Configuring Aggregated Ethernet Minimum Links
On aggregated Ethernet interfaces, you can configure the minimum number of links that must be up for the bundle as a whole to be labeled up. By default, only one link must be up for the bundle to be labeled up.
To configure the minimum number of links, include the
minimum-linksstatement at the[edit interfacesinterface-nameaggregated-ether-options]hierarchy level:[edit interfacesinterface-nameaggregated-ether-options]minimum-linksnumber;The number can be from 1 through 8 for Ethernet interfaces on a T-series platform or TX Matrix routing platform. (The maximum number of links supported in an aggregate is eight.)