[Contents] [Prev] [Next] [Report an Error] [No Frames]


Provisioning Server Enhancements

The following changes have been made for the Provisioning Service.

ATM Subinterface Provisioning Object

The ATMSUBINTF_DISTINGUISHER attribute has been added to the ATMSubInterface object type in the unspRXDeviceMgr.idl file. It was also added to the NMC-RX application.
Attribute
Characteristic
Description
MIB Entry

ATMSUBINTF_DISTINGUISHER

Create

ATM identifier used to uniquely characterize the subinterface on this ATM interface.

juniAtmSubIfDistinguisher


ATM PVC Provisioning Object

The characteristic in the ATM PVC object type in the unspRXDeviceMgr.idl file has been changed from View to Create.
Attribute
Characteristic
Description
MIB Entry

VCD

Create

Virtual circuit descriptor

juniAtmSubIfVccVcd


PVS Test Utility Dialog Box

Two new fields, EMS Name and Port, have been added to the PVS Test Utility dialog box. You can now name and run multiple uniquely named PVS Services to one NMC-RX database.

Running Multiple PVS Services to One NMC-RX Database

To run multiple uniquely named PVS Services to one NMC-RX database, follow these steps. Note that there must be one dedicated Provisioning Service for each CORBA client:

  1. Start the Naming Service.
  2. Modify the PVS.rc file by assigning a unique emsName and server port for the Provisioning Service.
  3. Start the NMC RMI Service.
  4. Start the NMC CORBA Service.
  5. Start the PVS Test Utility, and confirm that the emsName (Provisioning Service) is up and functioning as expected.
  6. Modify the PVS.rc file again by assigning a different emsName and server port for the Provisioning Service.
  7. Repeat step 3-5.

[Contents] [Prev] [Next] [Report an Error] [No Frames]