| Line module label
|
CT1
|
| I/O module label
|
CT1 FULL I/O
|
| Number of I/O ports
|
|
| Software release
|
-
First supported: 1.1.0
-
Final supported: N/A
|
| Description
|
|
| Type |
|
| Capability |
|
| Software features
|
-
See Channelized T1 and E1 Modules for information about the layer
2 and layer 3 protocols and applications that this module combination supports.
|
| Model compatibility
|
-
ERX-7xx models
-
ERX-1410 models
|
| SRP module compatibility
|
|
| Module redundancy support
|
|
| Cables and connectors
|
-
RJ-48C 100–ohm connector
-
Use shielded cables to maintain EMC compliance.
-
The line interface unit supports multiple line buildouts.
-
Signal strength is software controlled.
-
The transmitted signal complies with ANSI T1.102-1993 Digital
Hierarchy - Electrical Interfaces (1999) for cable lengths up to 201 m (660
feet).
-
See E-series Hardware Guide, Chapter 6, Cabling
E-series Routers for more information.
|
| LEDs |
|
| Alarms, errors, and events
|
-
See Monitoring Interfaces in JUNOSe
Physical Layer Configuration Guide, Chapter 3, Configuring CT1 and CE1
Interfaces.
|