Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > Maintaining SPCs, IOCs, and Flex IOCs on the SRX5800 Services Gateway
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • SRX5800 Services Gateway I/O Card LEDs
  • SRX5800 Services Gateway Services Processing Card LEDs
  • SRX5800 Services Gateway Craft Interface IOC and SPC LEDs
  • Routine Maintenance Procedures for the SRX5800 Services Gateway
  • Maintaining the Air Filter on the SRX5800 Services Gateway
  • Maintaining the Fan Trays on the SRX5800 Services Gateway
  • Maintaining the SRX5800 Services Gateway Host Subsystem and SCBs
  • Maintaining Port Modules on the SRX5800 Services Gateway
  • Maintaining SRX5800 Services Gateway Network Cables
  • Maintaining SRX5800 Services Gateway Power Supplies
 

Maintaining SPCs, IOCs, and Flex IOCs on the SRX5800 Services Gateway

Purpose

For optimum services gateway performance, verify the condition of the Services Processing Cards (SPCs), I/O Cards (IOCs), and Flex I/O Cards (Flex IOCs). The services gateway can have up to 12 SPCs, IOCs, and Flex IOCs mounted vertically in the card cage at the front of the chassis. To maintain SPCs, IOCs, and Flex IOCs, perform the following procedures regularly:

Action

On a regular basis:

  • Check the LEDs on the craft interface corresponding to each IOC and SPC slot. The green LED labeled OK lights steadily when an IOC or SPC is functioning normally.
  • Check the OK/FAIL LED on the faceplate of each IOC and SPC. For more information, see SRX5800 Services Gateway I/O Card LEDs and SRX5800 Services Gateway Services Processing Card LEDs. If the IOC or SPC detects a failure, it sends an alarm message to the Routing Engine.
  • Issue the CLI show chassis fpc command to check the status of installed IOC and SPCs. As shown in the sample output, the value Online in the column labeled State indicates that the IOC or SPC is functioning normally:
    user@host> show chassis fpc
            Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State       (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online       41      9          0       1024       15         57
      1  Online       43      5          0       1024       16         57
      2  Online       43     11          0       1024       16         57
      3  Empty
      4  Empty
      5  Online       42      6          0       1024       16         57
      6  Empty           
      7  Offline         ---Offlined by cli command---
      8  Empty           
      9  Empty           
     10  Empty           
     11  Empty           
    

    For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:

    user@host> show chassis fpc detail

    Slot 0 information: State Online Temperature 41 degrees C / 105 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-07-10 12:28:33 PDT Uptime: 1 hour, 33 minutes, 52 seconds Slot 1 information: State Online Temperature 43 degrees C / 109 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-07-10 12:28:38 PDT Uptime: 1 hour, 33 minutes, 47 seconds Slot 2 information: State Online Temperature 43 degrees C / 109 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-07-10 12:28:40 PDT Uptime: 1 hour, 33 minutes, 45 seconds Slot 5 information: State Online Temperature 42 degrees C / 107 degrees F Total CPU DRAM 1024 MB Total RLDRAM 256 MB Total DDR DRAM 4096 MB Start time: 2007-07-10 12:28:42 PDT Uptime: 1 hour, 33 minutes, 43 seconds
  • Issue the CLI show chassis fpc pic-status command. The slots are numbered 0 through 5, left to right:
    user@host> show chassis fpc pic-status
    Slot 0   Online       SRX5k DPC 40x 1GE
      PIC 0  Online       10x 1GE RichQ
      PIC 1  Online       10x 1GE RichQ
      PIC 2  Online       10x 1GE RichQ
      PIC 3  Online       10x 1GE RichQ
    Slot 1   Online       SRX5k DPC 40x 1GE
      PIC 0  Online       10x 1GE RichQ
      PIC 1  Online       10x 1GE RichQ
      PIC 2  Online       10x 1GE RichQ
      PIC 3  Online       10x 1GE RichQ
    Slot 2   Online       SRX5k DPC 40x 1GE
      PIC 0  Online       10x 1GE RichQ
      PIC 1  Online       10x 1GE RichQ
      PIC 2  Online       10x 1GE RichQ
      PIC 3  Online       10x 1GE RichQ
    Slot 3   Online       SRX5k SPC
      PIC 0  Offline
      PIC 1  Offline
    Slot 4   Online       SRX5k SPC
      PIC 0  Offline
      PIC 1  Offline
     

    For further description of the output from the command, see the Junos System Basics and Services Command Reference.

 

Related Documentation

  • SRX5800 Services Gateway I/O Card LEDs
  • SRX5800 Services Gateway Services Processing Card LEDs
  • SRX5800 Services Gateway Craft Interface IOC and SPC LEDs
  • Routine Maintenance Procedures for the SRX5800 Services Gateway
  • Maintaining the Air Filter on the SRX5800 Services Gateway
  • Maintaining the Fan Trays on the SRX5800 Services Gateway
  • Maintaining the SRX5800 Services Gateway Host Subsystem and SCBs
  • Maintaining Port Modules on the SRX5800 Services Gateway
  • Maintaining SRX5800 Services Gateway Network Cables
  • Maintaining SRX5800 Services Gateway Power Supplies
 

Published: 2011-03-29

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out