Events Detected By AI-Scripts
Table 1 lists the events detected by Release 2.1 of the AI-Scripts.
Table 1: Events Detected by AI-Scripts
| Event ID | Description |
ACCT_MALLOC_FAILURE | The accounting statistics process could not allocate memory from the heap. |
ACCT_XFER_POPEN_FAIL | A failed call to the popen() function when the accounting statistics process invokes the indicated command to transfer the indicated file. |
ASP_IDS_INV_CLEAR_QUERY | The intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request includes the indicated type of query, which IDS cannot interpret. |
ASP_IDS_INV_CLEAR_QUERY_VER | The Intrusion detection services (IDS) receives a request to clear information from the IDS tables. The request version number did not match the version number of requests that IDS can service. |
ASP_L2TP_OBJ_CAC_FAIL | The Layer 2 Tunneling Protocol (L2TP) could not allocate memory from an object cache for the flow defined by the indicated unit, tunnel, and session. |
ASP_L2TP_NO_MEM | The Layer 2 Tunneling Protocol (L2TP) could not allocate the memory it needed to create a flow for the indicated tunnel and session. |
ASP_PGCP_IPC_PIPE_WRITE_FAILED | The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write an interprocess communication (IPC) message to the end of its pipe. |
ASP_PGCP_IPC_PIPE_WRITE_FAILED | The Packet Gateway Control Protocol (PGCP) client on the Services Port Interface Card failed to write the contents of its interprocess communication (IPC) pipe to the socket layer. |
AUDITD_RADIUS_OPEN_FAILED | The audit process (auditd) could not create a RADIUS object handle used for various RADIUS operations. |
AUDITD_RADIUS_REQ_CREATE_FAILED | The audit process (auditd) could not create a RADIUS accounting request for the indicated reason. |
AUDITD_SOCKET_FAILURE | The audit process (auditd) listens on a Transmission Control Protocol (TCP) socket for system accounting events reported by other processes on the routing platform. The indicated socket operation failed with the indicated error. |
AUTHD_AUTH_CREATE_FAILED | The generic authentication service process (authd) could not allocate an authentication object for the indicated reason. |
AUTHD_SERVER_INIT_BIND_FAIL | The generic authentication service process (authd) could not bind the server to the address specified. |
AUTHD_SERVER_INIT_LISTEN_FAIL | The generic authentication service process (authd) could not initialize listening on the server for the indicated socket. |
AUTHD_SETSOCKOPT_FAILED | The generic authentication service process (authd) could not set socket options during the indicated operation. |
AUTHD_SOCKET_FAILED | The generic authentication service process (authd) could not open a socket during the indicated operation. |
AUTOD_RECV_FAILURE | The autoinstallation process (autod) received the indicated error when it tried to receive data on a socket. |
AUTOD_SEND_FAILURE | The autoinstallation process (autod) receives the indicated error when it sends data on a socket. |
AUTOD_SOCKET_CREATE_FAILURE | The autoinstallation process (autod) receives the indicated error when it creates a socket. |
AV_PATTERN_KL_CHECK_FAILED | The device is unable to use the Kaspersky pattern file. The error message provides information to give Juniper Networks technical support. |
AV_PATTERN_TOO_BIG | The pattern file size specified in the server initialization file (server.ini) exceeds the maximum prescribed limit. |
AV_PATTERN_WRITE_FS_FAILED | The device is unable to save the contents of an antivirus pattern file to the file system. |
BFDD_READ_ERROR | The Bidirectional Forwarding Detection process (bfdd) could not read a message available on the indicated type of pipe. |
BFDD_WRITE_ERROR | The Bidirectional Forwarding Detection process (bfdd) could not write a message to the indicated type of pipe. |
BOOTPD_HWDB_ERROR | The boot parameter process (tnp.bootpd) could not complete an operation in the hardware database maintained by the chassis process (chassisd), for the indicated reason. |
CFMD_RTSOCK_OPEN_FAILURE | The connectivity fault management process (cfmd) could not successfully open a routing socket to the kernel, for the indicated reason. |
CHASSISD_BUS_DEVICE_OPEN_FAILURE | The chassis process (chassisd) could not open the indicated bus device for the indicated reason. |
CHASSISD_CLOCK_FAILURE | The chassis process (chassisd) determined that the indicated clock source failed in the indicated way. |
CHASSISD_COMMAND_ACK_ERROR | The chassis process requested that the indicated component (field-replaceable unit, or FRU) confirm that it was online. The indicated error occurred when the FRU sent its response. In the normal case, the chassis process performed any additional action necessary to guarantee that the FRU came online. |
CHASSISD_COMMAND_ACK_SFM_ERROR | The chassis process (chassisd) requires an acknowledgment from each Switching and Forwarding Module (SFM) before it registers a Flexible PIC Controller (FPC) as online. The acknowledgment message from the indicated SFM failed for the indicated FPC. |
CHASSISD_CMB_READBACK_ERROR | The chassis process (chassisd) could not read back information from the Chassis Management Bus (CMB) about the indicated component (field-replaceable unit, or FRU). |
CHASSISD_FAN_FAILURE | The indicated fan or impeller failed. The chassis process (chassisd) raised an alarm and increased the speed of the remaining fans (and impellers, if applicable) to full speed. |
CHASSISD_FASIC_FTOKEN_ERROR | The chassis process (chassisd) detected an underflow or overflow error on the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_PLL_ERROR | The chassis process (chassisd) could not lock a phased-lock loop (PLL) for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_FTOKEN_INIT_ERROR | The chassis process (chassisd) encountered an error while initializing memory at the indicated address for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_HSL_CONFIG_ERROR | The chassis process (chassisd) could not configure high speed links (HSL) for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_HSL_LINK_ERROR | The chassis process (chassisd) detected an error for the indicated high-speed link (HSL) for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_INIT_ERROR | The chassis process (chassisd) detected that F chips were not yet initialized on the Control Board (CB). |
CHASSISD_FASIC_INPUT_DROP | The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data that was received from the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per second. |
CHASSISD_FASIC_OUTPUT_DROP | The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data before sending it to the indicated Packet Forwarding Engine on the indicated Flexible Port Concentrator (FPC) for outgoing transmission, it dropped the indicated number of cells per second. |
CHASSISD_FASIC_PIO_READ_ERROR | The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB). |
CHASSISD_FASIC_PIO_WRITE_ERROR | The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB). |
CHASSISD_FASIC_PLL_ERROR | The chassis process (chassisd) could not lock a phased-lock loop (PLL) for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_RESET_ERROR | The chassis process (chassisd) could not reset the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FASIC_SRAM_ERROR | The chassis process (chassisd) detected that SRAM failed to initialize for the indicated F chip on the indicated Control Board (CB). |
CHASSISD_FCHIP_CONFIG_MD_ERROR | The chassis process (chassisd) detected an invalid number of Md chips for the indicated F chip, Packet Forwarding Engine and Flexible PIC Concentrator (FPC). |
CHASSISD_FCHIP_HSR_ERROR | The chassis process (chassisd) detected an error in the high-speed receiver (HSR) subsystem for the F chip with the indicated characteristics. |
CHASSISD_FCHIP_HST_ERROR | The chassis process (chassisd) detected an error in the high-speed transmitter (HST) subsystem for the F chip with the indicated characteristics. |
CHASSISD_FCHIP_LINK_ERROR | The chassis process (chassisd) detected an error for the indicated high-speed receiver (HSR) or high-speed transmitter (HST) link for an F chip on the indicated Switch Interface Board (SIB). |
CHASSISD_FCHIP_MONITOR_ERROR | The chassis process (chassisd) detected an invalid F-chip module while enabling or disabling the monitoring of F-chip functional blocks. |
CHASSISD_FCHIP_PIO_READ_ERROR | The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link. |
CHASSISD_FCHIP_PIO_WRITE_ERROR | The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link. |
CHASSISD_FHSR_READ_REG_ERROR | The high-speed receiver (HSR) read routine failed at the indicated address on an F-chip register. |
CHASSISD_FHSR_WRITE_REG_ERROR | The high-speed receiver (HSR) write routine could not record the indicated value at the indicated address on an F-chip register. |
CHASSISD_FHST_READ_REG_ERROR | The high-speed transmitter (HST) read routine failed at the indicated address on an F-chip register. |
CHASSISD_FHST_WRITE_REG_ERROR | The high-speed transmitter (HST) write routine could not record the indicated value at the indicated address on an F-chip register. |
CHASSISD_FILE_OPEN | The chassis process (chassisd) could not open the indicated file for the indicated reason. |
CHASSISD_FM_ERROR | During execution of the indicated fabric management routine, the indicated error occurred between the indicated Switch Interface Board (SIB) and the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC). |
CHASSISD_FM_ERROR_SIB_L_FB_HSR | In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T640 routing nodes (called SIB-Ls) and the SIBs in the TX Matrix platform (called SIB-Ss). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected an error in the electrical path between the indicated ports on the SIB-L and the corresponding SIB-S. |
CHASSISD_FM_ERROR_SIB_L_FB_SMF | In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (the switch-card chassis, or SCC) and the SIBs in the T640 routing nodes (called SIB-Ls). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media. |
CHASSISD_FM_ERROR_SIB_S_FB_HSR | In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routing nodes (called SIB-Ls). The chassis process (chassisd) on the TX Matrix platform detected an error in the electrical path between the indicated port on the indicated SIB-S and the indicated port on a SIB-L installed in the indicated routing node (line-card chassis, or LCC). |
CHASSISD_FM_ERROR_SIB_S_FB_SMF | In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routing nodes (line-card chassis, or LCCs). The chassis process (chassisd) on the TX Matrix platform detected the indicated error as packets that were traveling to or from the indicated LCC were translated between electrical and optical media. |
CHASSISD_FM_SIB_ERROR | The chassis process (chassisd) detected the indicated type of error on the indicated Switch Interface Board (SIB) and performed the indicated action. |
CHASSISD_FPC_PIC_DETECT_TIMEOUT | The chassis process (chassisd) expects to receive notification within a timeout period that each Flexible PIC Concentrator (FPC) has attached the Physical Interface Cards (PICs) that it houses. It did not receive notification from the indicated FPC. |
CHASSISD_FRU_INVALID_SLOT | The chassis process (chassisd) detected that the indicated hardware component (field-replaceable unit, or FRU) was inserted in a slot that is not valid for that component type. |
CHASSISD_GBUS_NOT_READY | The GBUS was not ready when the chassis process (chassisd) first tried to power it on, and the power-up operation timed out. |
CHASSISD_GBUS_READBACK_ERROR | There was an error when the chassis process (chassisd) tried to read back information from the GBUS on the indicated component (field-replaceable unit, or FRU). |
CHASSISD_HSR_FIFO_ERROR | A first-in, first-out (FIFO) read error occurred during execution of the indicated routine on the indicated high-speed receiver (HSR). |
CHASSISD_I2C_BAD_IDEEPROM_FORMAT | The chassis process (chassisd) determined that the ID EEPROM format specified for the indicated type of hardware component (field-replaceable unit, or FRU) is not valid for it. |
CHASSISD_I2C_READ_ERROR | The chassis process (chassisd) cannot read I2C data from the indicated device. |
CHASSISD_I2CS_READBACK_ERROR | The chassis process (chassisd) cannot read back information from the I2C slave (I2CS) about the indicated component (field-replaceable unit, or FRU). |
CHASSISD_IFDEV_DETACH_FPC | The chassis process (chassisd) detached the interface devices for all Physical Interface Cards (PICs) on the indicated flexible PIC concentrator (FPC). |
CHASSISD_IFDEV_DETACH_PIC | The chassis process (chassisd) detached the interface devices for the indicated Physical Interface Card (PIC). |
CHASSISD_IPC_CONNECTION_DROPPED | The chassis process (chassisd) dropped the interprocess communication (IPC) connection to the indicated component (field-replaceable unit, or FRU). |
CHASSISD_IPC_DAEMON_WRITE_ERROR | The chassis process (chassisd) could not write to a socket, because of the indicated error. The socket is for a connection to another process that runs on the Routing Engine and helps manage the chassis. |
CHASSISD_IPC_MSG_DROPPED | The chassis process (chassisd) dropped an interprocess communication (IPC) message because the message queue had already reached maximum capacity. |
CHASSISD_IPC_MSG_UNHANDLED | The chassis process (chassisd) received an interprocess communication (IPC) message about the indicated FRU. The message had the indicated characteristics. The chassisd process could not handle the message. |
CHASSISD_IPC_WRITE_ERR_NULL_ARGS | The chassis process (chassisd) could not send a message to the indicated component (field-replaceable unit, or FRU) because one or more required parameters had a null value. |
CHASSISD_MAC_ADDRESS_ERR | The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated interface because of an internal error. |
CHASSISD_MAC_ADDRESS_FABRIC_ERR | The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated fabric interface because of an internal error. |
CHASSISD_MALLOC_FAILURE | The chassis process (chassisd) could not allocate memory. The chassisd process tried to continue functioning, but the lack of memory usually causes the process to fail. An administrator needs to restart it. |
CHASSISD_MBE_DETECTED | A multi-bit ECC parity error was detected in Routing Engine DRAM. |
CHASSISD_OVER_TEMP_CONDITION | The temperature of one or more components (field-replaceable units, or FRUs) exceeded the indicated temperature, which is the upper of two thresholds. The fans (and impellers, if applicable) were in the indicated state. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, the chassisd process shuts down the routing platform. When this message was logged, the indicated number of seconds remained before shutdown. |
CHASSISD_OVER_TEMP_SHUTDOWN_TIME | The chassis process (chassisd) shut down the routing platform because the temperature of one or more components exceeded the indicated threshold temperature for the indicated amount of time. Continued operation at the excessive temperature could damage the routing platform. |
CHASSISD_PEM_OVERLOAD | The indicated power entry module (PEM) reported an output voltage overload condition. |
CHASSISD_PEM_VOLTAGE | The indicated power entry module (PEM) reported a problem with its output voltage. |
CHASSISD_POWER_CONDITION | The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. |
CHASSISD_RE_OVER_TEMP_CONDITION | The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. |
CHASSISD_PSU_ERROR | The chassis process (chassisd) detected the indicated error condition for the indicated power supply unit (PSU). |
CHASSISD_PSU_FAN_FAIL | The PSU fan-fail bit is set in the status for the indicated power supply unit (PSU). |
CHASSISD_PSU_INPUT_BAD | The chassis process (chassisd) detected the input voltage/warning fault condition for the indicated power supply unit (PSU). |
CHASSISD_PSU_OVERLOAD | The indicated power supply unit (PSU) reported an output voltage overload condition. |
CHASSISD_PSU_TEMPERATURE | The chassis process (chassisd) detected that the temperature check bit was set in the status bit mask for the indicated power supply unit (PSU). |
CHASSISD_PSU_VOLTAGE | The indicated power supply unit (PSU) reported a problem with its output voltage. |
CHASSISD_RE_OVER_TEMP_SHUTDOWN | The chassis process (chassisd) performed the indicated action because the temperature of the indicated Routing Engine exceeded the maximum threshold for more than four minutes. Continued operation at the excessive temperature could damage routing platform components. |
CHASSISD_RE_OVER_TEMP_WARNING | The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, the chassisd process shuts down the indicated component. When this message was logged, the indicated number of seconds remained before shutdown. |
CHASSISD_SBE_DETECTED | Too many single-bit correctable ECC parity errors were detected in Routing Engine DRAM. |
CHASSISD_SMB_INVALID_PS | The chassis process (chassisd) could not set the status (enabled or disabled) for a power supply, because it received the indicated power supply status code, which is invalid. |
CHASSISD_SMB_IOCTL_FAILURE | The indicated ioctl() operation failed at the indicated address on the system management bus (SMB). |
CHASSISD_SMB_READ_FAILURE | A read() operation failed at the indicated address on the system management bus (SMB). |
CHASSISD_TEMP_SENSOR_FAILURE | The temperature sensor for the indicated component (field-replaceable unit, or FRU) either did not respond to a request from the chassis process (chassisd) for a temperature reading or sent a value that is outside the normal operating range. |
CHASSISD_TIMER_VAL_ERR | The chassis process (chassisd) started a timer to track the timeout period for an event. The timer returned a null identifier, so the chassisd process could not clear the timer.. |
CHASSISD_VOLTAGE_READ_FAILED | The chassis process (chassisd) could not read the voltage data from the indicated component (field-replaceable unit, or FRU). |
CHASSISD_VOLTAGE_SENSOR_INIT | The chassis process (chassisd) could not initialize the voltage sensor for the indicated component (field-replaceable unit, for FRU). |
CHASSISD_UNEXPECTED_EXIT | The chassis process (chassisd) exited unexpectedly and reported the indicated error. |
COSD_MALLOC_FAILED | The class-of-service (CoS) process (cosd) could not dynamically allocate memory, for the indicated reason. |
COSD_RTSOCK_LIB_ERR | COSD uses rtsock library for reading and writing data from and to kernel. The specified error occurred while using rtsock library to read/write data. |
COSD_RTSOCK_WRITE_FAILED | COSD uses rtsock to read/write data from kernel. If the write fails kernel returns an error. |
COSD_UNEXPECTED_EXIT | COSD waits for the event notifications and processes the events that it is registered for. There was an error during event-handling initialization. |
COSD_UNKNOWN_TRANSLATION_TABLE | The class-of-service (CoS) process (cosd) did not recognize the indicated translation table type from the rtsock library. |
Daemon Crash | A JUNOS daemon crash occurred with a core dump. |
DCD_CONFIG_WRITE_FAILED | The DCD encountered an error while trying to send an interface configuration to the kernel over the routing socket. |
DCD_PARSE_STATE_EMERGENCY | The interface process (dcd) encountered an unhandled internal state during interface parsing. |
DCD_RTSOCK_READ_SYNC_NOBUF | The DCD communicates with the kernel by writing messages to and reading messages from routing sockets. The DCD could not allocate memory to use to read messages from the kernel. |
DCD_RTSOCK_SEND_NOBUF | If the Routing Engine is busy or operating under a heavy load, messages between the DCD and the kernel may be dropped. To detect whether messages have been dropped, the DCD and the kernel place sequence numbers in messages. The DCD detected that a message was dropped. In an attempt to recover the message, the DCD retries the operation. |
DFCD_GENCFG_MALLOC_FAILED | The dynamic flow capture process (dfcd) could not allocate memory for the gencfg message. |
DFCD_GENCFG_WRITE_FAILED | The dynamic flow capture process (dfcd) could not send the gencfg message for the indicated reason. |
DFCD_LINH_MALLOC_FAILED | The dynamic flow capture process (dfcd) could not allocate memory for the linh message. |
DCD_TRASHED_RED_ZONE | When DCD is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when de-allocating this memory, DCD checks for the pattern. If it does not find the previously written pattern, it means the memory was overwritten, which indicates an error in DCD. |
DFWD_CONFIG_WRITE_FAILED | The DFWD encountered an error while trying to send an interface configuration to the kernel over the routing socket. |
DFWD_MALLOC_FAILED | DFWD must dynamically malloc memory for its needs. This allocation request failed. The specific data structure that was being allocated is listed in the message. |
DFWD_PARSE_STATE_EMERGENCY | The firewall process (dfwd) encountered an unhandled internal state while parsing an interface. |
DFWD_TRASHED_RED_ZONE | When DFWD is allocating heap memory, it uses a private memory allocator that writes a special pattern at the end of each allocated segment of heap memory. Later, when de-allocating this memory, DFWD checks for the pattern. If it does not find the previously written pattern, it means the memory was overwritten, which indicates an error in DFWD. |
DH_SVC_RTSOCK_OPEN_FAILURE | The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error. |
DH_SVC_RTSOCK_REGISTER_FAILURE | The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not successfully register a callback function with a routing socket. The error string accompanying this log entry indicates the specific error. |
DH_SVC_SETSOCKOPT_FAILURE | The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not set the indicated socket option. |
DH_SVC_SOCKET_FAILURE | The Dynamic Host Configuration Protocol (DHCP) services process (dhcp-service) could not create a socket. |
EVENTD_EVENT_SEND_FAILED | JUNOS processes can request that the event processing process (eventd) notify them when a specific event occurs. The eventd process could not send an event notification for the indicated reason. |
EVENTD_FORK_ERR | The event processing process (eventd) could not create a child process for executing policies. |
EVENTD_PIPE_ERR | The event processing process (eventd) could not create a pipe for interprocess communication. |
EVENTD_VERSION_MISMATCH | The event processing process (eventd) received an event with the indicated version indicator, which does not match the indicated version expected by the eventd process. |
FPCLOGIN_IP_ADDRESS_GET_FAILURE | The fpclogin module attempted to get the IP address of the physical interface module. The attempt failed. |
FSAD_ERROR | The File System Access process (fsad) internal error message. |
FUD_MEMORY_ALLOCATION_FAILURE | The UDP forwarding process (fud) could not allocate the indicated amount of memory from the heap. |
FUD_RTSOCK_WRITE_FAILURE | The UDP Forwarding process (fud) could not write to its routing socket for the indicated reason. |
FUD_SENDMSG_FAILURE | The UDP Forwarding process (fud) could not send data to the indicated destination port and address using the indicated interface and routing instance, which it needs to do during normal operation. |
FUD_SENDMSG_NOINT_FAILURE | The UDP Forwarding process (fud) could not send data to the indicated destination port and address using the indicated routing instance, which it needs to do during normal operation. |
FUD_SETSOCKOPT_FAILURE | The UDP Forwarding process (fud) could not set the indicated socket option. |
FUD_SOCKET_FAILURE | The UDP Forwarding process (fud) could not create a socket. |
GGSN_ALARM_TRAP_SEND | An alarm trap to be relayed by the Services PICs process (serviced) failed to initialize. |
GGSN_TRAP_SEND | The system sent a GGSN trap of an unrecognized type. |
GRAPH_NO_MEMORY | The graphing process could not allocate memory while trying to create a graph. |
IDP_DAEMON_INIT_FAILED | An attempt to start the IDP policy daemon failed because an error was encountered during initialization. |
IDP_INTERNAL_ERROR | The IDP daemon encountered an internal error. |
IKED_CFG_PATRICIA_ERROR | A call to a Patricia tree library function returned an error. |
JCS_MM_COMMUNICATION_ERROR | The JCS process (jcsd) could not send an SNMP request to the Management Module because of the indicated error. |
JCS_BBD_LOAD_FAILURE | The JCS process (jcsd) could not load blade bay data for the specified blade. |
JCS_BBD_LOCAL_MISMATCH | The blade bay data retrieved for the specified blade does not match the data loaded during the reboot process. This error usually indicates that blade bay data in the JCS Management Module was changed since the last reboot. |
JCS_BBD_NOT_FOUND | The blade bay data was not found for the specified blade. |
JCS_BBD_NOT_VALID | The blade bay data for the specified blade is invalid. |
JCS_BBD_PARSE_ERROR | The blade bay data for the specified blade did not parse correctly. |
JCS_BBD_PEER_MISMATCH | The blade bay data retrieved for the specified peer blade does not match the data retrieved for the local blade. This error indicates that blade bay data in the JCS Management Module was not configured properly. |
JCS_KERNEL_RSD_LINK_DOWN | The JCS process (jcsd) has disabled kernel RSD communcation for the specified reason. |
JCS_READ_BANDWIDTH_ERROR | The indicated error occurred when attempting to read the current switch bandwidth. |
JCS_READ_BBD_ERROR | The indicated error occurred when attempting to read the current blade bay data via a sysctl call. |
JCS_SWITCH_COMMUNICATION_ERROR | The JCS process (jcsd) could not send an SNMP request to the indicated Switch Module because of the indicated error. |
JSRPD_DAEMONIZE_FAILED | The jsrpd process (jsrpd) could not create a version of itself to run in the background as a daemon. |
JSRPD_EVLIB_EXIT_FAILURE | The jsrpd process (jsrpd) returned from an event loop, which it should never do. |
JSRPD_SOCKET_CREATION_FAILURE | The jsrpd process (jsrpd) could not successfully create a socket. |
JSRPD_SOCKET_LISTEN_FAILURE | The jsrpd process (jsrpd) could not successfully listen on a socket. |
JSRPD_SOCKET_RECV_HB_FAILURE | The jsrpd process (jsrpd) was not successfully received on a socket. |
KERNEL: rdp retransmit error | The kernel is indicating that no system buffer space is available. |
KERNEL:RT_PFE: NH IPC failed, err 6 (No Memory) | The kernel is reporting that the packet forwarding engine cannot install or change routing table entries because the PFE is running out of memory. |
L2ALD_IPC_PIPE_WRITE_ERROR | The Layer 2 address learning process (l2ald) could not write to an interprocess communication (IPC) pipe for the indicated reason. |
L2CPD_ABORT | The Layer 2 Control Protocol process (l2cpd) terminated because of an internal error. |
L2CPD_ASSERT | The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. The l2cpd process with the indicated executable name and process ID (PID) terminated because the indicated test failed at the indicated line number in the indicated source file. The process created a diagnostic core file for analysis by technical support personnel. |
L2CPD_ASSERT_SOFT | The source code for the Layer 2 Control Protocol process (l2cpd) includes internal self-consistency tests. The l2cpd process with the indicated executable name and process ID (PID) terminated because the indicated type of check failed at the indicated line number in the indicated source file. The process continued to run, but created a diagnostic core file for analysis by technical support personnel. |
L2TPD_EVLIB_CREATE_FAILED | The Layer 2 Tunneling Protocol process (l2tpd) could not create a context for handling asynchronous events. |
L2CPD_PPM_WRITE_ERROR | The Layer 2 Control Protocol process (l2cpd) could not write a message on the pipe to the periodic packet management process (ppmd). |
L2CPD_SCHED_SLIP | L2CPD delayed an event, such as issuing an adjacency establishment message, that was supposed to occur at a particular time. The event did not occur at the right time. |
L2TPD_SERVER_START_FAILED | The Layer 2 Tunneling Protocol (L2TP) server did not start. |
L2CPD_SYSTEM_CALL_FAILED | A system call made by the Layer 2 control protocol process (L2CPD) failed. |
LACPD_DAEMONIZE_FAILED | The Link Aggregation Control Protocol process (lacpd) could not create a version of itself to run in the background as a daemon. |
LIBESPTASK_SNMP_CONN_PROG | The indicated error occurred while the process using libesptask was connecting to the SNMP master agent. |
LIBESPTASK_SNMP_SOCKOPT_RECVBUF | The process using libesptask could not set the size of the kernel receive buffer, which allows it to accept the largest possible packet from the Simple Network Management Protocol (SNMP) master agent. |
LIBESPTASK_SNMP_SOCKOPT_SENDBUF | The process using libesptask could not set the size of the kernel send buffer, which allows it to send the largest possible packet to the Simple Network Management Protocol (SNMP) master agent. |
LIBJNX_DEFAULT_IP_ADDR_NOT_SET | A JUNOS process could not retrieve the system default IP address from the kernel, because the address is not defined there. |
LIBJNX_REPLICATE_RCP_ERROR | The rcp command failed during replication. |
LIBJNX_EVLIB_FAILURE | A JUNOS process called the indicated function in the event library. The function failed for the indicated reason. |
LIBJNX_SNMP_ENGINE_FILE_FAILURE | A JUNOS process could not perform the indicated operation on the indicated SNMP engine data file. |
LIBJNX_SOCKET_FAILURE | Various system processes use Transmission Control Protocol (TCP), User Datagram Protocol (UDP), and Reliable Data Protocol (RDP) sockets. The indicated socket operation failed for the indicated reason. |
LIBMSPRPC_CLIENT_INIT_FAILED | A JUNOS process (mspinfo) could not establish initialization of the RPC client. |
LIBMSPRPC_CLIENT_KCOM_FAILED | A JUNOS process (mspinfo) could not establish initialization of the kcom subsystem. |
LIBMSPRPC_CLIENT_KCOM_NO_IF | A JUNOS process (mspinfo) could not find any configured and active extension-provider interfaces. |
LIBMSPRPC_CLIENT_NO_CONNECTION | Remote execution of the command given from the Routing Engine to the PIC. The Routing Engine cannot connect to the PIC. |
LIBMSPRPC_CLIENT_NO_REPLY | Remote execution of the command given from the Routing Engine to the PIC failed. There was no reply from the PIC. |
LIBMSPRPC_CLIENT_PIC_DOWN | Remote execution of the command given from the Routing Engine to the PIC failed. The PIC is down. |
LIBMSPRPC_CLIENT_WRONG_OUTPUT | Remote execution of the command given from the Routing Engine to the PIC failed. The PIC returned unexpected output. |
LIBSERVICED_CLIENT_CONNECTION . | An attempt to establish a client connection failed. |
LIBSERVICED_SOCKET_BIND | An attempt to bind a server socket for receiving client requests failed. |
LIBSERVICED_SOCKET_PRIVATIZE | An attempt to attach a socket to the management routing instance for communication between the Routing Engine and GGSN-C PICs failed. |
LICENSE_EXPIRED | A time-based license for a feature has expired. The feature will remain inactive until a new license is installed. |
LICENSE_GRACE_PERIOD_APPROACHING | The grace period for a licensable feature is about to expire. Unless a new license is installed, the feature will become inactive after the grace period expires. |
LICENSE_GRACE_PERIOD_EXCEEDED | The grace period for a scale license is about to expire. Unless the scale license is upgraded, the license will scale back to the licensed limit after the grace period expires. |
LICENSE_GRACE_PERIOD_EXPIRED | The grace period for a licensable feature has expired. Strict license enforcement will remain active until a new license is installed. |
LICENSE_NEARING_EXPIRY | A time-based license for a feature is about to expire. Unless a new license is installed, the feature will become inactive after the license expires. |
LPDFD_DYN_PDB_OPEN_FAILED | The local policy decision function process (lpdfd) failed to open the profile database. |
LPDFD_DYN_REGISTER_FAILED | The local policy decision function process (lpdfd) failed to register with the dynamic configuration subsystem. |
LPDFD_DYN_SDB_OPEN_FAILED | The local policy decision function process (lpdfd) failed to open the session database. |
LPDFD_PCONN_SERVER | The local policy decision function process (lpdfd) pconn server failed to initialize. |
LPDFD_RTSOCK_OPEN_FAILURE | The Local Policy Decision Function (LPDF) services process could not successfully open a routing socket to the kernel. The error string accompanying this log entry indicates the specific error. |
MIB2D_RTSLIB_READ_FAILURE | A call to the indicated function in the routing socket library failed during the indicated operation on the indicated object. |
MIB2D_SNMP_INDEX_ASSIGN | MIB2D cannot assign an SNMP index for each interface. |
MIB2D_SNMP_INDEX_DUPLICATE | The first interface name was assigned the same SNMP index as the second interface name. |
MIB2D_SNMP_INDEX_UPDATE_STAT | MIB2D cannot get the status of the SNMP index file. |
MIB2D_SNMP_INDEX_WRITE | MIB2D cannot write to a file containing all the indices. |
PFE Crash | Any PFE board crash that occurs in conjunction with a system exception message. |
PFE: ASIC Initialization Error | Any PFE ASIC initialization error that occurs in conjunction with a system exception message, such as: router-name fpc5 CMG: Fatal ASIC initialization error, Offlining FPC |
PFE: CMRFEB: Fatal HSL2 errors for FPC | A switching board (e.g., FEB) is reporting a bad fabric connection to an FPC. |
PFE: DFW: jtree cutover failed | The firewall filter configuration cannot be applied due to insufficient amount of contiguous memory on the SRAM. |
PFE: imq_stream_disable_stream | The I-chip wedge issue described in PR 277853, which can lead to packet corruption or packet loss. The Event trigger contains the string: imq_stream_disable_stream. |
PFE: Multiple Correctable ECC | The PFE board is reporting multiple correctable ECC memory errors. |
PFE: Multiple UnCorrectable EC. | The PFE board is reporting multiple uncorrectable ECC memory errors. |
PFE: Packet drop in Ichip | The Ichip packet writer drop counter is incrementing, possibly indicating packet drops which may, but not necessarily, be due to a faulty switching board. |
PFE: RT: Failed prefix change | These messages indicate that the RE is trying to delete routes from the PFE, but it can't because the routes aren't there. This usually means the PFE has run out of memory. For example, if you bring up many BGP peers, the number of routes the RE can hold may surpass the number the PFE can hold. In this case, the PFE runs out of memory and can't add the routes. Later, when the RE tries to remove the routes, the prefix it’s looking for is unknown. |
PFE: SDRAM ECC Error | Any PFE SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name fpc0 ADPC: detected 1 DDR SDRAM Single-bit ECC errors in the last 30 seconds. |
PFE: SRAM Parity Error | Any PFE SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name ssb CCHIP: %PFE-3: SRAM parity error 0x80000 bank 0x1 |
PFE: TOXIC SFP | The PFE error is due to a toxic SFP. |
PFE: SDRAM ECC Error | Any PFE SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name fpc0 ADPC: detected 1 DDR SDRAM Single-bit ECC errors in the last 30 seconds |
PFE: SRAM Parity Error | Any PFE SDRAM ECC error that occurs in conjunction with a system exception message, for example: router-name ssb CCHIP: %PFE-3: SRAM parity error 0x80000 bank 0x1 |
PPMD_ASSERT_SOFT | The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As the ppmd process with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. The ppmd process created a diagnostic core file for analysis by technical support personnel and continued to run. |
PPMD_READ_ERROR | The source code for the periodic package management process (ppmd) includes internal self-consistency checks. As the ppmd process with the indicated process ID (PID) executed the binary compiled from the indicated source file, a check failed at the indicated line number in the file. The ppmd process created a diagnostic core file for analysis by technical support personnel and continued to run. |
problem-event-l2cacheerror | The PFE component is reporting that L2 Cache Single-bit ECC errors were detected in the last 30 seconds. If the problem persists, this is likely to result in a component crash or failure. |
problem-event-ichipfcheck | The FPC is reporting a bad fabric connection to one or more destinations. Another FPC is likely to be causing the packet corruption. |
problem-event-jbuserror | An error occurred on the FPC control bus used for packet memory allocation. |
problem-event-lchipcrc | The outbound FPC is reporting a corrupt packet received on the Nchip-to-Lchip interface. Another FPC is likely to be causing the packet corruption. |
problem-event-nfabcrcerror | The fabric connection to the ingress FPC is reporting a bad connection. |
RDD_EVLIB_CREATE_FAILURE | The redundant interfaces process (rdd) could not create a context used for handling all asynchronous events (such as timers and message availability). |
RMON_EVENT_cfeb_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on CFEB. |
RMON_EVENT_cfeb_high_heap_utilization | Remote monitoring event reporting high heap utilization on CFEB. |
RMON_EVENT_feb_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on FEB. |
RMON_EVENT_feb_high_heap_utilization | Remote monitoring event reporting high heap utilization on FEB. |
RMON_EVENT_fpc_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on FPC. |
RMON_EVENT_fpc_high_heap_utilization | Remote monitoring event reporting high heap utilization on FPC. |
RMON_EVENT_fwdd_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on FWDD. |
RMON_EVENT_fwdd_high_heap_utilization | Remote monitoring event reporting high heap utilization on FWDD. |
RMON_EVENT_pfe_aged_notification | Remote monitoring event reporting PFE notification: aged packets. |
RMON_EVENT_pfe_corrupt_notification | Remote monitoring event reporting PFE notification: corrupt packets. |
RMON_EVENT_pfe_dmafail_notification | Remote monitoring event reporting 'PFE notification: DMAfail packets. |
RMON_EVENT_pfe_getfail_notification | Remote monitoring event reporting PFE notification: Getfail packets. |
RMON_EVENT_pfe_giant_notification | Remote monitoring event reporting PFE notification: Giant packets. |
RMON_EVENT_pfe_illegal_notification | Remote monitoring event reporting PFE notification: Illegal packets. |
RMON_EVENT_re_high_dram_utilization | Remote monitoring event reporting high DRAM CPU utilization on RE. |
RMON_EVENT_sfm_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on SFM. |
RMON_EVENT_sfm_high_heap_utilization | Remote monitoring event reporting high heap utilization on SFM. |
RMON_EVENT_spmb_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on SPMB. |
RMON_EVENT_spmb_high_heap_utilization | Remote monitoring event reporting high heap utilization on SPMB. |
RMON_EVENT_ssb_high_buffer_utilization | Remote monitoring event reporting high buffer utilization on SSB. |
RMON_EVENT_ssb_high_heap_utilization | Remote monitoring event reporting high heap utilization on SSB. |
RPD_ABORT | The routing protocol process (rpd) terminated because of an internal error. |
RPD_ACTIVE_TERMINATE | After receiving multiple termination requests, the routing protocol process (rpd) exited without performing the indicated cleanup tasks. |
RPD_ASSERT | The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, causing the instance of rpd that was using the indicated binary and had the indicated process ID (PID) to terminate. The process created a diagnostic core dump for analysis by technical support personnel. |
RPD_ASSERT_SOFT | The source code for the routing protocol process (rpd) includes internal self-consistency checks. A check failed at the indicated line number in the indicated source file, but the instance of rpd that was using the indicated binary and had the indicated process ID (PID) continued running. The process created a diagnostic core dump for analysis by technical support personnel. |
RPD_BGP_NEIGHBOR_STATE_CHANGED | During the BGP negotiation with the local router, the state of the indicated BGP neighbor (peer) changed as indicated. The ESTABLISHED state is the final state in the neighbor negotiation. |
RPD_DYN_CFG_BAD_REQ_OPCODE | The routing protocol process (rpd) received a dynamic configuration request with an unexpected operation code. |
RPD_DYN_CFG_BUSY_SIGNAL_FAILED | The routing protocol process (rpd) failed to notify dynamic configuration clients about its availability to process dynamic configuration requests. |
RPD_DYN_CFG_GET_PROFILE_FAILED | The routing protocol process (rpd) tried to load a profile from the database and failed. |
RPD_DYN_CFG_GET_PROF_NAME_FAILED | The routing protocol process (rpd) tried to get the profile name from the session snapshot and failed. |
RPD_DYN_CFG_GET_SES_STATE_FAILED | The routing protocol process (rpd) failed to get the session state from the session snapshot. |
RPD_DYN_CFG_GET_SNAPSHOT_FAILED | The routing protocol process (rpd) tried to load client session data from the database and failed. |
RPD_DYN_CFG_PDB_CLOSE_FAILED | The routing protocol process (rpd) tried to close the profile database and failed. |
RPD_DYN_CFG_PDB_OPEN_FAILED | The routing protocol process (rpd) tried to open the profile database and failed. |
RPD_DYN_CFG_PROCESSING_FAILED | The routing protocol process (rpd) tried to process dynamic configuration and failed. |
RPD_DYN_CFG_REGISTER_FAILED | The routing protocol process (rpd) tried to register with the dynamic configuration subsystem and failed. |
RPD_DYN_CFG_REQUEST_ACK_FAILED | The routing protocol process (rpd) tried to ACK a dynamic configuration request and failed. |
RPD_DYN_CFG_SCHEMA_OPEN_FAILED | The routing protocol process (rpd) tried to open the configuration schema and failed. |
RPD_DYN_CFG_SDB_CLOSE_FAILED | The routing protocol process (rpd) tried to close the session database and failed. |
RPD_DYN_CFG_SDB_OPEN_FAILED | The routing protocol process (rpd) tried to open the session database and failed. |
RPD_DYN_CFG_SES_RECOVERY_FAILED | The routing protocol process (rpd) tried to recover a session and failed. |
RPD_ISIS_ADJDOWN | An IS-IS adjacency with the indicated neighboring router was terminated. The local router will no longer exchange routing information with, or direct traffic to, the neighboring router. |
RPD_ISIS_LSPCKSUM | The indicated IS-IS informational link-state PDU (LSP) failed an internal checksum validity test, implying that it was corrupted. |
RPD_ISIS_OVERLOAD | The IS-IS link-state database is full and no additional memory can be allocated for it. |
RPD_KRT_Q_RETRIES | The routing protocol process (rpd) attempted to update the kernel for the indicated times and failed. It will continue retrying. |
RPD_LMP_UNEXPECTED_OPCODE | The routing protocol process (rpd) received the indicated type of message, which had the indicated invalid operation code. |
RPD_OS_MEMHIGH | The routing protocol process (rpd) is using the indicated amount and percentage of Routing Engine memory, which is considered excessive. |
RPD_OSPF_NBRDOWN | An OSPF adjacency with the indicated neighboring router was terminated. The local router will no longer exchange routing information with, or direct traffic to, the neighboring router. |
RPD_RSVP_NBRDOWN | The RSVP neighbor to the indicated address was terminated. |
RPD_RT_ERROR | A route in the routing table was found to be in an unrecoverable error state. |
RPD_TASK_FORK | The routing protocol process failed to create the indicated child process. |
RT_SCREEN_TCP | A TCP attack category. |
RT_SCREEN_UDP | A UDP attack category. |
RTPERF_CPU_THRESHOLD_EXCEEDED | The PFE CPU threshold has been exceeded. |
RTLOGD_DAEMONIZE_FAILED | The JSR log daemon could not create a version of itself to run in the background as a daemon. |
RTLOGD_EVLIB_FAILURE | The JSR log daemon called the indicated event library function. The function failed with the indicated error. |
RTLOGD_GET_TNP_ADDRESS_FAILED | JSR log daemon failed to determine local TNP address used to receive JSR log. |
RTLOGD_LOG_BIND_ERROR | The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to connect to the forwarder. |
RTLOGD_LOG_READ_ENABLE_ERROR | The JSR log daemon received the JSR log from a JSR log forwarder. The JSR log daemon failed to enable the reading of the JSR log from the forwarder. |
RTLOGD_LOG_READ_ERROR | The JSR log daemon relayed the JSR logs from the dataplane to the system event daemon for logging. The JSR log daemon failed to read JSR logs for the indicated reason. |
SAVAL_RTSOCK_FAILURE | The MAC SA Validate system process (jsavald) experienced the indicated error with a routing socket. |
SDXD_DAEMONIZE_FAIL | The Service Deployment System process (sdxd) could not create a version of itself to run in the background as a daemon. |
SERVICED_CLIENT_DISCONNECTED | The remote client closed the connection or stopped responding. |
SERVICED_CLIENT_ERROR | An I/O error caused the termination of a connection with an interface client. |
SERVICED_COMMAND_FAILED | An error caused a command being executed on an interface client to be cancelled. |
SERVICED_CONNECTION_ERROR | The remote client closed the connection when data was expected. |
SERVICED_EVENT_FAILED | The Services PICs process (serviced) could not continue processing a task because a call to a function in the event library failed. |
SERVICED_INIT_FAILED | One of the steps in the initialization sequence for the Services PICs process (serviced) failed. |
SERVICED_INTERNAL_INCONSISTENCY | An internal consistency check failed due to a mismatch between expected and received values for the specified object. |
SERVICED_MALLOC_FAILURE | The Services PICs process (serviced) could not allocate the number of bytes needed to hold the indicated object. |
SERVICED_PID_FILE_LOCK | As a part of normal startup, the Services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not lock the file. |
SERVICED_PID_FILE_UPDATE | As a part of normal startup, the Services PICs process (serviced) locks a file and writes its process ID (PID) into it. It could not write to the file. |
SERVICED_NETWORK_FAILURE | An attempt to use the indicated network library call failed with an error. |
SERVICED_RTSOCK_SEQUENCE | The Services PICs process (serviced) encountered a sequence error while receiving messages from the routing socket library. |
SERVICED_SIGNAL_HANDLER | As a part of normal functioning, the Services PICs process (serviced) attempted to initialize a signal-handling function. Part of the initialization failed with an error. |
SERVICED_STDLIB_FAILURE | The value returned by a call to a library function indicated that an error occurred. |
SERVICED_SOCKET_CREATE | An attempt by the Services PICs process (serviced) to create a new socket for communication with an interface client failed with an error. |
SERVICED_SOCKET_IO | A call to a socket library function indicated that an error occurred while attempting to perform I/O. |
SERVICED_SOCKET_OPTION | An attempt to set an option on a socket failed. |
SPD_DAEMONIZE_FAILED | The adaptive services process (spd) could not create a version of itself to run in the background as a daemon. |
SNMP_RTSLIB_FAILURE | A call to the indicated function in the routing socket library failed with the indicated error. |
SNMPD_FILE_FAILURE | The Simple Network Management Protocol (SNMP) agent process (snmpd) could not access the indicated file. |
SNMPD_RMONFILE_FAILURE | The indicated operation failed on the indicated remote monitoring (RMON) data file. |
SNMPD_SEND_FAILURE | The Simple Network Management Protocol (SNMP) agent process (snmpd) could not send either a protocol data unit (PDU) to the User Datagram Protocol (UDP) or a message to a subagent. |
SNMPD_SOCKET_FATAL_FAILURE | The Simple Network Management Protocol (SNMP) agent process (snmpd) uses sockets for communication with subagents. The process exited after a socket operation, such as creation or removal, failed. |
SNMPD_SUBAGENT_NO_RESOURCES | The Simple Network Management Protocol (SNMP) agent process (snmpd) uses certain resources for communication with subagents. However, the resources were not available for communication with the indicated subagent. |
SNMP_PATRICIA_ERROR | A call to a Patricia tree library function returns an error. |
SPD_EVLIB_CREATE_FAILURE | The adaptive services process (spd) could not create a context used for handling all asynchronous events (such as timers and message availability). |
SPD_GEN_NUM_FAIL | The adaptive services process (spd) attempted to initialize the generation-number for the service sets. However, the memory allocation failed. |
SYSTEM: writing kernel | A kernel crash event. A writing kernel message is captured after the router reboots. |
SYSTEM: Alarm set: Temp Too Warm | The system is indicating that the sensor on an EX FPC is exceeding the temperature threshold. |
TASK_OS_MEMHIGH | The process is using the indicated amount and percentage of Routing Engine memory, which is considered excessive. |
TASK_SYSTEM | A system call made by this process failed. |
UI_DBASE_REBUILD_FAILED | The management process (mgd) could not rebuild the configuration database file. |
UI_DBASE_REBUILD_SCHEMA_FAILED | The management process (mgd) could not rebuild the schema for the configuration database. |
UI_DBASE_REOPEN_FAILED | After rebuilding the schema file for the configuration database, the management process (mgd) closes the file and reopens it in read-only mode to prevent corruption. It could not reopen the file. |
UI_SCHEMA_SEQUENCE_ERROR | The JUNOS user interface schema file records all CLI commands and configuration statements available in the JUNOS software. The management process (mgd) rebuilds the schema as necessary to be compatible with the JUNOS software installed on the routing platform. A sequence number in the schema acts as a checksum that represents its content and format. A JUNOS process attempted to access the schema but determined that the schema's sequence number means that it is incompatible with the process. |
UTMD_MALLOC_FAILURE | The example process (utmd) could not allocate memory for a resource, possibly due to a lack of memory. |
UTMD_SSAMLIB_FAILURE | The example process (utmd) encountered an error while calling a function or from a callback of the ssamlib library. |
WEB_ALLOCATE | The Web management process (httpd) could not allocate the indicated amount of memory, for the indicated reason. |
WEB_MEMORY_ALLOC | The Web management process (httpd) could not allocate the indicated number of bytes of memory, for the indicated reason. |
WEB_MGD_LISTEN_ERROR | The Web management process could not open the MGD listening socket. |
WEBFILTER_CACHE_NOT_ENABLED | The category cache Web filter failed to enable. |
WEBFILTER_REQUEST_NOT_CHECKED | The Web filtering failed to check a Web request. |
WEB_SOCKET | The Web management process (httpd) could not create a socket, for the indicated reason. |