos de switches de membros. Esses pacotes devem ser para a mesma versão do Junos OS. Veja a opção deste comando |
force-host | (Opcional) Force a inclusão do pacote ou pacote de software do host (e ignore os avisos) em dispositivos EX4650, QFX5100 ou QFX5120. |
no-copy | (Opcional) Instale um pacote ou pacote de software, mas não economize cópias do pacote ou arquivos de pacotes. |
no-old-master-upgrade | (Opcional) (somente switches EX8200) Atualize apenas o mecanismo de roteamento de backup. Após a conclusão da atualização, o mecanismo de roteamento primário original torna-se o mecanismo de roteamento de backup e continua executando a versão de software anterior. |
reboot | (Opcional) (apenas switches EX8200 e Virtual Chassis EX8200) Quando você inclui a opção, o
Nota:
Se você não usar a opção |
unlink | (Opcional) Remova o pacote de software após uma atualização bem-sucedida. |
Nível de privilégio exigido
Manutenção
Campos de saída
Este comando relata feedback sobre o status da solicitação. Algumas funções são compartilhadas entre o NSSU e o recurso de atualização de software em serviço (ISSU), para que você possa ver o que parecem ser mensagens ISSU, bem como mensagens NSSU na saída deste comando.
Saída de amostra
- solicitar atualização ininterrupta do software do sistema (Virtual Chassis EX4200)
- solicitar atualização ininterrupta do software do sistema (switch EX6200)
- solicitar reinicialização sem parar do software do sistema (switch EX8200)
- solicitar atualização ininterrupta do software de sistema sem upgrade antigo (switch EX8200)
- reinicialização ininterrupta do software do sistema de solicitação (Virtual Chassis EX8200)
solicitar atualização ininterrupta do software do sistema (Virtual Chassis EX4200)
user@switch> request system software nonstop-upgrade /var/tmp/jinstall-ex-4200–12.1R5.5–domestic-signed.tgz Chassis ISSU Check Done ISSU: Validating Image ISSU: Preparing Backup RE Installing image on other FPC's along with the backup Checking pending install on fpc1 Pushing bundle to fpc1 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc1 Checking pending install on fpc2 Pushing bundle to fpc2 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc2 Checking pending install on fpc3 Pushing bundle to fpc3 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc3 Checking pending install on fpc4 Pushing bundle to fpc4 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc4 Checking pending install on fpc5 Pushing bundle to fpc5 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc5 Checking pending install on fpc6 Pushing bundle to fpc6 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc6 Checking pending install on fpc7 Pushing bundle to fpc7 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Completed install on fpc7 Backup upgrade done Rebooting Backup RE Rebooting fpc1 ISSU: Backup RE Prepare Done Waiting for Backup RE reboot GRES operational Initiating Chassis In-Service-Upgrade Chassis ISSU Started ISSU: Preparing Daemons ISSU: Daemons Ready for ISSU ISSU: Starting Upgrade for FRUs ISSU: Preparing for Switchover ISSU: Ready for Switchover Checking In-Service-Upgrade status Item Status Reason FPC 0 Online FPC 1 Online FPC 2 Online (ISSU) FPC 3 Online (ISSU) FPC 4 Online (ISSU) FPC 5 Online (ISSU) FPC 6 Online (ISSU) FPC 7 Online (ISSU) Going to install image on master WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately relinquish mastership ISSU: IDLE *** FINAL System shutdown message from root@switch *** System going down IMMEDIATELY Shutdown NOW! [pid 9336]
solicitar atualização ininterrupta do software do sistema (switch EX6200)
{master} user@switch> request system software nonstop-upgrade /var/tmp/jinstall-ex-6200–12.2R5.5–domestic-signed.tgz Chassis ISSU Check Done ISSU: Validating Image ISSU: Preparing Backup RE Pushing bundle to re0 NOTICE: Validating configuration against jinstall-ex-6200–12.2R5.5–domestic-signed.tgz. NOTICE: Use the 'no-validate' option to skip this if desired. WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Backup upgrade done Rebooting Backup RE Rebooting re0 ISSU: Backup RE Prepare Done Waiting for Backup RE reboot GRES operational Initiating Chassis In-Service-Upgrade Chassis ISSU Started ISSU: Preparing Daemons ISSU: Daemons Ready for ISSU ISSU: Starting Upgrade for FRUs ISSU: Preparing for Switchover ISSU: Ready for Switchover Checking In-Service-Upgrade status Item Status Reason FPC 0 Online (ISSU) FPC 1 Online (ISSU) FPC 2 Online (ISSU) FPC 3 Online (ISSU) FPC 4 Online FPC 5 Online FPC 6 Online (ISSU) FPC 7 Online (ISSU) FPC 8 Online (ISSU) FPC 9 Online (ISSU) Going to install image on master NOTICE: Validating configuration against jinstall-ex-6200–12.2R5.5–domestic-signed.tgz. NOTICE: Use the 'no-validate' option to skip this if desired. WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately relinquish mastership ISSU: IDLE Trying to relinquish mastership before rebooting... Resolving mastership... Complete. The other routing engine becomes the master. *** FINAL System shutdown message from user@switch *** System going down IMMEDIATELY
solicitar reinicialização sem parar do software do sistema (switch EX8200)
{master} user@switch> request system software nonstop-upgrade reboot /var/tmp/jinstall-ex-8200–10.4R1.5–domestic-signed.tgz Chassis ISSU Check Done ISSU: Validating Image ISSU: Preparing Backup RE Pushing bundle to re1 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Backup upgrade done Rebooting Backup RE Rebooting re1 ISSU: Backup RE Prepare Done Waiting for Backup RE reboot GRES operational Initiating Chassis In-Service-Upgrade Chassis ISSU Started ISSU: Preparing Daemons ISSU: Daemons Ready for ISSU ISSU: Starting Upgrade for FRUs ISSU: Preparing for Switchover ISSU: Ready for Switchover Checking In-Service-Upgrade status Item Status Reason FPC 0 Online (ISSU) FPC 2 Offline Offlined by CLI command FPC 3 Online (ISSU) Resolving mastership... Complete. The other routing engine becomes the master. ISSU: RE switchover Done ISSU: Upgrading Old Master RE WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately ISSU: Old Master Upgrade Done ISSU: IDLE Shutdown NOW! [pid 2635] *** FINAL System shutdown message from user@switch *** System going down IMMEDIATELY
solicitar atualização ininterrupta do software de sistema sem upgrade antigo (switch EX8200)
{master} user@switch> request system software nonstop-upgrade no-old-master-upgrade /var/tmp/jinstall-ex-8200–10.4R1.5–domestic-signed.tgz Chassis ISSU Check Done ISSU: Validating Image ISSU: Preparing Backup RE Pushing bundle to re1 WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Backup upgrade done Rebooting Backup RE Rebooting re1 ISSU: Backup RE Prepare Done Waiting for Backup RE reboot GRES operational Initiating Chassis In-Service-Upgrade Chassis ISSU Started ISSU: Preparing Daemons ISSU: Daemons Ready for ISSU ISSU: Starting Upgrade for FRUs ISSU: Preparing for Switchover ISSU: Ready for Switchover Checking In-Service-Upgrade status Item Status Reason FPC 0 Online (ISSU) FPC 1 Online (ISSU) FPC 2 Online (ISSU) FPC 3 Offline Offlined by CLI command FPC 4 Online (ISSU) FPC 5 Online (ISSU) FPC 6 Online (ISSU) FPC 7 Online (ISSU) Resolving mastership... Complete. The other routing engine becomes the master. ISSU: RE switchover Done Skipping Old Master Upgrade ISSU: IDLE
reinicialização ininterrupta do software do sistema de solicitação (Virtual Chassis EX8200)
{master:9} user@external-routing-engine> request system software nonstop-upgrade reboot /var/tmp/jinstall-ex-xre200-11.1-20101130.0-domestic-signed.tgz Chassis ISSU Check Done ISSU: Validating Image ISSU: Preparing LCC Backup REs ISSU: Preparing Backup RE Pushing bundle /var/tmp/jinstall-ex-xre200-11.1-20101130.0-domestic-signed.tgz to member8 -------------------------------------------------------------------------- WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately VC Backup upgrade done Rebooting VC Backup RE Rebooting member8 ISSU: Backup RE Prepare Done Waiting for VC Backup RE reboot Pushing bundle to member0-backup Pushing bundle to member1-backup WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Rebooting member0-backup Rebooting LCC [member0-backup] Rebooting member1-backup Rebooting LCC [member1-backup] ISSU: LCC Backup REs Prepare Done GRES operational Initiating Chassis Nonstop-Software-Upgrade Chassis ISSU Started ISSU: Preparing Daemons ISSU: Daemons Ready for ISSU ISSU: Starting Upgrade for FRUs ISSU: Preparing for Switchover ISSU: Ready for Switchover Checking Nonstop-Upgrade status member0: -------------------------------------------------------------------------- Item Status Reason FPC 0 Online (ISSU) FPC 1 Online (ISSU) FPC 2 Online (ISSU) FPC 5 Online (ISSU) member1: -------------------------------------------------------------------------- Item Status Reason FPC 0 Online (ISSU) FPC 1 Offline Offlined due to config FPC 2 Online (ISSU) FPC 3 Online (ISSU) FPC 4 Online (ISSU) FPC 5 Online (ISSU) FPC 7 Online (ISSU) member0: -------------------------------------------------------------------------- Item Status Reason FPC 0 Online (ISSU) FPC 1 Online (ISSU) FPC 2 Online (ISSU) FPC 5 Online (ISSU) member1: -------------------------------------------------------------------------- Item Status Reason FPC 0 Online (ISSU) FPC 1 Offline Offlined due to config FPC 2 Online (ISSU) FPC 3 Online (ISSU) FPC 4 Online (ISSU) FPC 5 Online (ISSU) FPC 7 Online (ISSU) ISSU: Upgrading Old Master RE Pushing bundle /var/tmp/incoming-package-8200.tgz to member0-master Pushing bundle /var/tmp/incoming-package-8200.tgz to member1-master ISSU: RE switchover Done WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Rebooting ... shutdown: [pid 2188] Shutdown NOW! ISSU: Old Master Upgrade Done ISSU: IDLE Shutdown NOW! *** FINAL System shutdown message from root@ *** System going down IMMEDIATELY
Informações de versão
Comando introduzido no Junos OS Release 10.4.
Opção set [package-name package-name]
adicionada no Junos OS Release 12.1 para switches da Série EX.