e3-options
Syntax
e3-options {
bert-algorithmalgorithm;
bert-error-raterate;
bert-periodseconds;
compatibility-mode(digital-link | kentrox | larscom)<subratevalue>;
fcs(32 | 16);
idle-cycle-flagvalue;
loopback(local | remote);
start-end-flagvalue;
}Hierarchy Level
[edit interfacesinterface-name]Description
Configure E3-specific physical interface properties.
For ATM 1 interfaces, you can configure a subset of E3 options statements.
Options
Each option is explained separately.
Usage Guidelines
See Configure E3 Interfaces and Configure T3 Interfaces.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.See Also