Option: Configuring System Logging
By default, control protocol activity is logged as a separate system log facility,
dfc. To modify the filename or level at which control protocol activity is recorded, include the following statements at the[edit syslog]hierarchy level:[edit syslog]file dfc.log {dfc any;}To cancel logging, include the
no-syslogstatement at the [edit services dynamic-flow-capturecapture-groupclient-namecontrol-sourceidentifier] hierarchy level:[edit servicesdynamic-flow-capturecapture-groupclient-namecontrol-sourceidentifier]no-syslog;