Configure Aggregated Ethernet Minimum Links
On aggregated Ethernet interfaces, you can configure the minimum number of links that must be up for the bundle as a whole to be labeled up. By default, the minimum number of links is
one. The minimum number of links can be from one through eight.To configure the minimum number of links, include the
minimum-linksstatement at the [edit interfacesinterface-nameaggregated-ether-options] hierarchy level:[edit interfacesinterface-nameaggregated-ether-options]minimum-linksnumber;