Before you install a chassis or add a new PIM to an existing
chassis, verify that the combination of PIMs and modules (PIMs or
PIMs plus a WXC Integrated Services Module) to be installed does not
exceed the power and heat capacities for that model. Add the low-power
tokens, high-power tokens, and heat tokens required by each PIM, and
compare them to the capacity of the chassis.
Note:
The low power and high power correspond to a specific voltage
for that PIM.
Caution:
Do not install a combination of modules in a single chassis
that exceeds the maximum power and heat capacity of the chassis. If
J-series power management is enabled, PIMs and modules (PIMs or PIMs
plus a WXC Integrated Services Module) that exceed the
maximum power and heat capacity remain offline when the chassis is
powered on.
To verify that the combination of PIMs to be installed in a
chassis does not exceed the power and heat capacities for that model:
Check Table 37 to determine the token values for low-power, high-power,
and heat for each PIM that you plan to install in the chassis.
For all PIMs to be installed in the chassis:
Add the low-power tokens for all PIMs to be installed
in the chassis.
Add the high-power tokens for all PIMs to be installed
in the chassis.
Add the heat dissipation tokens for all PIMs to be installed
in the chassis.
Verify that the total number of low-power tokens,
total number of high-power tokens, and the total number of heat dissipation
tokens do not exceed the maximums permitted for your J-series chassis
as specified in Table 38.
Table 37 shows the
low-power consumption, high-power consumption, and heat dissipation,
represented in non-dimensional tokens, assigned to each J-series PIM.
Table 37: J-series PIM Power Consumption and Heat Dissipation
Name
Model
Number
PIM Abbreviation
in JUNOS CLI
Tokens
Low Power
High Power
Heat
1-Port Gigabit Ethernet uPIM
JXU-SFP-S
1xSFP uPIM
8
–
8
6-Port Gigabit Ethernet uPIM
JXU-6GE-SFP-S
6xSFP uPIM
13
–
13
8-Port Gigabit Ethernet uPIM
JXU-8GE-TX-S
8xGE uPIM
21
–
27
16-Port Gigabit Ethernet uPIM
JXU-16GE-TX-S
16xGE uPIM
38
–
36
1-Port Copper Gigabit Ethernet ePIM
JXE-1GE-TX-S
1xGE Copper
6
–
7
1-Port SFP Gigabit Ethernet ePIM
JXE-1GE-SFP-S
1xGE SFP
4
–
4
Dual-Port Serial PIM
JX-2Serial-S
2xSerial
5
–
6
Dual-Port E1 PIM
JX-2E1-RJ48-S
2xE1
6
–
6
Dual-Port T1 PIM
JX-2T1-RJ48-S
2xT1
6
–
5
Dual-Port Channelized T1/E1/ISDN PRI PIM
JX-2CT1E1-RJ45-S
2xCT1E1 / PRI
5
–
5
E3 PIM (1 port)
JX-1E3-S
1xE3
7
–
7
T3 PIM (also known as DS3)
JX-1DS3-S
1xT3
7
–
7
Dual-Port Fast Ethernet PIM
JX-2FE-TX-S
2xFE
6
1
6
4-Port Fast Ethernet ePIM
JXE-4FE-TX-S
4xFE ePIM
9
–
9
4-Port ISDN BRI S/T PIM
JX-4BRI-S-S
4x BRI S/T
4
–
4
4-Port ISDN BRI U PIM
JX-4BRI-U-S
4x BRI U
4
–
6
ADSL 2/2+ Annex A PIM (1 port, for POTS)
JX-1ADSL-A-S
1x ADSL Annex A
16
2
16
ADSL 2/2+ Annex B PIM (1 port, for ISDN)
JX-1ADSL-B-S
1x ADSL Annex B
16
2
16
G.SHDSL PIM (2-port two-wire mode or 1-port four-wire mode)
JX-2SHDSL-S
2x SHDSL (ATM)
9
–
10
WXC Integrated Services Module
ISM-200–WXC
wan-acceleration
7
37
49
Table 38 lists
the maximum power tokens and maximum heat tokens available for each
model.
Table 38: Maximum Power and Heat Capacities of J-series Models