Rolling Back the Integration of a T640 Router
Problem
To return the T640 router to its original
state as a standalone system after you have transferred control to
the TX Matrix router, you can roll back the integration.
During the rollback, traffic passing through the router will be interrupted.
This procedure uses LCC0 as an example.
Solution
 | Warning:
Do not look directly into a fiber-optic array adapter
or a connector at the end of a fiber-optic array cable attached to
an adapter. The fiber optics emit laser light that can damage your
eyes. |
To roll back the integration:
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Take each T640-SIB offline by using one of the following
methods:
- Press and hold the ONLINE/OFFLINE button on the
T640-SIB faceplate until the OK LED is not lit.
- On an external management device connected to the console
or auxiliary port of the TX-CIP, issue the request chassis sib
offline command:
user@host> request chassis sib lcc 0 slot 0
offline
- If the online-expected statement is included
at the [edit chassis lcc number] hierarchy level, delete it:
user@host# delete chassis lcc 0 online-expected
- Issue the commit synchronize command, and ensure
that there are no synchronization errors:
user@host# commit synchronize
- Take the T640 router offline:
user@host> request chassis lcc slot 0 offline
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Remove the control plane connections between the TX-CIPs
and the T-CBs:
- Disconnect the Ethernet cable plugged into the port labeled LCC0 on TX-CIP-0.
- Disconnect the other end of the Ethernet cable plugged
into the port labeled CIP on T-CB-0.
- Disconnect the Ethernet cable plugged into the port labeled LCC0 on TX-CIP-1.
- Disconnect the other end of the Ethernet cable plugged
into the port labeled CIP on T-CB-1.
- Remove the fiber-optic array cable connector from each
T640-SIB adapter. Partially loosen the thumbscrew and captive screw
on the fiber-optic array cable connector. (Use the supplied small
slotted screwdriver to loosen the captive screw.) Alternate between
the thumbscrew and captive screw until the cable connector is removed
from the adapter.
- Remove the dust covers from the dust-free resealable plastic
bag and reinstall them on the fiber-optic array cable connectors.
Align the dust cover with the cable connector and carefully press
them together until they stop. The cover and the cable connector are
keyed to ensure proper mating. Secure the dust cover by tightening
the thumbscrew and captive screw on the connector. (Use the supplied
small slotted screwdriver to tighten the captive screw.)
- Dress the fiber-optic array cables so that they are not
touching or blocking access to T640 router components, and that they
do not drape where people could trip on them.
- Replace each T640-SIB with a SIB. Use the standard replacement
procedure described in the T640 Core Router Hardware Guide
.Do not bring any of the SIBs online.
 | Note:
Ensure that the ejector handle tabs are properly mated inside
their corresponding chassis slots before you tighten the captive screws
on the ejector handles. You might have to close and open the handles
a few times before the tabs catch the slots. |
- Set the M/S switch on each T-CB faceplate to S.
- Set the CHASSIS ID switch on each T-CB faceplate
to 0.
- On an external management device connected to the console
or auxiliary port of the T640-CIP, load the original T640 router configuration.
For example:
user@host# load override t640-config.conf
- If graceful switchover is enabled in the original T640
router configuration, disable it as follows:
user@host# delete chassis redundancy graceful-switchover
- Issue the commit synchronize command and ensure
that there are no synchronization errors:
user@host# commit synchronize
- On an external management device connected to the console
or auxiliary port of T640-CIP-0, reboot the corresponding
Routing Engine in the T640 router:
user@host> request system reboot
- On an external management device connected to the console
or auxiliary port of T640-CIP-1, reboot the corresponding
Routing Engine in the T640 router:
user@host> request system reboot
- Display the status of the SIBs by issuing the show
chassis sibs command on the master Routing Engine:
user@host> show chassis sibs
Slot State Uptime
0 Spare 255 days, 31 minutes, 12 seconds
1 Online 255 days, 31 minutes, 12 seconds
2 Online 255 days, 31 minutes, 12 seconds
3 Online 255 days, 31 minutes, 12 seconds
4 Online 255 days, 31 minutes, 12 seconds
Verify that four SIBs are in the Online state and one
SIB is in the Spare state.
- Delete all statements associated with LCC0 from
the TX Matrix router configuration. To review the T640 router
configuration changes that were merged into the TX Matrix router
configuration, see Creating a Configuration File on the T640 Router for Integration into the Routing Matrix.
 | Note:
You do not need to replace the rear fan tray with the
original one. |
Published: 2011-12-19