alarm
Syntax
alarm {
interface-type{
alarm-name(red | yellow | ignore);
}
}Hierarchy Level
Description
Configure the chassis alarms and whether they trigger a red or yellow alarm, or whether they are ignored. Red alarm conditions light the
RED ALARMLED on the router's craft interface and trigger an audible alarm if one is connected to the contact on the craft interface. Yellow alarm conditions light theYELLOW ALARMLED on the router's craft interface and trigger an audible alarm if one is connected to the craft interface.To configure more than one alarm, include multiple
alarm-namelines.Options
alarm-name—Alarm condition. For a list of conditions, see Table 20.
ignore—The specified alarm condition does not set off any alarm.
interface-type—Type of interface on which you are configuring the alarm. It can be one of the following:atm,ethernet,sonet, ort3.
red—The specified alarm condition sets off a red alarm.
yellow—The specified alarm condition sets off a yellow alarm.Usage Guidelines
See Chassis Conditions That Trigger Alarms.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.