Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > MX Series Routers > MX960 Router Hardware > Maintaining MX960 FPCs
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • MX Series
  • MX960 Flexible PIC Concentrator (FPC) LEDs
  • Troubleshooting the MX960 FPCs
  • Replacing an MX960 FPC
  • Holding an MX960 FPC
  • Storing an MX960 FPC
 

Maintaining MX960 FPCs

Purpose

The router can have one Flexible PIC Concentrator (FPC) installed vertically in two DPC slots at the front of the chassis. For optimum router performance, verify the condition of the FPC.

Action

On a regular basis:

  • Check the LEDs on the craft interface directly above the FPC. The green LED labeled OK lights steadily when an FPC is functioning normally.
  • Check the OK/FAIL LED on the FPC. If the FPC detects a failure, the FPC sends an alarm message to the Routing Engine.
  • Issue the CLI show chassis fpc command to check the status of the installed FPC. As shown in the sample output, the value Online in the column labeled State indicates that the FPC is functioning normally:
    user@host> show chassis fpc
                  Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State    (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online   24      3          0       1024       13         21
      1  Empty
      2  Online   41      9          0       1024       15         57
      3  Online   43      5          0       1024       16         57
      4  Online   43     11          0       1024       16         57
      5  Online   41      9          0       1024       15         57
      6  Online   43      5          0       1024       16         57
      7  Empty
      8  Empty
      9  Empty
      10 Online   24      3          0       1024       13         21
      11 Empty           
     

    For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:

    user@host> show chassis fpc detail
    Slot 0 information:
      State                                 Online    
      Temperature                        24 degrees C / 75 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      128 MB
      Total DDR DRAM                   2048 MB
      Start time:                           2008-12-11 16:53:24 PST
      Uptime:                               15 hours, 2 minutes, 47 seconds
    Slot 2 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 3 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 4 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 5 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:22 PST
      Uptime:                               15 hours, 2 minutes, 49 seconds
    Slot 6 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 10 information:
      State                                 Online    
      Temperature                        24 degrees C / 75 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      128 MB
      Total DDR DRAM                   2048 MB
      Start time:                           2008-12-11 16:53:24 PST
      Uptime:                               15 hours, 2 minutes, 47 seconds
    
  • Issue the CLI show chassis fpc pic-status command. The following example shows an FPC installed in DPC slots 1 and 2:
    user@host> show chassis fpc pic-status
      Slot 0   Online       DPC 40x 1GE R
        PIC 0  Online       10x 1GE(LAN)
        PIC 1  Online       10x 1GE(LAN)
        PIC 2  Online       10x 1GE(LAN)
        PIC 3  Online       10x 1GE(LAN)
      Slot 1   Online       MX FPC Type 3
        PIC 0  Online       1x OC-192 SONET
        PIC 1  Online       1x OC-192 SONET
    

    Note: An FPC takes up two DPC slots when installed on an MX Series router. The slot number corresponds to the lowest numbered DPC slot.

    For further description of the output from the command, see the Junos OS System Basics and Services Command Reference PDF Document.

 

Related Documentation

  • MX Series
  • MX960 Flexible PIC Concentrator (FPC) LEDs
  • Troubleshooting the MX960 FPCs
  • Replacing an MX960 FPC
  • Holding an MX960 FPC
  • Storing an MX960 FPC
 

Published: 2011-09-08

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out