show chassis hardware
Syntax
show chassis hardware <detail> <frus>Description
Display a list of all FPCs and PICs installed in the router chassis, including the hardware version level and serial number.
Options
none—Display information about hardware.
detail—(Optional) Display detailed information about hardware, including memory, hardware version level, serial number, and additional information about memory.
frus—(Optional) Display detailed information about field-replaceable units.Required Privilege Level
Output Fields
Item—Chassis component. Information is displayed about the backplane, power supplies, Routing Engine, maxicab (the connection between the Routing Engine and the backplane, for the M40 router only), SCB, SFP, SSB, SFM, or FEB, MCS and PCG (for the M160 router only), and each FPC and PIC.
Version—Revision level of the chassis component.
Part number—Part number of the chassis component.
Serial number—Serial number of the chassis component. The serial number of the backplane is also the serial number of the router chassis. Use this serial number when you need to contact Juniper Networks Customer Support about the router chassis.
Assb ID—(frusoutput only) Assembly Identification describes what kind of hardware is burned into the IDPROM.
Conn Type—(frusoutput only) Type of connector from a PIC.
Fiber Type—(frusoutput only) Optical fiber type. It can be0x01(single mode),0x02(multimode), or0xff(Not applicable).
Driver Strength—(frusoutput only) Optical strength provided by the PIC. Driver strength determines the range that the laser can drive. It can be one of the following:
Description—Brief description of hardware item.
- For the power supplies, the type of supply.
- For the PICs, the type of PIC.
- For the FPC, the type of FPC. It can be
FPC Type 1,FPC Type 2,FPC Type 3,orFPC Type OC192.- For host, the Routing Engine type.
- For Small Form-factor Pluggable (SFP) modules, the type of fiber. It can be
LX,SXorLH.Sample Output: show chassis hardware (standard, for an M10 router)
user@m10-host>show chassis hardwareHardware inventory:Item Version Part number Serial number DescriptionChassis 1122 M10Midplane REV 1.1 710-001950 S/N AC6626Power supply A Rev 01 740-002497 S/N LC36095 ACPower supply B Rev 01 740-002497 S/N LC36100 ACDisplay REV 1.2 710-001995 S/N AC6656Host 18000005dfb3fb01 teknorFEB REV 01 710-001948 S/N AC6632 Internet Processor IIFPC 0PIC 0 REV 08 750-001072 S/N AB2485 1x G/E, 1000 BASE-SXPIC 1 REV 01 750-000613 S/N AA1048 1x OC-12 SONET, SMIRFPC 1Sample Output: show chassis hardware frus (for an M10 router)
user@m10-host>show chassis hardware frusHardware inventory:Assb Conn Fiber DriverItem Part number ID Type Type Strength DescriptionChassis 0x0505 -- -- -- M10Midplane 710-001950 0x0119 -- -- --Power Supply A 740-002498 0x0407 -- -- -- DCDisplay 710-001995 0x0125 -- -- --Routing Engine 0FEB 0 710-001948 0x0118 -- -- -- Internet Processor IIFPC 0 0x0000 -- -- --PIC 0 750-000603 0x0201 0x02 0x01 0x02 4x OC-3 SONET, SMIRPIC 1 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-002977 0x0209 0x02 0x02 0x03 2x OC-3 ATM, MMFPC 1 0x0000 -- -- --PIC 0 750-003628 0x022c 0x02 0x01 0x04 1x G/E, 1000 BASE-LHPIC 1 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 3 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRLeft Fan 1Left Fan 2Left Fan 3Left Fan 4Sample Output: show chassis hardware (for an M20 router)
user@m20-host>show chassis hardwareHardware inventory:Item Version Part number Serial number DescriptionChassis 20033 M20Backplane REV 07 710-001517 S/N AA7940Power supply B Rev 01 740-001465 S/N 000001 ACDisplay REV 02 710-001519 S/N AA9704Host 0 98000004f8f27501 teknorSSB slot 0 REV 01 710-001951 S/N AD5905 Internet Processor IISSRAM bank 0 REV 01 710-001385 S00480 2 MbytesSSRAM bank 1 REV 01 710-001385 S00490 2 MbytesSSRAM bank 2 REV 01 710-001385 S001:? 2 MbytesSSRAM bank 3 REV 01 710-001385 S00483 2 MbytesSSB slot 1 N/A N/A N/A BackupFPC 1 REV 01 710-001292 S/N AB7528SSRAM REV 01 710-000077 S/N 304209 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N 000603 64 MbytesSDRAM bank 1 REV 01 710-000099 S/N 000414 64 MbytesPIC 0 REV 03 750-000612 S/N AB8433 2x OC-3 ATM, MMPIC 1 REV 01 750-000616 S/N AA1168 1x OC-12 ATM, MMPIC 2 REV 01 750-000613 S/N AA1008 1x OC-12 SONET, SMIRPIC 3 REV 01 750-002501 S/N AD5810 4x E3FPC 2 REV 01 710-001292 S/N AC0119SSRAM REV 01 710-000077 S/N 503241 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N 306835 64 MbytesSDRAM bank 1 REV 01 710-000099 S/N 306832 64 MbytesSample Output: show chassis hardware frus (for an M20 router)
user@m20-host>show chassis hardware frusHardware inventory:Assb Conn Fiber DriverItem Part number ID Type Type Strength DescriptionChassis 0x0503 -- -- -- M20Midplane 710-001517 0x0113 -- -- --Power Supply A 740-001466 0x0405 -- -- -- DCDisplay 710-001519 0x0114 -- -- --Routing Engine 0Routing Engine 1SSB 0 710-007683 0x0163 -- -- -- Internet Processor IISSB 1 710-001951 0x0123 -- -- -- Internet Processor IIFPC 0 710-001292 0x0104 -- -- --PIC 0 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 1 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 2 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRFPC 1 710-001292 0x0104 -- -- --PIC 0 750-000617 0x0203 0x02 0x01 0x02 1x OC-48 SONET, SMIRFPC 2 710-003308 0x013d -- -- -- E-FPCPIC 0 750-002785 0x022c 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 1 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 2 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRFPC 3 710-003308 0x013d -- -- -- E-FPCPIC 0 750-002987 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 1 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 2 750-000603 0x0201 0x02 0x01 0x02 4x OC-3 SONET, SMIRPIC 3 750-000612 0x0209 0x02 0x02 0x03 2x OC-3 ATM, MMRear FanFront Upper FanFront Middle FanFront Bottom FanSample Output: show chassis hardware (for an M40 router)
user@m40-host>show chassis hardwareHardware inventory:Item Version Part number Serial number DescriptionBackplane REV 02 710-000073 S/N AA0053Power supply A Rev 2 740-000235 S/N 000042 DCMaxicab REV X1 710-000229 S/N AAO139Minicab REV X1 710-000482 S/N AA0201Display REV 06 710-000150 S/N AA0905Host cpv5000SCB REV X1 710-000075 S/N AA0158 Internet Processor ISSRAM bank 0 REV 02 710-000077 S/N AA2267 1 MbyteSSRAM bank 1 REV 02 710-000077 S/N AA2270 1 MbyteSSRAM bank 2 REV 02 710-000077 S/N AA2269 1 MbyteSSRAM bank 3 REV 02 710-000077 S/N AA2268 1 MbyteFPC 0 REV 01 710-000175 S/N AA0048SSRAM REV 01 710-000077 S/N AA2333 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N AA2332 64 MbytesSDRAM bank 1 REV X1 710-000099 S/N AA2337 64 MbytesPIC 0 REV 04 750-000613 S/N aa0343 1x OC-12 SONET, SMIRPIC 1 REV 04 750-000613 S/N AA0379 1x OC-12 SONET, SMIRPIC 2 REV 04 750-000613 S/N AA0377 1x OC-12 SONET, SMIRPIC 3 REV 04 750-000613 S/N AA0378 1x TunnelFPC 2 REV 01 710-000175 S/N AA0042SSRAM REV 02 710-000077 S/N AA2288 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N AA2331 64 MbytesSDRAM bank 1 REV 01 710-000099 S/N AA2330 64 MbytesPIC 0 REV X1 750-000603 S/N AA0143 4x OC-3 SONET, SMIRPIC 1 REV X1 750-000615 S/N AA0149 4x OC-3 SONET, MMPIC 2 REV X1 750-000611 S/N AA0148 4x OC-3 SONET, MMPIC 3 REV 04 750-000613 S/N AA0330 1x OC-12 SONET, SMIRFPC 4 REV 01 710-000175 S/N AA0050SSRAM REV 01 710-000077 S/N AA2327 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N AA2329 64 MbytesSDRAM bank 1 REV 01 710-000099 S/N AA2328 64 MbytesPIC 0 REV 04 750-000613 S/N AA0320 1x OC-12 SONET, SMIRPIC 2 REV 05 750-000616 S/N AA1341 1x OC-12 ATM, MMPIC 3 REV 08 750-001072 S/N AB2462 1x G/E, 1000 BASE-SXFPC 5 REV 10 710-000175 S/N AA7663SSRAM REV 01 710-000077 S/N 501590 1 MbyteSDRAM bank 0 REV 01 710-000099 S/N 300949 64 MbytesSDRAM bank 1 REV 01 710-000099 S/N 300868 64 MbytesPIC 1 REV 01 750-001323 S/N AB1670 1x TunnelSample Output: show chassis hardware frus (for an M40 router)
user@m40-host>show chassis hardware frusHardware inventory:Assb Conn Fiber DriverItem Part number ID Type Type Strength DescriptionChassis 0x0502 -- -- -- M40Midplane 710-000073 0x0101 -- -- --Power Supply A 740-000235 0x0402 -- -- -- DCPower Supply B 740-000235 0x0402 -- -- -- DCDisplay 710-000150 0x0103 -- -- --Routing Engine 0SCB 0 710-001838 0x0122 -- -- -- Internet Processor IIFPC 0 710-001292 0x0104 -- -- --PIC 0 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 1 750-002303 0x0214 0x01 0x00 0xff 4x F/E, 100 BASE-TXPIC 2 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-000612 0x0209 0x02 0x02 0x03 2x OC-3 ATM, MMFPC 1 710-001197 0x0104 -- -- --PIC 0 750-000617 0x0203 0x02 0x01 0x02 1x OC-48 SONET, SMIRFPC 2 710-003308 0x013d -- -- -- E-FPCPIC 0 750-002980 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 1 750-002980 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 2 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 3 750-002953 0x0221 0x01 0xff 0xff 4x T1, RJ48FPC 3 710-001292 0x0104 -- -- --PIC 0 750-000617 0x0203 0x02 0x01 0x02 1x OC-48 SONET, SMIRFPC 4 710-001292 0x0104 -- -- --PIC 0 750-000617 0x0203 0x02 0x01 0x02 1x OC-48 SONET, SMIRFPC 5 710-003308 0x013d -- -- -- E-FPCPIC 0 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 1 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 2 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXFPC 6 710-003308 0x013d -- -- -- E-FPCPIC 0 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 1 750-001556 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 2 750-001323 0x020e 0xff 0xff 0xff 1x TunnelPIC 3 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXFPC 7 710-001292 0x0104 -- -- --PIC 0 750-000617 0x0203 0x02 0x01 0x02 1x OC-48 SONET, SMIRTop ImpellerBottom impellerRear Left FanRear Center FanRear Right FanSample Output: show chassis hardware (for an M40e router)
user@m40e-host>show chassis hardwareHardware inventory:Item Version Part number Serial number DescriptionChassis m40eMidplane REV 01 710-005071 AX3671FPM CMB REV 03 710-001642 AR9074FPM Display REV 03 710-001647 AR7331CIP REV 04 710-002649 BB4449PEM 0 Rev 01 740-003787 MC12364 Power Entry ModulePEM 1 Rev 01 740-003787 MC12383 Power Entry ModulePCG 0 REV 07 710-001568 AG1332PCG 1 REV 07 710-001568 AR3789Host 0 3e000007c8176601 PresentMCS 0 REV 11 710-001226 AN5813SFM 0 SPP REV 07 710-001228 AG4676SFM 0 SPR REV 05 710-002189 AE4735 Internet Processor IISFM 1 SPP REV 07 710-001228 AP1347SFM 1 SPR REV 05 710-002189 BE0063 Internet Processor IIFPC 0 REV 02 710-005197 BD9845 M40e-FPC Type 2CPU REV 01 710-004600 BD9504PIC 0 REV 03 750-003737 AY3991 4x G/E, 1000 BASE-SXFPC 1 REV 01 710-005197 BD9842 M40e-FPC Type 2CPU REV 01 710-004600 BB4869PIC 0 REV 07 750-001900 AR8278 1x OC-48 SONET, SMSRFPC 2 REV 02 710-005197 BD9824 M40e-FPC Type 2CPU REV 01 710-004600 BD9531PIC 0 REV 03 750-003737 AY3986 4x G/E, 1000 BASE-SXFPC 4 REV 02 710-005078 BE0664 M40e-FPC Type 1CPU REV 01 710-004600 BD9559PIC 0 REV 03 750-001894 AG7963 1x G/E, 1000 BASE-SXPIC 2 REV 01 750-002575 AF2472 4x OC-3 SONET, SMIRFPC 6 REV 02 710-005078 BE0652 M40e-FPC Type 1CPU REV 01 710-004600 BD9607PIC 0 REV 02 750-002911 AN2286 4x F/E, 100 BASE-TXPIC 2 REV 01 750-002577 AP6345 4x OC-3 SONET, MMSample Output: show chassis hardware (for an M160 router)
user@m160-host>show chassis hardwareItem Version Part number Serial number DescriptionChassis 101 M160Midplane REV 02 710-001245 S/N AB4107FPM CMB REV 01 710-001642 S/N AA2911FPM Display REV 01 710-001647 S/N AA2999CIP REV 02 710-001593 S/N AA9563PEM 0 Rev 01 740-001243 S/N KJ35769 DCPEM 1 Rev 01 740-001243 S/N KJ35765 DCPCG 0 REV 01 710-001568 S/N AA9794PCG 1 REV 01 710-001568 S/N AA9804Host 1 da000004f8d57001 teknorMCS 1 REV 03 710-001226 S/N AA9777SFM 0 SPP REV 04 710-001228 S/N AA2975SFM 0 SPR REV 02 710-001224 S/N AA9838 Internet Processor ISFM 1 SPP REV 04 710-001228 S/N AA2860SFM 1 SPR REV 01 710-001224 S/N AB0139 Internet Processor IFPC 0 REV 03 710-001255 S/N AA9806 FPC Type 1CPU REV 02 710-001217 S/N AA9590PIC 1 REV 05 750-000616 S/N AA1527 1x OC-12 ATM, MMPIC 2 REV 05 750-000616 S/N AA1535 1x OC-12 ATM, MMPIC 3 REV 01 750-000616 S/N AA1519 1x OC-12 ATM, MMFPC 1 REV 02 710-001611 S/N AA9523 FPC Type 2CPU REV 02 710-001217 S/N AA9571PIC 0 REV 03 750-001900 S/N AA9626 1x STM-16 SDH, SMIRPIC 1 REV 01 710-002381 S/N AD3633 2x G/E, 1000 BASE-SXFPC 2 FPC Type OC192CPU REV 03 710-001217 S/N AB3329PIC 0 REV 01 1x OC-192 SM SR-2Sample Output: show chassis hardware frus (for an M160 router)
user@m160-host>show chassis hardware frusHardware inventory:Assb Conn Fiber DriverItem Part number ID Type Type Strength DescriptionChassis 0x0504 -- -- -- M160Midplane 710-001245 0x0108 -- -- --FPM CMB 710-001642 0x0111 -- -- --FPM Display 710-001647 0x0110 -- -- --CIP 710-001593 0x0116 -- -- --PEM 0 740-001243 0x0405 -- -- -- DCPEM 1 740-001243 0x0405 -- -- -- DCPCG 0 710-001568 0x010d -- -- --PCG 1 710-001568 0x010d -- -- --Routing Engine 0Routing Engine 1MCS 0 710-001226 0x0109 -- -- --MCS 1 710-001226 0x0109 -- -- --SFM 0 710-001228 0x010e -- -- --SFM 1 710-001228 0x010e -- -- --SFM 2 710-001228 0x010e -- -- --SFM 3 710-001228 0x010e -- -- --FPC 0 710-003950 0x013f -- -- -- E-FPC Type 2PIC 0 750-001900 0x0211 0x02 0x01 0x02 1x OC-48 SONET, SMIRPIC 1 710-002381 0x021c 0x01 0x02 0x03 2x G/E, 1000 BASE-SXPIC 2 750-001900 0x0211 0x02 0x01 0x03 1x OC-48 SONET, SMSRPIC 3 750-001900 0x0211 0x02 0x01 0x02 1x OC-48 SONET, SMIRFPC 1 710-003307 0x013e -- -- -- E-FPC Type 1PIC 0 750-001072 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 1 750-002785 0x022c 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 2 750-001894 0x0205 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 3 750-003141 0x022c 0x02 0x02 0x03 1x G/E, 1000 BASE-SXFPC 2 710-001255 0x010b -- -- -- FPC Type 1PIC 0 750-003141 0x022c 0x02 0x02 0x03 1x G/E, 1000 BASE-SXPIC 1 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRPIC 3 750-001887 0x0205 0x02 0x01 0x01 1x G/E, 1000 BASE-LXFPC 3 710-003950 0x013f -- -- -- E-FPC Type 2PIC 0 750-002510 0x021c 0x02 0x02 0x03 2x G/E, 1000 BASE-SXPIC 1 750-001900 0x0211 0x02 0x01 0x03 1x OC-48 SONET, SMSRPIC 2 750-002510 0x021c 0x02 0x02 0x03 2x G/E, 1000 BASE-SXPIC 3 750-001850 0x0212 0xff 0xff 0xff 1x TunnelFPC 4 710-003947 0x013e -- -- -- E-FPC Type 1PIC 0 750-003034 0x0201 0x02 0x01 0x02 4x OC-3 SONET, SMIRPIC 1 750-003629 0x022c 0x02 0x01 0x04 1x G/E, 1000 BASE-LHPIC 2 750-005719 0x022b 0x02 0x02 0x03 1x OC-12 ATM-II, MMPIC 3 750-001555 0x0202 0x02 0x02 0x03 1x OC-12 SONET, MMFPC 5 710-001255 0x010b -- -- -- FPC Type 1PIC 1 750-002911 0x0214 0x01 0x00 0xff 4x F/E, 100 BASE-TXPIC 2 750-003104 0x0235 0x00 0xff 0xff 4x T3 ATMPIC 3 750-000613 0x0202 0x02 0x01 0x02 1x OC-12 SONET, SMIRFPC 6 710-003950 0x013f -- -- -- E-FPC Type 2PIC 0 750-001902 0x021d 0x02 0x02 0x03 4x OC-12 SONET, MMPIC 2 750-003168 0x0238 0xff 0xff 0xff 48x FE, 100 BASE-TXPIC 3 750-001901 0x021d 0x02 0x01 0x02 4x OC-12 SONET, SMIRFPC 7 710-003958 0x0140 -- -- -- E-FPC Type OC192PIC 0 750-004864 0x0231 0x02 0x01 0x03 1x OC-192 SM SR2-BRear Bottom BlowerRear Top BlowerFront Top BlowerFan TraySample Output: show chassis hardware detail
user@host>show chassis hardware detailHardware inventory:Item Version Part number Serial number DescriptionChassis 101 M160Midplane REV 02 710-001245 S/N AB4107FPM CMB REV 01 710-001642 S/N AA2911FPM Display REV 01 710-001647 S/N AA2999CIP REV 02 710-001593 S/N AA9563PEM 0 Rev 01 740-001243 S/N KJ35769 DCPEM 1 Rev 01 740-001243 S/N KJ35765 DCPCG 0 REV 01 710-001568 S/N AA9794PCG 1 REV 01 710-001568 S/N AA9804Host 1 da000004f8d57001 teknorMCS 1 REV 03 710-001226 S/N AA9777SFM 0 SPP REV 04 710-001228 S/N AA2975SFM 0 SPR REV 02 710-001224 S/N AA9838 Internet Processor ISSRAM bank 0 REV 01 710-000077 S/N 306456 1 MbyteSSRAM bank 1 REV 01 710-000077 S/N 306474 1 MbyteSSRAM bank 2 REV 01 710-000077 S/N 306388 1 MbyteSSRAM bank 3 REV 01 710-000077 S/N 306392 1 MbyteSFM 1 SPP REV 04 710-001228 S/N AA2860SFM 1 SPR REV 01 710-001224 S/N AB0139 Internet Processor ISSRAM bank 0 REV 01 710-000077 S/N 302917 1 MbyteSSRAM bank 1 REV 01 710-000077 S/N 302662 1 MbyteSSRAM bank 2 REV 01 710-000077 S/N 302593 1 MbyteSSRAM bank 3 REV 01 710-000077 S/N 100160 1 MbyteFPC 0 REV 03 710-001255 S/N AA9806 FPC Type 1CPU REV 02 710-001217 S/N AA9590SSRAM REV 01 710-000077 S/N 302836 1 MbyteSDRAM 0 REV 01 710-001196 S00141 32 MbytesSDRAM 1 REV 01 710-001196 S0010; 32 MbytesSSRAM REV 01 710-000077 S/N 302633 1 MbyteSDRAM 0 REV 01 710-001196 S00143 32 MbytesSDRAM 1 REV 01 710-001196 S00115 32 MbytesSSRAM REV 01 710-000077 S/N 302952 1 MbyteSDRAM 0 REV 01 710-001196 S00135 32 MbytesSDRAM 1 REV 01 710-001196 S001=3 32 MbytesSSRAM REV 01 710-000077 S/N 302892 1 MbyteSDRAM 0 REV 01 710-001196 S000?6 32 MbytesSDRAM 1 REV 01 710-001196 S001=5 32 MbytesPIC 1 REV 05 750-000616 S/N AA1527 1x OC-12 ATM, MMPIC 2 REV 05 750-000616 S/N AA1535 1x OC-12 ATM, MMPIC 3 REV 01 750-000616 S/N AA1519 1x OC-12 ATM, MMFPC 1 REV 02 710-001611 S/N AA9523 FPC Type 2CPU REV 02 710-001217 S/N AA9571SSRAM REV 01 710-000077 S/N 306340 1 MbyteSDRAM 0 REV 01 710-001196 S00012 32 MbytesSDRAM 1 REV 01 710-001196 S0001? 32 MbytesSSRAM REV 01 710-000077 S/N 306454 1 MbyteSDRAM 0 REV 01 710-001196 S00028 32 MbytesSDRAM 1 REV 01 710-001196 S0002? 32 MbytesSSRAM REV 01 710-000077 S/N 306492 1 MbyteSDRAM 0 REV 01 710-001196 S00015 32 MbytesSDRAM 1 REV 01 710-001196 S00031 32 MbytesSSRAM REV 01 710-000077 S/N 306363 1 MbyteSDRAM 0 REV 01 710-001196 S00013 32 MbytesSDRAM 1 REV 01 710-001196 S00032 32 MbytesPIC 0 REV 03 750-001900 S/N AA9626 1x STM-16 SDH, SMIRPIC 1 REV 01 710-002381 S/N AD3633 2x G/E, 1000 BASE-SXFPC 2 FPC Type OC192CPU REV 03 710-001217 S/N AB3329SSRAM REV 01 710-000077 S/N 306466 1 MbyteSDRAM 0 710-001196 32 MbytesSDRAM 1 710-001196 32 MbytesSSRAM REV 01 710-000077 S/N 303919 1 MbyteSDRAM 0 710-001196 32 MbytesSDRAM 1 710-001196 32 MbytesSSRAM REV 01 710-000077 S/N 306476 1 MbyteSDRAM 0 32 MbytesSDRAM 1 32 MbytesSSRAM REV 01 710-000077 S/N 306409 1 MbyteSDRAM 0 32 MbytesSDRAM 1 32 MbytesPIC 0 REV 01 1x OC-192 SM SR-2