For optimum router performance, verify the condition of the SIBs.
On a regular basis:
Observe the status of the SIBs by checking the LEDs on the SIB faceplate. During normal operations:
user@host> show chassis environment sib
State Online - Standby
Temperature 32 degrees C / 89 degrees F
Power
GROUND 0 mV
1.8 V 1789 mV
1.8 V bias 1799 mV
2.5 V 2478 mV
3.3 V 3321 mV
3.3 V bias 3286 mV
5.0 V bias 5001 mV
8.0 V bias 7008 mV
SIB 1 status:
State Online
Temperature 33 degrees C / 91 degrees F
Power
GROUND 0 mV
1.8 V 1807 mV
1.8 V bias 1794 mV
2.5 V 2483 mV
3.3 V 3306 mV
3.3 V bias 3299 mV
5.0 V bias 5008 mV
8.0 V bias 7072 mV
SIB 2 status:
State Online
Temperature 34 degrees C / 93 degrees F
Power
GROUND 0 mV
1.8 V 1802 mV
1.8 V bias 1789 mV
2.5 V 2493 mV
3.3 V 3306 mV
3.3 V bias 3291 mV
5.0 V bias 5001 mV
8.0 V bias 6964 mV
SIB 3 status:
State Online
Temperature 31 degrees C / 87 degrees F
Power
GROUND 0 mV
1.8 V 1794 mV
1.8 V bias 1794 mV
2.5 V 2505 mV
3.3 V 3296 mV
3.3 V bias 3299 mV
5.0 V bias 5020 mV
8.0 V bias 6822 mV
SIB 4 status:
State Online
Temperature 35 degrees C / 95 degrees F
Power
GROUND 0 mV
1.8 V 1802 mV
1.8 V bias 1794 mV
2.5 V 2485 mV
3.3 V 3321 mV
3.3 V bias 3286 mV
5.0 V bias 4976 mV
8.0 V bias 7103 mV
For more information about using the CLI, see the Junos OS System Basics and Services Command Reference
.