[Contents] [Prev] [Next] [Index] [Report an Error]


System Requirements

Passive and active flow monitoring applications are supported on the PICs shown in Table 5:


Table 5: Passive and Active Flow Monitoring PIC Support



PIC Type and Service
M5 / M7i
M10 / M10i
M20
M40e
M160
Monitoring Services PIC: passive flow monitoring
No
No
No
Yes
Yes
Monitoring Services PIC: active flow monitoring
Yes
Yes
Yes
Yes
Yes
Monitoring Services II PIC: passive flow monitoring
No
No
No
Yes
Yes
Monitoring Services II PIC: flow collection
No
No
No
Yes
Yes
Adaptive Services PIC:
active flow monitoring
Yes
Yes
Yes
Yes
Yes

Passive Flow Monitoring

To perform passive flow monitoring, your system must meet these minimum requirements:

Active Flow Monitoring

To implement active flow monitoring, your system must meet these minimum requirements:

Table 6, Table 7, and Table 8 describe the specifications for the Monitoring Services PIC, Monitoring Services II PIC, and Adaptive Services PIC.


Table 6: Monitoring Services PIC Specifications

Specification
Description
Physical dimensions
Single-wide PIC that occupies one PIC slot
Connectors
DB-9 diagnostic serial console port
Status LED
One tricolor:
  • Off—The PIC is offline; it is safe to remove it from the chassis
  • Green—The PIC is operating normally
  • Amber—The PIC is initializing
  • Red—The PIC has an error or failure; no further harm can be done by removing it from the chassis
Application LED
One tricolor:
  • Off—Service is not running
  • Green—Service is running under acceptable load
  • Amber—Service is overloaded


Table 7: Monitoring Services II PIC Specifications

Specification
Description
Physical dimensions
Single-wide PIC that occupies one PIC slot
Connectors
N/A
Status LED
One tricolor:
  • Off—The PIC is offline; it is safe to remove it from the chassis
  • Green—The PIC is operating normally
  • Amber—The PIC is initializing
  • Red—The PIC has an error or failure; no further harm can be done by removing it from the chassis
Application LED
One tricolor:
  • Off—cflowd collector is not running
  • Green—cflowd collector is running under acceptable load
  • Amber—cflowd collector is overloaded


Table 8: Adaptive Services PIC Specifications

Specification
Description
Physical dimensions
Single-wide PIC that occupies one PIC slot
Connectors
N/A
Status LED
One tricolor:
  • Off—The PIC is offline; it is safe to remove it from the chassis
  • Green—The PIC is operating normally
  • Amber—The PIC is initializing
  • Red—The PIC has an error or failure; no further harm can be done by removing it from the chassis
Application LED
One tricolor:
  • Off—cflowd collector is not running
  • Green—cflowd collector is running under acceptable load
  • Amber—cflowd collector is overloaded


[Contents] [Prev] [Next] [Index] [Report an Error]