Performance
- Total reduction throughput speed: 2 Mbps to 10 Mbps
- IPsec throughput: 15 Mbps
- Tunnels supported: Up to 50 with all features enabled*
* Requires software upgrade to WXOS 5.7 - Disk capacity: 250 GB
Connections
Network interfaces: Two copper 10/100/1000 Ethernet ports
Power requirement
Dual 100-240 VAC, 50-60 Hz, 75 Watts avg or 256 BTU/hr
Dimensions and Weight
- (W x H x D): 17.5 x 1.8 x 14.5 in (44.5 x 4.6 x 36.8 cm) 1 rack units
- Weight: 17 lb (7.7 kg)
Operating Environment
- Temperature: 41° to 104° F (5° to 40° C)
- Humidity: 10% to 85%, noncondensing at 95° F (35° C)
- Maximum altitude: 10,000 ft (3,048 m)
Nonoperating Environment
- Temperature: -40° to 158° F (-40° to 70° C)
- Humidity: 5% to 95%, noncondensing at 95° F (35° C)
- Maximum altitude: 40,000 ft (12,192 m)
Regulations
- Emissions: FCC Class A, EN 55022 Class A, EN 55024 Immunity, EN 61000-3-2, VCCI Class A
- Safety: CAN/CSA-C22.2 No. 60950-1-03 - UL 60950-1 and EN 60950-1
- Acoustic noise: Maximum noise level is less than 55 dB
WXC Series Application Acceleration Platforms
Junos Pulse Application Acceleration Service
Enterprise Product Portfolio
WXC Central Management System for WXC Series Application Acceleration Platforms
The table below reflects base models only. Bandwidth upgrades and options such as redundant hard drives, power supplies, and fans (WXC3400 and WXC590 only) are also available. Please contact your Juniper Networks representative or reseller for details.
| Model Number | Description |
| WXC2600-A | WXC2600, incl. RTU SW License to 2 Mbps |
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.