For optimum router performance, verify the condition of the SIBs.
On a regular basis:
Observe the status of the SIBs by checking the LEDs on the SIB faceplate. During normal operations:
user@host> show chassis environment sibSIB 0 status:
State Spare
Temperature 45 degrees C / 113 degrees F
Power:
GROUND 0 mV
1.8 V 1794 mV
2.5 V 2446 mV
3.3 V 3291 mV
1.8 V bias 1780 mV
3.3 V bias 3284 mV
5.0 V bias 5003 mV
8.0 V bias 6910 mV
SIB 1 status:
State Online
Temperature 45 degrees C / 113 degrees F
Power:
GROUND 0 mV
1.8 V 1802 mV
2.5 V 2461 mV
3.3 V 3294 mV
1.8 V bias 1782 mV
3.3 V bias 3294 mV
5.0 V bias 5013 mV
8.0 V bias 7057 mV
SIB 2 status:
State Online
Temperature 47 degrees C / 116 degrees F
Power:
GROUND 0 mV
1.8 V 1794 mV
2.5 V 2461 mV
3.3 V 3301 mV
1.8 V bias 1785 mV
3.3 V bias 3296 mV
5.0 V bias 4998 mV
8.0 V bias 7050 mVFor more information about using the CLI, see the Junos OS System Basics and Services Command Reference
.