Troubleshooting the T1600 Host Subsystems
Problem
The following alarms and LEDs indicate a problem with
a host subsystem control board and Routing Engine:
- A red alarm indicates that the host subsystem has been
removed.
- A yellow alarm indicates that the host subsystem has failed.
- The red host subsystem FAIL LED on the craft
interface is lit.
- The green host subsystem OK LED on the craft
interface is not lit.
Solution
To troubleshoot the host subsystems:
- Check the LEDs on the faceplate of each control board
and Routing Engine.
- Check the LEDs on the craft interface.
- Use the CLI to check for alarms.
- Standalone T1600 router—Issue the show chassis alarms command to view the alarms.
- T1600 router in a routing matrix—Issue the show chassis alarms
lcc lcc-number command to view the alarms.
In Table 1, the text in the column
labeled ”LCD Message” appears in the display of the craft
interface. The text in the column labeled “CLI Message”
appears in the output from the show chassis alarms command.
Table 1: T1600 Chassis
Alarm Messages for Host Subsystems
Alarm Type | LCD Message | CLI Message |
|---|
Red | Host host-number Removed | Host host-number Removed |
Yellow | Host host-number Failure | Host host-number Failure |
Published: 2011-12-20