[Contents] [Prev] [Next] [Index] [Report an Error]


Configuring Aggregated Ethernet Minimum Links

On aggregated Ethernet interfaces, you can configure the minimum number of links that must be up for the bundle as a whole to be labeled up. By default, only one link must be up for the bundle to be labeled up.

To configure the minimum number of links, include the minimum-links statement at the [edit interfaces interface-name aggregated-ether-options] hierarchy level:

[edit interfaces interface-name aggregated-ether-options]
minimum-links number; 

The number can be from 1 through 8 for Ethernet interfaces on a T-series platform or TX Matrix routing platform. (The maximum number of links supported in an aggregate is eight.)


[Contents] [Prev] [Next] [Index] [Report an Error]