The PICS are not functioning normally.
To troubleshoot the PICs:
user@host> show chassis fpc pic-status Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONETFor further description of the output from the command, see the Junos OS System Basics and Services Command Reference.
The PIC slots are numbered from 0 through 3, top to bottom
user@host>show chassis alarmsFor a list of messages that can appear in the output, see Table 1.
Table 1: SONET/SDH Interface Alarm Messages
CLI Message |
|---|
interface-name so-x/x/x - SONET bit error rate defect |
interface-name so-x/x/x - SONET bit error rate fault |
interface-name so-x/x/x - SONET line AIS |
interface-name so-x/x/x - SONET line remote defect indicator |
interface-name so-x/x/x - SONET loss of frame |
interface-name so-x/x/x - SONET loss of light |
interface-name so-x/x/x - SONET loss of pointer |
interface-name so-x/x/x - SONET loss of signal |
interface-name so-x/x/x - SONET path AIS |
interface-name so-x/x/x - SONET path mismatch |
interface-name so-x/x/x - SONET path remote defect indicator |
interface-name so-x/x/x - SONET PLL lock |
interface-name so-x/x/x - SONET remote error indicator |
interface-name so-x/x/x - SONET severely errored frame |
interface-name so-x/x/x - SONET unequipped |