Examples: Interface Naming
This section provides examples of naming interfaces. For an illustration of where slots, PICs, and ports are located, see Figure 2.
![]()
For an FPC in slot 1 with two OC3 SONET/SDH PICs in PIC positions 0 and 1, each PIC with two ports uses the following names:
so-1/0/0.0so-1/0/1.0so-1/1/0.0so-1/1/1.0An OC48 SONET/SDH FPC in slot 1 and in concatenated mode appears as a single FPC with a single PIC, which has a single port. If this interface has a single logical unit, it has the following name:
so-1/0/0.0An OC48 SONET/SDH FPC in slot 1 and in channelized mode has a number for each channel. For example:
so-1/0/0:0so-1/0/0:1For an FPC in slot 1 with a Channelized OC12 PIC in PIC position 2, the DS3 channels have the following names:
t3-1/2/0:0t3-1/2/0:1t3-1/2/0:2...t3-1/2/0:11For an FPC in slot 1 with four OC12 ATM PICs (the FPC is fully populated), the four PICs, each with a single port and a single logical unit, have the following names:
at-1/0/0.0at-1/1/0.0at-1/2/0.0at-1/3/0.0In a routing matrix on the T640 routing node labeled
lcc1, for an FPC in slot 5 with four SONET OC192 PICs, the four PICs, each with a single port and a single logical unit, have the following names:so-13/0/0.0so-13/1/0.0so-13/2/0.0so-13/3/0.0For an FPC in slot 1 with one 4-port BRI interface card, port 4 has the following name:
br-1/0/4The first B channel, the second B channel, and the control channel have the following names:
bc-1/0/4:1bc-1/0/4:2dc-1/0/4:0